13.220.50 建筑材料和构件的阻燃性 标准查询与下载



共找到 1303 条与 建筑材料和构件的阻燃性 相关的标准,共 87

Testing method for incombustibility of thin materials for buildings

ICS
13.220.50
CCS
发布
2016-09-19
实施

Testing method for incombustibility of thin materials for buildings

ICS
13.220.50
CCS
发布
2016-09-19
实施

Method of ignitability test of building products subjected to direct impingement of flame of multi-flame source test

ICS
13.220.50
CCS
发布
2016-09-19
实施

Fire classification of construction products and building elements. Classification using data from fire resistance tests, excluding ventilation services

ICS
13.220.50
CCS
P16
发布
2016-07-31
实施
2016-07-31

Fire classification of construction products and building elements. Classification using data from fire resistance tests on components of smoke control systems

ICS
13.220.50
CCS
P16
发布
2016-07-31
实施
2016-07-31

4.1 This test method is intended to provide only comparative measurements of surface flame spread and smoke density measurements with that of select grade red oak and fiber-cement board surfaces under the specific fire exposure conditions described herein. 4.2 This test method exposes a nominal 24-ft (7.32-m) long by 20-in. (508-mm) wide specimen to a controlled air flow and flaming fire exposure adjusted to spread the flame along the entire length of the select grade red oak specimen in 51/2 min. 4.3 This test method does not provide for the following: 4.3.1 Measurement of heat transmission through the tested surface. 4.3.2 The effect of aggravated flame spread behavior of an assembly resulting from the proximity of combustible walls and ceilings. 4.3.3 Classifying or defining a material as noncombustible, by means of a flame spread index by itself. 1.1 This fire-test–response standard for the comparative surface burning behavior of building materials is applicable to exposed surfaces such as walls and ceilings. The test is conducted with the specimen in the ceiling position with the surface to be evaluated exposed face down to the ignition source. The material, product, or assembly shall be capable of being mounted in the test position during the test. Thus, the specimen shall either be self-supporting by its own structural quality, held in place by added supports along the test surface, or secured from the back side. 1.2 The purpose of this test method is to determine the relative burning behavior of the material by observing the flame spread along the specimen. Flame spread and smoke developed index are reported. However, there is not necessarily a relationship between these two measurements. 1.3 The use of supporting materials on the underside of the test specimen has the ability to lower the flame spread index from those which might be obtained if the specimen could be tested without such support. These test results do not necessarily relate to indices obtained by testing materials without such support. 1.4 Testing of materials that melt, drip, or delaminate to such a degree that the continuity of the flame front is destroyed, results in low flame spread indices that do not relate directly to indices obtained by testing materials that remain in place. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of the standard.

Standard Test Method for Surface Burning Characteristics of Building Materials

ICS
13.220.50
CCS
发布
2016-07-01
实施

This European Standard specifies the procedure for classification of construction products and building elements using data from fire resistance and smoke leakage tests which are within the direct field of application of the relevant test method. Classification on the basis of extended application of test results is also included in the scope of this European Standard. This European Standard deals with: a) loadbearing elements without a fire separating function:- walls; - floors; - roofs; - beams; - columns; - balconies; - walkways; - stairs. b) loadbearing elements with a fire separating function, with or without glazing, services and fixtures; - walls; - floors; - roofs; - raised floors. c) products and systems for protecting elements or parts of the works; - ceilings with no independent fire resistance; - fire protective coatings, claddings and screens; d) non-loadbearing elements or parts of works, with or without glazing, services and fixtures; - partitions; - facades (curtain walls) and external walls; - ceilings with independent fire resistance; - raised floors; - fire doors and shutters and their closing devices; - smoke control doors; - conveyor systems and their closures; - penetration seals; - linear joint seals; - service ducts and shafts; - chimneys. e) wall and ceiling coverings with fire protection ability. f) lift landing doors which are tested according to EN 81-58 are excluded from this European Standard. Lift landing doors which are tested in accordance with EN 1634-1, are classified in accordance with 7.5.5. Relevant test methods which have been prepared for these elements are listed in Clauses 2 and 7.

Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services

ICS
13.220.50
CCS
Q83
发布
2016-06
实施

This European Standard specifies the procedure for classification of components of smoke control systems, using data from fire resistance tests which are within the field of application of the relevant test methods. Classification on the basis of extended application of test results is also included in the scope of this European Standard. Products covered by this European Standard are:- smoke control ducts; smoke control dampers; smoke barriers; powered smoke and heat control ventilators (fans), including connectors; natural smoke and heat exhaust ventilators. Relevant documents which include the relevant test methods which have been prepared for these products are listed in Clause 2.

