型号:530L
品牌:
产地:
型号 | Defender 510 | Defender 520 | Defender 530 | ||
流量范围 | 510L, 5-500ml/min 510M, 50-5000ml/min 510H, 300-30,000ml/min | 520L, 5-500ml/min 520M, 50-5000ml/min 520H, 300-30,000ml/min | 530L, 5-500ml/min 530M, 50-5000ml/min 530H, 300-30,000ml/min | ||
流量精度 | 1% | 1% | 1% | ||
标准的精度 | N/A | N/A | 1.2% | ||
可选 测量 单位 | 流量 | mL/min, L/min, cc/min, cf/min | mL/min, L/min, cc/min, cf/min | mL/min, L/min, cc/min, cf/min | |
标准化 | N/A | N/A | smL/min, sL/min, scc/min, scf/min | ||
温度 | N/A | ℃ H | ℃ H | ||
压力 | N/A | mmHg, PSI, kPa | mmHg, PSI, kPa | ||
温度和压力传感器 | No | Yes | Yes | ||
压力 | N/A | 3.5 mmHg (典型) 7.0 mm (zei大) | 3.5 mmHg (典型) 7.0 mm (zei大) | ||
温度 | N/A | 0.8℃ (典型) 1.3℃ (zei大) | 0.8℃ (典型) 1.3℃ (zei大) | ||
每次读数时间 | 1~15 秒 | ||||
读数模式 (选择从1到100次测量的平均值) | 单次 (手动), 连续或突发模式 | ||||
气体兼容性 | 吴腐蚀性气体、不结露气体, 湿度小于70% | ||||
流动模式 | 压迫或抽吸 | ||||
测量单元 | 一体式 | ||||
AC 交流直流变换器/充电器 | 12V DC, > 250ma, 2.5mm中心位置 | ||||
Battery System电池类型 | 6V 可充电密封铅酸蓄电池,典型工作时间6~8 小时 | ||||
电池运行时间 (5 次/分钟) | 背景光打开3小时, 背景光关闭 8小时 | ||||
压入或抽吸附件 | 软管 | ||||
操作压力 (绝对) | 15 PSI | ||||
显示 | 带背光的图形LCD液晶显示器 | ||||
数据端口 (使用优化软件) | RS-232串口 | ||||
数据电缆 (使用优化软件) | 1 米 Defender校准器至电脑的串口 | ||||
防护箱 | 软质或硬质仪器箱 | ||||
尺寸(H x W x D) | 5.5”x6”x3”/140x150x75mm | ||||
重量 | 29oz/820g | ||||
服从:RoHS-和CE |
| ||||
Size | 5.5"H x 6"W x 3"D 140 mm x 150 mm x 75 mm | |||
Weight | 29 oz. / 820 g | |||
Flow Ranges | ||||
DryCal Defender Low (L) Flow: | 5 to 500 ccm | |||
DryCal Defender Medium (M) Flow: | 50 - 5,000 ccm | |||
DryCal Defender High (H) Flow: | 300 - 30,000 ccm | |||
Accuracy | ||||
Volumetric | ±1.0% | |||
Standardized | ±1.2% | |||
User-Selectable Measurement Units | ||||
Volumetric Flow | mL/min, L/min, cc/min, cf/min | |||
Standarized Flow | smL/min, sL/min, scc/min, scf/min | |||
Pressure | mmHg, PSI, kPa | |||
Temperature | ºC, ºF | |||
Readings | ||||
Approximate Time per Reading | 1-15 seconds | |||
Reading Styles | Single (manual), Continuous or Burst, with averaging function user-selectable from 1 to 100 measurements | |||
Gas Compatibility | Use with non-corrosive, non-condensing, non-combustible gases, less than 70% humidity | |||
Flow Modes | Suction or Pressure | |||
Measurement Cell Style | Integrated | |||
Temperature & Pressure Sensors | In the flow stream Press: 3.5 mmHg (typical), 7.0 mm (max) Temp: 0.8 °C (typical) 1.3 °C (max) | |||
Battery System | ||||
AC Adapter/Charger | 12 DC, >250 ma, 2.5 mm, center positive | |||
Battery | 6V rechargeable, sealed lead-acid, 6-8 hours typical operation | |||
Battery Operational Time | (5 cycles/min), 3 hours backlight on, 8 hours backlight off | |||
Pressure & Suction Fittings | ¼” ID Hose Barb | |||
Display | Backlit graphical LCD | |||
Storage Temperature | 0-70 °C | |||
Ambient Humidity | 0-70% - non-condensing | |||
Operating Pressure | (Absolute) 15 PSI | |||
Warranty | Instrument: 1 year, Battery: 6 months | |||
Data Port | Serial RS-232 (for use with Optimizer Collect software) | |||
Data Cable | 1 meter (Defender Data Port to PC Serial Port) | |||
Protective Case | Soft side or Pelican cases available | |||
Laboratory Accreditation | Backed by ISO 17025 accreditation by NVLAP of NIST | |||
Instrument Certification | RoHS and CE Compliant | |||
Bios Defender 500 Kits Include: One flow cell, Bios Optimizer 110 PC Serial Cable, Software CD, AC Power Adapter/Charger, Plastic Leak Test Caps (2), NIST-Traceable Calibration Certificate and Mini-Manual. |