赛默飞Thermo CarboPac PA10 Carbohydrate Column离子色谱IC柱
赛默飞Thermo CarboPac PA10 Carbohydrate Column离子色谱IC柱
面议
其他离子色谱柱

赛默飞Thermo CarboPac PA10 Carbohydrate Column离子色谱IC柱

  • 全国
  • 赛默飞
  • 美国
  • 一般经销商
  • 现货
  • 0
  • 0
上海希言科学仪器有限公司
产品特点
离子色谱IC柱
产品描述

For Sensitive Analysis of Mono- and Disaccharides

The Thermo Scientific™ CarboPac™ PA10 column line has been expanded to include a new 0.4 × 250 mm capillary column. As with all CarboPac PA10 columns, the new capillary format is the ideal choice for mono- and disaccharides in foods, drugs and plants.

The CarboPac PA10 is an ideal choice for separations of mono- and disaccharides found in mammalian glycoproteins. Fucose is well resolved from the system void and from protein hydrolysate interferents. The CarboPac PA10 allows oxygen to elute after mannose, eliminating interference with monosaccharides. It is ideal for the analysis of mono- and disaccharides in foods, drugs, and plants, and separates sialic acids with the addition of sodium acetate to the eluent.

  • For the quantification of acidic, neutral, and aminomonosaccharides

  • Simple, isocratic separations

  • Superior selectivity for common monosaccharides compared to the CarboPac PA1

  • No derivatization required

  • Gradient compatible

The CarboPac PA10 is an anion-exchange column designed specifically for high-resolution separations of mono- and disaccharides. Separation is accomplished with a simple isocratic eluent, and detection is accomplished with pulsed amperometric detection (PAD). No derivatization is required.



CarboPac PA10 Column for Monosaccharide and Disaccharide AnalysisSpecifications
DimensionsCarboPac PA10 Analytical Column:
4×250 mm, 2 × 250 mm and 0.4 × 250 mm
CarboPac PA10 Guard Column:
4 × 50 mm, 2 × 50 mm and 0.4 × 50 mm
Maximum operating pressure3500 psi (24.5 MPa)
Temperature range4–55 °C
Recommended operating temperature: ambient
Typical operating conditions1900 psi at 1.0 mL/min (4 mm analytical and guard columns)
Recommended flow rate: 1.0 mL/min (4 mm), 0.25 mL/min (2 mm) or 0.010 mL/min (0.4 mm)
Mobile phase compatibilitypH 0–14; up to 90% of common HPLC solvents.
Avoid anionic detergents and 100% water.
Acetate or hydroxide eluents only.
Resin composition10-µm diameter substrate (ethylvinylbenzene 55% cross-linked with divinylbenzene) agglomerated with 460-nm MicroBeaddifunctional quaternary ammonium ion (5% cross-linked).
Anion-exchange capacityApproximately:
100 µeq/column (4×250 mm analytical column)
25 µeq/column (2×250 mm analytical column)
1 µeq/column (0.4×250 mm analytical column)
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.



Monosaccharide analysis of fetuin hydrolysate sample using the Dionex CarboPac PA10.

High-sensitivity analysis using the CarboPac PA10.

Sialic acid analysis of bovine transferrin on the Dionex CarboPac PA10.

The Dionex CarboPac PA10 resolves mixtures of glycols, sugar alcohols, and carbohydrates in a pharmaceutical formulation.


Analytical Columns
CarboPac PA10 Analytical Column (2 x 250 mm)057180
CarboPac PA10 Analytical Column (4 x 250 mm)046110
CarboPac PA10 Semi-Preparative (9 X 250 mm)SP4216
Guard Columns
CarboPac PA10 Guard Column (2 x 50 mm)057181
AminoTrap Column (2 x 50 mm)SP5578
CarboPac PA10 Guard Column (4 x 50 mm)046115
Amino Trap Column (4 x 50 mm)046122
Borate Trap Column047078
Amino Trap Column (3 x 30 mm)060146


店铺 购物车