首页
仪器谱
全内反射荧光显微镜(TIRF)模块
全内反射荧光显微镜(TIRF)模块
全内反射荧光显微镜(TIRF)模块
全内反射荧光显微镜(TIRF)模块
全内反射荧光显微镜(TIRF)模块
面议参考价
全内反射荧光显微镜(TIRF)模块
PIPES指数:7.2用户:应用:

型号型号:TIRF Module

品牌品牌:MCL

产地产地:

北京欧兰科技发展有限公司

青铜会员 青铜会员
核心参数
产地: 美洲
供应商性质: 总代理
产地类别: 进口
产品类型: 倒置荧光显微镜
激发光源: 高压汞灯
价格范围: 100万-150万
仪器结构: 落射式荧光显微镜
荧光显微镜产品推荐
产品描述


Features
  • Easy to switch from epi-illumination to TIR illumination or any angle in between (HILO)

  • Easy to install

  • Easy to align with tip/tilt adjustment of fixed mirror, translatable mirror, and translatable lens

  • Compatible with RM21™ and MicroMirror TIRF


Product Description

Mad City Labs offers a module that converts the RM21™ platform into a total internal reflection fluorescence (TIRF) microscope. The TIRF module makes the transition between epifluorescence, TIRF, and HILO (Highly Inclined and Laminated Optical) microscopy techniques effortless. The TIRF module is a precision aligned add-on component to the RM21™. The TIRF module controls the angle of illumination and the focusing of the excitation beam onto the back focal plane of the objective lens.

The TIRF module enables straightforward adjustment of the excitation beam from along the optical axis for standard epi-illumination of the sample to TIR illumination of the sample, and any angle in between. The figures below illustrate the use of the TIRF module in epi-illumination and TIR illumination.

The excitation beam is reflected from M1, which is attached to a kinematic mount for fine direction control. M1 is fixed and does not translate.  The excitation beam reflects from M2, which can be translated along the beam path using a micrometer.  M2 is also attached to a kinematic mount for fine control of the beam.  L1 focuses the excitation beam onto the back focal plane of the objective lens.  L1 can be adjusted by the kinematic mount and translated axially using a micrometer. The beam translation (shown in the Detailed view of TIRF Module, above) moves the location of the beam on the back focal plane of the objective for epi-illumination/TIR/HILO.


M3 is the TIRF module's exit mirror and is used to direct the TIR exit beam to the TIRF Lock™ module. TIRF Lock™ keeps the sample in the focal plane by maintaining a constant TIRF signal. TIRF Lock™ measures the displacement of the exiting TIR beam and is used with a Z axis sample nanopositioner to keep the sample in focus.

The TIRF module is capable of controlling the full range of sample illumination angles from EPI to TIR.  In practice, the sample illumination angle is adjusted for each experiment to provide the optimized signal-to-noise (SNR) for the available fluorescent signal.  In some experiments, optimal SNR is achieved using HILO illumination, which brings the excitation light in at an angle very close to the critical angle.  The excitation beam thus enters the sample by refraction, but does so at a sharp angle and can achieve better SNR by limiting the excitation of out of focus probes. HILO is one specialized example of the techniques that can be done using the TIRF module for RM21™.



Related Products

 

标准
猜你喜欢
相关产品
店铺
获取底价 电话咨询