Ideal Column for the Separation of Neutral and Acidic Monosaccharides

The CarboPac®PA1 is an anion-exchange column for the separation of mono-, disaccharides, and specific oligosaccharides using an isocratic eluent. Sialic acid analysis has also been demonstrated on this column.

  • General-purpose column for isocratic determination of monosaccharides and disaccharides

  • Detection by pulsed amperometric detection; no derivatization needed

  • Approved for use in a variety of official methods for the analysis of foods

The unique MicroBeadpellicular structure of the CarboPac PA1 resin gives it stability from pH 0–14 at all concentrations of buffer salts. The pellicular resin structure allows excellent mass transfer resulting in fast gradient reequilibration.

The CarboPac PA1 column is used with pulsed amperometric detection; no derivatization is required. Sensitivity on the PA1 is not as high as with the CarboPac PA20 or PA10 for monosaccharide analysis. Thus the CarboPac PA1 is well suited for the analysis of foods for nutritional labeling. The CarboPac PA1 has been approved for use in a number of official methods.


CarboPac PA1 Column for Routine Carbohydrate AnalysisSpecifications
DimensionsCarboPac PA1 Analytical Column:
4×250 mm and 2 × 250 mm
CarboPac PA1 Guard Column:
4 × 50 mm and 2 × 50 mm
CarboPac PA1 Semipreparative Column:
22 × 250 mm
Maximum operating pressure4000 psi (27.9 MPa)
Temperature range4–55 °C
Recommended operating temperature: ambient
Typical operating conditions1500 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min (for 4×250 mm)
Mobile phase compatibilitypH 0–14; up to 2% of common HPLC solvents.
Acetate or hydroxide eluents only.
Resin composition10-µm-diameter substrate (polystyrene 2% cross-linked with divinylbenzene) agglomerated with 500-nm MicroBead quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacityApproximately 100 µeq/column (4×250 mm analytical column)
Column constructionPEEK with 10-32 threaded-ferrule-style end fittings.
All components are nonmetallic.



Chromatographic analysis of purified inulin.

Analysis of mono- and diphosphorylated monosaccharides on the CarboPac PA1.

Isocratic Separation of Sugars Found in Sugarcane Molasses Using the CarboPac PA1 Column.

Analytical Columns
CarboPac PA1 Analytical Column (2 x 250 mm)057178
CarboPac PA1 Analytical Column (4 X 250 mm)035391
CarboPac PA1 Semi-Preparative Column (9 x 250 mm)039686
CarboPac PA1 Semi-Preparative Column (22 x 250 mm)SP2866
Guard Columns
CarboPac PA1 Guard Column (2 x 50 mm)057179
CarboPac PA1 Guard Column (4 x 50 mm)043096
CarboPac PA1 Guard (9 x 50 mm)063501