首页
仪器谱
奥谱天成 ATR2110 便携式拉曼光谱仪 用于生物科学
98000参考价
奥谱天成 ATR2110 便携式拉曼光谱仪 用于生物科学
奥谱天成_ATR2110_便携式拉曼光谱仪
PIPES指数:7.2用户:应用:

型号型号:ATR2110

品牌品牌:奥谱天成

产地产地:福建

奥谱天成(厦门)光电有限公司

黄金会员 黄金会员
核心参数
产地类别: 国产
仪器种类:
价格范围: 5万-10万
产地: 中国大陆
供应商性质: 生产商
应用场景: 便携台式
拉曼光谱仪产品推荐
产品描述

生物科学是生命科学的基础,学生本科毕业后除在生物科学、生物技术和生态学等领域继续深造外,还可以在医学、农业学科领域继续深造。各高校应依据自身办学定位和人才培养目标,积极应对社会对多样化人才培养的需要,满足学生继续深造和不同的创业、就业志向。积极适应我国经济发展的新常态,树立先进的创新创业教育理念,创新办学机制,改革教学方式和内容,培养创新创业的生力军。

GENERALDESCRIPTION

ATR2110 portable Ramanspectrometer is suitable for field operation. The outstanding reliability makesthe detection result much accurate. The excellent low stray light conditionsthat enable the spectrometer has a wide range of application, especially in thebiochemical analyzer, food safety, pharmaceutical engineering. Themulti-function software facilitated the spectral analysis process inapplication. The remote experiment through internet access makes the bald testitem much easier.

FEATURES

  • linear CCD with TEC cooling;

  • low noise circuit;

  • Powerful embedded software;

  • Fluorescent background eliminate;

  • Peak searching and indicating;

  • 10.1’’ LCD;

  • Android Operation System;

  • USB 2.0;

  • Touch screen  and Keyboard input;

  • Friendly HMI;

  • Battery Endurance > 5 hours;

  • Remote control via LAN;

  • IP67 case;


    APPLICATIONS

  • Biological science

  • Pharmaceuticalengineering

  • Forensic analysis

  • Agriculture and food safety

  • Gemstone

  • Environmentalscience

ATR2110 System


Interface

USB 2.0/LAN

Spectral region

250-2700 cm-1

Spectral resolution

6cm-1  (按美国国标方法测定)

Signal-to-Noise

>400:1 (918 cm-1 of Acetonitrile,10s accumulation, 200mW)

Exciting Laser


Center Wavelength

785nm (+/-1nm)

FWHM

0.1 nm

Output power

≥450 mW


High Reliability

  Figure 3.1 and Figure 3.2 showed thetemperature reliability testing results of fives ATR2110 portable Ramanspectrometers. The testing temperature range was from 5 oC to 40 oC.The spectrometer was kept more than 1 hour at every temperature spots.Acetonitrile was used as the standard sample in the testing. The testingresults were calculated using 918 cm-1 of acetonitrile. Thewavenumber shift was 1 cm-1 or less(as show in Fig. 3.1). The peakintensity variation was less than 10% (as show in Fig. 4).


Temperature range: 5-40 centigradeWavenumber shift: < 1 cm-1

Fig. 3.1 Wavenumber shift results testing from 5 oC to 40oC of fives ATR2110 portable Raman spectrometers

 

Temperature range: 5-40 centigrade

Spectral intensity variation: < 10%

Fig.3.2 Intensity variation testing from 5 oC to 40 oC offives ATR2110 portable Raman spectrometers

4 订购信息

型号波长(nm)功率(mW)波数范围cm-1ATR2110-473473100150-4000ATR2110-532532100150-4000ATR2110-785-27785600250-2700ATR2110-785-40150-4000ATR2110-830830600150-4000ATR2110-10641064600150-4000其他波长可定制


标准
猜你喜欢
店铺
获取底价 电话咨询
AI问答 可以做哪些实验,检测什么? X