11.040.70 眼科设备 标准查询与下载



共找到 1851 条与 眼科设备 相关的标准,共 124

Ophthalmic optics-Spectacle lenses-Fundamental requirements for uncut finished lenses

ICS
11.040.70
CCS
发布
2015-12-23
实施

Ophthalmic optics-Contact lens care products-Guidelines for determination of shelf-life

ICS
11.040.70
CCS
发布
2015-12-23
实施

Ophthalmic optics-Contact lens care products-Guidelines for determination of shelf-life

ICS
11.040.70
CCS
发布
2015-12-23
实施

Ophthalmic optics-Spectacle lenses-Fundamental requirements for uncut finished lenses

ICS
11.040.70
CCS
发布
2015-12-23
实施

Ophthalmic optics-Contact lenses and contact lens care products-Fundamental requirements

ICS
11.040.70
CCS
发布
2015-12-23
实施

ISO 15004-1:2006 specifies fundamental requirements for non-invasive, active and non-active ophthalmic instruments. ISO 15004-1:2006 is also applicable to low-vision aids and tonometers, but not to other ophthalmic instruments which are used in contact with the globe of the eye. ISO 15004-1:2006 is not applicable to operation microscopes, endoscopes and devices intended for laser investigation or laser treatment of the eye.

Ophthalmic instruments -- Fundamental requirements and test methods -- Part 1: General requirements applicable to all ophthalmic instruments

ICS
11.040.70
CCS
发布
2015-12-21
实施

ISO 15004-2:2007 specifies fundamental requirements for optical radiation safety for ophthalmic instruments and is applicable to all ophthalmic instruments that direct optical radiation into or at the eye and for which there is a specific light hazards requirement section within their respective International Standards. It is also applicable to all new and emerging ophthalmic instruments that direct optical radiation into or at the eye. ISO 15004-2:2007 does not apply to radiation that is in excess of limits specified in ISO 15004 and that is intended for treatment of the eye. ISO 15004-2:2007 classifies ophthalmic instruments into either Group 1 or a Group 2 in order to distinguish instruments that are non-hazardous from those that are potentially hazardous.

Ophthalmic instruments -- Fundamental requirements and test methods -- Part 2: Light hazard protection

ICS
11.040.70
CCS
发布
2015-12-21
实施

ISO 15752:2010 specifies optical radiation safety aspects of endoilluminator light sources and endoilluminator light guides which are used to illuminate the interior of the eye during ocular surgery.

Ophthalmic instruments -- Endoilluminators -- Fundamental requirements and test methods for optical radiation safety

ICS
11.040.70
CCS
发布
2015-12-21
实施

ISO 10342:2010 together with ISO 15004‑1, specifies requirements and test methods for eye refractometers using an objective measuring principle. It is limited to the measurement of spherocylindrical refractive error. ISO 10342:2010 takes precedence over ISO 15004‑1, if differences exist.

Ophthalmic instruments -- Eye refractometers

ICS
11.040.70
CCS
发布
2015-12-21
实施

ISO 18369-3:2006 specifies the methods for measuring the physical and optical properties of contact lenses specified in ISO 18369-2, i.e. radius of curvature, back vertex power, diameter, thickness, inspection of edges, inclusions and surface imperfections, and determination of spectral and luminous transmittances. ISO 18369-3:2006 also specifies the equilibrating solution, standard saline solution, for testing of contact lenses.

Ophthalmic optics -- Contact lenses -- Part 3: Measurement methods

ICS
11.040.70
CCS
发布
2015-12-21
实施

  Scope is not provided for this standard

Ophthalmic optics -- Spectacle frames and sunglasses electronic catalogue and identification -- Part 3: Technical information

ICS
11.040.70
CCS
发布
2015-12-21
实施

  Scope is not provided for this standard

Ophthalmic optics -- Contact lens care products -- Antimicrobial preservative efficacy testing and guidance on determining discard date

