13.220.50 建筑材料和构件的阻燃性 标准查询与下载



共找到 1303 条与 建筑材料和构件的阻燃性 相关的标准,共 87

This part of ISO 834 specifies a method for testing fire protection systems applied to structural steel members used in buildings as beams, columns, or tension members. This part of ISO 834 is intended for use in conjunction with the assessment protocol described in ISO 834-11. It applies to steel sections (including hollow sections) and only considers sections without openings in the web. Results from analysis of I or H sections are directly applicable to angles, channels, and T-sections for the same section factor, whether used as individual members, e.g. bracing, or part of a fabricated structural system such as a steel truss construction. This part of ISO 834 does not apply to solid bar, rod, or concrete-filled hollow sections. This part of ISO 834 describes the fire test procedures that specify the tests which should be carried out to determine the ability of the fire protection system to remain sufficiently coherent and in position for a well-defined range of deformations, furnace, and steel temperatures, such that the efficacy of the fire protection system is not significantly impaired, and to provide data on the thermal characteristics of the fire protection system when exposed to the standard temperature/time curve specified in ISO 834-1. In special circumstances, where specified in National Building Regulations, there can be a requirement to subject reactive fire protection materials to a smouldering curve. The test and the requirements for its use are described in Annex G. This part of ISO 834 is applicable to both passive and reactive fire protection systems as defined in the terms and definitions, which are installed or applied in such a way that they remain in place for the intended duration of fire exposure. The fire test methodology makes provision for the collection and presentation of data which is then used as direct input into ISO 834-11 to determine the limits of direct application to steel sections of various shapes, sizes, and fire resistance periods.

Fire resistance tests -- Elements of building construction -- Part 10: Specific requirements to determine the contribution of applied fire protection materials to structural steel elements

ICS
13.220.50
CCS
发布
2016-12-22
实施

1.1 This fire-test-response standard describes the measurement of surface flammability of materials. It is not intended for use as a basis of ratings for building code purposes (see Appendix X1). 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.5 Fire testing of products and materials is inherently hazardous, and adequate safeguards for personnel and property shall be employed in conducting these tests. This test method may involve hazardous materials, operations, and equipment. Specific information about hazard is given in Section . NOTE 1—There is no similar or equivalent ISO standard.

Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source

ICS
13.220.50
CCS
发布
2016-12-15
实施

External fire exposure to roofs in combination with photovoltaic (PV) arrays - Test method(s)

ICS
13.220.50
CCS
发布
2016-12-01
实施

Reaction-to-fire tests - Heat release, smoke production and mass loss rate - Part 4: Measurement of low levels of heat release

ICS
13.220.50
CCS
发布
2016-12-01
实施

Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services; German version EN 13501-2:2016

ICS
13.220.50
CCS
P16
发布
2016-12
实施

Fire classification of construction products and building elements - Part 4: Classification using data from fire resistance tests on components of smoke control systems; German version EN 13501-4:2016

ICS
13.220.50
CCS
P16
发布
2016-12
实施

Method of non-combustibility test of building products

ICS
13.220.50
CCS
发布
2016-11-24
实施

Waterproof admixture for concrete

ICS
13.220.50
CCS
发布
2016-11-24
实施

Waterproofing admixture for concrete

ICS
13.220.50
CCS
发布
2016-11-24
实施

Method of non-combustibility test of building products

ICS
13.220.50
CCS
发布
2016-11-24
实施

1.1 This fire-test-response test method covers the determination under specified laboratory conditions of combustion characteristics of building materials. 1.2 Limitations of this fire-test response test method are shown below. 1.2.1 This test method does not apply to laminated or coated materials. 1.2.2 This test method is not suitable or satisfactory for materials that soften, flow, melt, intumesce or otherwise separate from the measuring thermocouple. 1.2.3 This test method does not provide a measure of an intrinsic property. 1.2.4 This test method does not provide a quantitative measure of heat generation or combustibility; it simply serves as a test method with selected (end point) measures of combustibility. 1.2.5 The test method does not measure the self-heating tendencies of materials. 1.2.6 In this test method materials are not being tested in the nature and form used in building applications. The test specimen consists of a small, specified volume that is either (1) cut from a thick sheet; (2) assembled from multiple thicknesses of thin sheets; or (3) placed in a container if composed of granular powder or loose-fiber materials. 1.2.7 Results from this test method apply to the specific test apparatus and test conditions and are likely to vary when changes are made to one or more of the following: (1) the size, shape, and arrangement of the specimen; (2) the distribution of organic content; (3) the exposure temperature; (4) the air supply; (5) the location of thermocouples. 1.3 This test method includes two options, both of which use a furnace to expose test specimens of building materials to a temperature of 750°C (1382°F). 1.3.1 The furnace for the apparatus for Option A consists of a ceramic tube containing an electric heating coil, and two concentric vertical refractory tubes. 1.3.2 The furnace for the apparatus for Option B (Test Method E2652) consists of an enclosed refractory tube surrounded by a heating coil with a cone-shaped airflow stabilizer. 1.4 This test method references notes and footnotes that provide explanatory information. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of this test method. 1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.6 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire-hazard or fire-risk assessment of the materials, products, or assemblies under actual fire conditions. 1.7 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C

ICS
13.220.50
CCS
发布
2016-11-01
实施

Standard Test Methods for Fire Tests of Roof Coverings

ICS
13.220.50
CCS
发布
2016-10-01
实施

Method of ignitability test method of building products subjected to direct impingement of flame of single flame source

ICS
13.220.50
CCS
发布
2016-09-19
实施

Method of ignitability test method of building products subjected to direct impingement of flame of single flame source

ICS
13.220.50
CCS
发布
2016-09-19
实施

Method of ignitability test of building products subjected to direct impingement of flame of multi-flame source test

ICS
13.220.50
CCS
发布
2016-09-19
实施

Method of ignitability test of building products subjected to direct impingement of flame of multi-flame source test

ICS
13.220.50
CCS
发布
2016-09-19
实施

Testing method for incombustibility of internal finish material and element of buildings

ICS
13.220.50
CCS
发布
2016-09-19
实施

Testing method for incombustibility of thin materials for buildings

ICS
13.220.50
CCS
发布
2016-09-19
实施

Method of ignitability test of building products subjected to direct impingement of flame of multi-flame source test

ICS
13.220.50
CCS
发布
2016-09-19
实施

Method of ignitability test method of building products subjected to direct impingement of flame of single flame source

ICS
13.220.50
CCS
发布
2016-09-19
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved