赛默飞Thermo Acclaim Mixed-Mode HILIC-1 LC Column
赛默飞Thermo Acclaim Mixed-Mode HILIC-1 LC Column
面议
其它柱附件

赛默飞Thermo Acclaim Mixed-Mode HILIC-1 LC Column

  • 全国
  • 赛默飞
  • 美国
  • 一般经销商
  • 现货
  • 0
  • 0
上海希言科学仪器有限公司
产品特点
液相色谱柱
产品描述

Reversed-Phase and Hydrophilic Interaction Phases Combined on a Single Column

The Acclaim®Mixed-Mode HILIC-1 column utilizes a unique silica-based, mixed-mode stationary phase that combines both reversed-phase (RP) and hydrophilic interaction liquid chromatography (HILIC) properties. The column functional group features a hydrophobic alkyl chain and hydrophilic diol functionality. This combination allows both hydrophobic interaction and hydrophilic interaction to be utilized to optimize separations.

  • Operates in both RP and HILIC modes

  • Retains highly polar molecules

  • Unique selectivity complementary to RP columns

  • Superior performance compared to conventional diol-based columns

  • High efficiency column for high resolution separations

The Acclaim Mixed-Mode HILIC-1 columns consist of 5 μm high-purity, porous, spherical silica with 120 Å-diameter pores bonded with proprietry functional groups, which provide unsurpassed resolution and peak symmetry for a variety of polar and nonpolar molecules.

Wide Range of Applications

The Acclaim Mixed-Mode HILIC-1 column separates both polar and nonpolar molecules with selectivity complementary to RP columns and is suitable for a broad range of applications, including drug metabolites, lipids, polyethylene glycols (PEGs), ethoxylated surfactants and more.


Acclaim Mixed-Mode HILIC-1 ColumnsSpecifications
Particle size:5 µm
Base silica:Spherical, high-purity
Pore size:120 Å
Surface area:300 m2/g
Column chemistry:Proprietary alkyl diol


All the advantages of reversed-phase and HILIC compatibilities in one column.

Note the advantages for reversed-phase and normal-phase modes on a single column.

Separation of phospholipids (lecithin from chicken egg yolk).

Analysis of polyethylene glycols.


Analytical Columns
Acclaim Mixed-Mode HILIC-1, 3µm Analytical (3.0 x 150mm)070090
Acclaim Mixed-Mode HILIC-1, 3µm Analytical (3.0 x 50mm)071912
Acclaim Mixed-Mode HILIC-1, 3µm Analytical (2.1 x 150mm)070091
Acclaim Mixed-Mode HILIC-1, 5 µm (4.6 x 150 mm)066843
Acclaim Mixed-Mode HILIC-1, 5µm (4.6 x 250 mm)066844
Acclaim Mixed-Mode HILIC-1, 5 µm (2.1 x 150 mm)066847
Guard Columns
Acclaim Mixed-Mode HILIC-1, 5 µm Guard Cartrdiges, (4.6 x 10 mm), 2 ea (use V-2 Holder)069706
Acclaim Mixed-Mode HILIC-1, 5µm Guards (3 x 10mm), 2ea, requires holder 069580071913
Acclaim Mixed-Mode HILIC-1, 5µm, Guards (2.1 x 10mm), 2 ea; requires holder 069580069694
Acclaim SST Guard Cartridge Holder V-2069580
Acclaim Guard Kit (Holder and coupler) V-2069707
Guard to Analytical Column Coupler V-2074188