仪器简介:

1)PC计算机控制,中/英文软件

2)光源等级:BBA级或以上

3)试验温度:25→60℃±2℃

4)辐照度:600-1000W/m2

5)光谱标定范围:400~1100nm或300~900nm

6)执行IEC 60904-3/9, IEC 61215:2005 & Ed.3, IEC 61646:2008等标准

7)附件:

热斑架及Isc分析系统:用于确定遮光位置及遮光面积

辐照度均匀性监控系统:定时扫描

BR-PV-SSS Steady-State Solar Simulator & I-V Measure System
Implementation of standards: IEC 61215:2005 & Ed.3, IEC 61646:2008, UL 1703:2008, IEC 60904.3/9...


 
Test Item Classifications Irr. W/m2 Temp. °C Time / Dose
Precondition 5~5.5KW·h/m2
Light soaking test CCC 600~1000 50 43KW·h/m2
Hot-spot endurance test CCB 700/800~1000 50 1 or 5h
Temperature test 1000 40
Measure of temperature coefficients BBB 1000 20~55↑ Continuous
Performance at low irradiance BBA 200 25
Performance at STC and NOCT BBA 1000 / 800 25 / 20
Maximum power determination BBA 1000 25
 
Main Technical Index:
Spectral Level: Over Class BBA
Effective Irradiation: 2000×1350mm (W×D) or more
Irradiance range: 600~1100W/m2 (full lamps)
Irradiance resolution: 1W/m2
(200W/m2 at low irradiance performance test by using neutral filters or metallicscreen)
Spectral calibration range: 400~1100nm or 300~900nm
Testing temperature: 20~60°C±2°C
Irradiance and temperature control model: PLC programmable controller & PC control
Irradiance measure: by standard cell
I-V measuremen: Isc, Voc, Pm, Imp, Vmp, FF, η, Rs, Rp
Automatically generating and storing I-V-P curve
Xenon lamps matrix is arranged, optimization xenon lamps lighting fixtures angles adjustable.
 

Automatic non-uniformity measurement system (see right):
mechanical transmission system program control,

along the X-Y axis horizontal - longitudinal reciprocating scanning,
data acquisition and processing.
Scanning time can be set.
Measurement point more than 64 (IEC 60904-10).
automatic alarm when more than 5%.
 
Shading plate for hot-spot endurance test:
① Crystalline silicon module
Can satisfy the 0 ~ 100% within 5% increasing or decreasing.
Thin-film module
1~5 pieces cell shaded plates horizontal transmission (see right)
Ordinal sequence covering 1~5 pcs cells,

according to current find Imp×99%, determine shaded plates number.
Electric control displacement shaded plates to suitable current.
Adjust the shaded plates to suitable current.
Data processing system: current automatic collection & analysis

 