赛默飞Thermo OmniPac PCX-100 Cation-Exchange Column
赛默飞Thermo OmniPac PCX-100 Cation-Exchange Column
面议
其它柱附件

赛默飞Thermo OmniPac PCX-100 Cation-Exchange Column

  • 全国
  • 赛默飞
  • 美国
  • 一般经销商
  • 现货
  • 0
  • 1
上海希言科学仪器有限公司
产品特点
液相色谱柱
产品描述

Cation-Exchange Column for the Separation of Low-Molecular-Weight Species

The OmniPac®PCX-100 column is a microporous, solvent-compatible, high-capacity, cation-exchange column designed for the separation of hydrophobic cations, such as amines, drugs, and metabolites.

  • Acid, base, and solvent compatible, pH 0–14

  • Good for organic cations

  • Ideal for the separation of very hydrophobic cations

  • Good for the separation of halogenated cations

The OmniPac PCX-100 column is a specialty cation-exchange column for the separation of low-molecular-weight cations, especially organic analytes. Group 1A and 2A inorganic cations are best separated on theIonPac CS12Acolumn, which is also solvent compatible. The OmniPac PCX-100 column is 100% solvent compatible and should always be run with at least 1% organic solvent in the mobile phase.

The OmniPac PCX-100 is manufactured using a microporous substrate agglomerated with a sulfonated latex bead layer that carries the cation-exchange functionality. The cation-exchange layer is the same as that used in the OmniPac PCX-500 column, and consequently the ion-exchange characteristics of these two columns are identical. The OmniPac PCX-100 column can be used to separate hydrophobic cationic analytes such as amines, anilines, antidepressants, drugs, and metabolites (such as methotrexate and folic acid).


OmniPac PCX-100 Cation-Exchange Column for the Separation of Low-Molecular-Weight Species Specifications
DimensionsOmniPac PCX-100 Analytical Column:
4×250 mm
OmniPac PCX-100 Guard Column:
4 × 50 mm
Maximum operating pressure4000 psi (27.9 MPa)
Recommended operating temperatureAmbient
Typical operating conditions1.0 mL/min with at least 1% organic solvent
Recommended flow rate: 1.0 mL/min
Mobile phase compatibility100% compatible with common organic solvents. Recommended eluents: 1% solvent. Acid to maintain weak bases in the cationic form, salt (e.g., Na+for cation-exchange).
Resin composition8.5-µm-diameter ethylvinylbenzene/divinylbenzene microporous substrate (55% cross-linked) agglomerated with 200-nm MicroBeadsulfonic acid-functionalized latex (5% cross-linked).
Anion-exchange capacity120 µeq/column (4×250 mm analytical column)
Column constructionPEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.


Isocratic Separation of Aromatic Amines.

Separation of a Mixture of Inorganic Cations, Choline, and Acetylcholine by Two Different Chromatographic Modes.


Analytical Columns
OmniPac PCX-100 Analytical Column (4 x 250 mm)042189
Guard Columns
OmniPac PCX-100 Guard Column (4 x 50 mm)042193