High-Resolution, Strong and Weak Anion-Exchange Columns for the Separation of Proteins

The ProPac®SAX-10 is a nonporous, strong anion-exchange column (quaternary amine functional group). The ProPac WAX-10 column is a weak anion exchanger (tertiary amine functional group). Both are based on a nonporous core particle that provides pressure stability. A hydrophilic layer prevents unwanted secondary interactions and a grafted anion exchange surface provides pH control, selectivity, and fast mass transfer for high efficiency separation, as well as moderate capacity.

  • Unequalled resolution

  • High-efficiency peaks with excellent recovery

  • Higher capacity than other columns based on nonporous particles

  • Useful for characterization and quality control assessment of closely-related protein variants

  • Supports separation of proteins that differ by as little as one amino acid residue

  • Neutral hydrophilic coat that eliminates protein-resin hydrophobic interactions

  • Superior lot-to-lot and column-to-column reproducibility

ProPac SAX-10 and WAX-10 columns can resolve protein isoforms that differ by as little as one charged residue. Differences in selectivity between the WAX-10 and SAX-10 provide flexibility in maximizing resolution of closely related species.

All ProPac columns are manufactured and tested under the strictest specifications, resulting in unmatched column-to-column and lot-to-lot reproducibility. Dionex also offers these columns as lot select packages, containing three columns from one lot or three columns from three different lots, to assist quality control scientists in method validation.


ProPac SAX-10 Strong Anion-Exchange Column for the High-Resolution Separation of Protein IsoformsSpecifications
Maximum operating pressure3000 psi (21 MPa)
Maximum operating conditions60 °C
Recommended operating temperature:<40 °C
Typical operating conditionsUV detection at 1 mL/min
Recommended flow rate: 1 mL/min
Mobile phase compatibilitypH 2–12; 80% compatible with acetonitrile, acetone, methanol.
Compatible with nonionic and zwitterionic detergents.
Incompatible with anionic detergents.
Resin composition10-µm-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the quaternary ammonium functional groups.
Anion-exchange capacity< 100 µg protein on-column, depending upon the protein
(4×250 mm analytical column)
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
ProPac WAX-10 Weak Anion-Exchange Column for the High-Resolution Analysis of Protein VariantsSpecifications
Maximum operating pressure3000 psi (21 MPa)
Maximum operating temperature60 °C
Recommended operating temperature:<40 °C
Typical operating conditionsUV detection at 1 mL/min
Recommended flow rate: 1 mL/min
Mobile phase compatibilitypH 2–12; 80% compatible with acetonitrile, acetone, methanol.
Compatible with nonionic and switterionic detergents.
Incompatible with anionic detergents.
Resin composition10-µm-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the tertiary amine functional groups.
Anion-exchange capacity< 100 µg protein on-column, depending upon the protein
(4×250 mm analytical column)
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.



Resolution of phosphorylation variants of ovalbumin.

Effect of sialylation on transferrin chromatography.

Profiling dairy milk caseins.

The ProPac WAX shows high selectivity for proteins in this separation of carbonic anhydrase.


SAX Analytical Columns
ProPac SAX-10 Analytical Column (2 x 250 mm)063448
ProPac SAX-10 Analytical Column (4 x 250 mm)054997
ProPac SAX-10HT Analytical Column (4 x 50 mm)078990
ProPac SAX-10 Lot Select Column Set (4 x 250 mm) (1 Lot of Resin)SP5729
ProPac SAX-10 Lot Select Column Set (4 x 250 mm) (3 Lots of Resin)SP5730
ProPac SAX-10 Semi-Preparative Column (9 x 250 mm)063703
ProPac SAX-10 Semi-Preparative Column (22 x 250 mm)SP5594
WAX Analytical Columns
ProPac WAX-10 Analytical Column (2 x 250 mm)063464
ProPac WAX-10 Analytical Column (4 x 250 mm)054999
ProPac WAX-10 Lot Select Column Set (4 x 250 mm) (1 Lot of Resin)SP5731
ProPac WAX-10 Lot Select Column Set (4 x 250 mm) (3 Lots of Resin)SP5732
ProPac WAX-10 Semi-Preparative Column (9 x 250 mm)063707
ProPac WAX-10 Semi-Preparative Column (22 x 250 mm)SP5598
WAX Guard Columns
ProPac WAX-10G Guard Column (2 x 50 mm)063470
ProPac WAX-10G Guard Column (4 x 50 mm)055150
SAX Guard Columns
ProPac SAX-10G Guard Column (2 x 50 mm)063454
ProPac SAX-10G Guard Column (4 x 50 mm)054998


店铺 购物车
加入购物车
咨询 拨号
AI问答 配套的仪器设备? X