ICS
11.040.70
CCS
发布
2015-12-21
实施

  Scope is not provided for this standard

Ophthalmic optics -- Mounted spectacle lenses

ICS
11.040.70
CCS
发布
2015-12-21
实施

The purpose of ISO/TR 28980:2007 is to explain the changes relating to power measurements in the revised editions of ISO 8980-1 and ISO 8980-2. In order to illustrate the issues raised, an inter-laboratory power measurement study was conducted on ten different lenses measured by nine organizations worldwide. Twenty-five focimeters of different types were used. The test lenses were spherically powered allyl diglycol carbonate (ADC) hard resin lenses surfaced to -4,00 D, -2,00 D, 0,00 D, +2,00 D, and +4,00 D, each with an addition power of 2,50 D. Five were D28 bifocals and five were progressive power lenses. The measurements were front distance power, front near power, back distance power and back near power, for each lens and for each focimeter used. Each lens was measured nine times: five measurements taken without repositioning the lens and four measurements taken with the lens repositioned each time. The assessed parameters were divided in three categories: discrepancies due to focimeter design and measurement methods; systematic errors; random errors. For each parameter, experimental results are given, as well as theoretical ones when needed. Measurement data include front distance portion power, front near portion power, back distance portion power and back near portion power. Unless stated otherwise, in order to show relevant information, the results shown are for the D28 bifocals when no different behaviour was found for the progressive power lenses.

Ophthalmic optics -- Spectacle lenses -- Parameters affecting lens power measurement

ICS
11.040.70
CCS
发布
2015-12-21
实施

ISO 18369-4:2006 specifies the methods of testing the physicochemical properties of contact lens materials. These are extraction, rigid lens flexure and breakage, oxygen permeability, refractive index and water content.

Ophthalmic optics -- Contact lenses -- Part 4: Physicochemical properties of contact lens materials

ICS
11.040.70
CCS
发布
2015-12-21
实施

  Scope is not provided for this standard

Ophthalmic optics -- Spectacle frames and sunglasses electronic catalogue and identification -- Part 2: Commercial information

ICS
11.040.70
CCS
发布
2015-12-21
实施

ISO 10343:2014 specifies requirements and test methods for continuously or digitally indicating ophthalmometers. Certain types of ophthalmometer have sufficient resolution and range to adequately measure the radii of curvature of contact lenses. It is assumed that the local corneal front surface and both contact lens surfaces are spherical or toroidal.

Ophthalmic instruments – Ophthalmometers

ICS
11.040.70
CCS
发布
2015-12-21
实施

ISO 14534:2011 specifies safety and performance requirements for contact lenses, contact lens care products, and other accessories for contact lenses. ISO 14534:2011 does not specify electrical safety and electromagnetic compatibility considerations that might arise from the use of electrical equipment in conjunction with contact lenses or contact lens care products.

Ophthalmic optics -- Contact lenses and contact lens care products -- Fundamental requirements

ICS
11.040.70
CCS
发布
2015-12-21
实施

ISO 18369-2:2012 specifies the tolerance limits of the principal optical and physical parameters of rigid, soft and rigid scleral contact lenses.

Ophthalmic optics -- Contact lenses -- Part 2: Tolerances

ICS
11.040.70
CCS
发布
2015-12-21
实施

This International Standard specifies minimum requirements for instruments and systems that fall into the class of corneal topographers (CTs). It also specifies tests and procedures to verify that a system or instrument complies with this International Standard and thus qualifies as a CT according to this International Standard. It also specifies tests and procedures that allow the verification of capabilities of systems that are beyond the minimum requirements for CTs. This International Standard defines terms that are specific to the characterization of the corneal shape so that they may be standardized throughout the field of vision care. This International Standard is applicable to instruments, systems and methods that are intended to measure the surface shape of the cornea of the human eye. NOTE The measurements can be of the curvature of the surface in local areas, three-dimensional topographical measurements of the surface or other more global parameters used to characterize the surface. It is not applicable to ophthalmic instruments classified as ophthalmometers.

Ophthalmic instruments — Corneal topographers

ICS
11.040.70
CCS
发布
2015-12-21
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号