Fire classification of construction products and building elements - Part 4: Classification using data from fire resistance tests on components of smoke control systems

ICS
13.220.50
CCS
Q83
发布
2016-06
实施

What is BS EN 16733 -  Smouldering propensity of building products about ?   BS EN 16733 is a European Standard that discusses the reaction to fire tests for building products.   BS EN 16733 deals with reaction to fire tests that are intended for all building products which specifies a test method to determine the propensity (ability) of a building product to smoulder continuously when exposed to an open flame under the influence of natural convective airflow.   Who is BS EN 16733 - Smouldering propensity of building products for ?  

Reaction to fire tests for building products. Determination of a building product's propensity to undergo continuous smouldering

ICS
13.220.50
CCS
发布
2016-05-31
实施
2016-05-31

This part of ISO 3008 specifies the test method for determining the fire resistance of horizontally oriented door and shutter assemblies which may be exposed to a fire from the underside. It is applicable to all types of door and shutter assemblies installed in a horizontal orientation within floor or roof assemblies requiring fire-resistance ratings in buildings. The test method allows for the measurement ofintegrity and, ifrequired, the measurement ofradiation and thermal insulation. In addition, this test method includes measurement ofthe load-carrying ability ofthe test specimens subjected to a standard fire-resistance test.

Fire resistance tests — Part 3: Door and shutter assemblies horizontally oriented

ICS
13.220.50
CCS
发布
2016-05-02
实施

Reaction to fire tests - Room corner test for wall and ceiling lining products - Part 1: Test method for a small room configuration

ICS
13.220.50
CCS
P16
发布
2016-02
实施

5.1 The fire performance of a material or product is affected by a combination of its fire-test-response characteristics. Two of the most commonly determined fire-test-response characteristics of cushioning materials are the surface flammability, in accordance with Test Method D3675, and the specific optical density of smoke, in accordance with Test Method E662. 5.2 Cushioning materials used in upholstery applications are potentially exposed to leaching of the active ingredients due to (1) water solubility of the treating agents or (2) exposure to high humidity. 5.3 In view of the importance that the fire performance of the cushioning materials used in upholstery applications remain constant throughout their intended service life, this test method provides a means to test for the potential change in two fire-test-response characteristics due to leaching. 1.1 This fire-test-response test method covers a procedure for leaching cushioning materials with water and determining changes in two specific fire-test-response characteristics: (1) the surface flammability, in accordance with Test Method D3675, and (2) the specific optical density of smoke generated, in accordance with Test Method E662. 1.2 In view of the wide variation in potential service conditions, it is likely that results of this leaching test will not give a direct correlation with service performance for all applications. However, the test method yields comparative data on which to base judgments as to expected service of cushioning materials and is useful in research and development work. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 7. 1.6 Fire testing is ......

Standard Test Method for Determining Changes in Fire-Test-Response Characteristics of Cushioning Materials After Water Leaching

ICS
13.220.50
CCS
发布
2016
实施

  Scope is not provided for this standard

Reaction to fire tests -- Measurement of material properties using a fire propagation apparatus

ICS
13.220.50
CCS
发布
2015-12-21
实施

  Scope is not provided for this standard

Fire-resistance tests -- Part 2: Lift landing door assemblies

ICS
13.220.50
CCS
发布
2015-12-21
实施

  Scope is not provided for this standard

Standard test method for measuring the heat release rate of low flammability mattresses and mattress sets

ICS
13.220.50
CCS
发布
2015-12-21
实施

  Scope is not provided for this standard

Standard tests for measuring reaction-to-fire of products and materials -- Their development and application

ICS
13.220.50
CCS
发布
2015-12-21
实施

Standard Test Method for Surface Burning Characteristics of Building Materials

ICS
13.220.50
CCS
发布
2015-12-15
实施

Electric cables - Fire resistance test for unprotected electric cables (P classification))

ICS
13.220.50
CCS
发布
2015-12-01
实施

Generation of thermal decomposition products from materials for their analytic-toxicological testing - Part 2: Thermal decomposition method

ICS
13.220.50
CCS
P16;Q04
发布
2015-12
实施

Generation of thermal decomposition products from materials for their analytic-toxicological testing - Part 1: Decomposition apparatus and determination of test temperature

ICS
13.220.50
CCS
P16;Q04
发布
2015-12
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved