13.220.50 建筑材料和构件的阻燃性 标准查询与下载



共找到 1304 条与 建筑材料和构件的阻燃性 相关的标准,共 87

Generation of thermal decomposition products from materials for their analytic-toxicological testing - Part 4: Thermal decomposition method for liquids

ICS
13.220.50
CCS
P16;Q04
发布
2015-12
实施

Generation of thermal decomposition products from materials for their analytic-toxicological testing - Part 1: Decomposition apparatus and determination of test temperature

ICS
13.220.50
CCS
P16;Q04
发布
2015-12
实施

Fire resistance tests for service installations - Part 2: Fire dampers

ICS
13.220.50
CCS
发布
2015-10-30
实施
2015-10-30

Method of fire resistance test for elements of building construction — Specific requirements for loadbearing vertical separating elements

ICS
13.220.50
CCS
发布
2015-10-13
实施

Method of fire resistance test for elements of building construction — Specific requirements for non-loadbearing vertical separating elements

ICS
13.220.50
CCS
发布
2015-10-13
实施

Method of fire resistance test for elements of building construction — Specific requirements for loadbearing vertical separating elements

ICS
13.220.50
CCS
发布
2015-10-13
实施

Method of fire resistance test for elements of building construction — Specific requirements for non-loadbearing vertical separating elements

ICS
13.220.50
CCS
发布
2015-10-13
实施

This part of ISO 834 specifies the procedures to be followed for determining the fire resistance of beams, when tested on their own. Beams are normally tested with their underside and two vertical sides fully exposed to heating. However, when the exposure is from four sides or less than three sides, appropriate exposure conditions are necessary. Beams which are part of a floor construction are tested with the floor construction as described in ISO 834-5 and are subject to evaluation of integrity and insulation. The application of this test to other untested forms of construction is acceptable when the construction complies with the direct field of application as given in this part of ISO 834 or when subjected to an extended application analysis in accordance with ISO/TR 12470. Since ISO/TR 12470 gives only general guidelines, specific extended application analyses are to be performed only by persons expert in fire-resistant constructions. General guidance on this test method is given in annex A.

Fire-resistance tests -- Elements of building construction -- Part 6: Specific requirements for beams

ICS
13.220.50
CCS
发布
2015-09-03
实施

This part of ISO 834 specifies a test method for determining the fire resistance of various elements of construction when subjected to standard fire exposure conditions. The test data thus obtained will permit subsequent classification on the basis of the duration for which the performance of the tested elements under these conditions satisfies specified criteria.

Fire-resistance tests -- Elements of building construction -- Part 1: General requirements

ICS
13.220.50
CCS
发布
2015-09-03
实施

This International Standard specifies a method of test for determining the non-combustibility performance, under specified conditions, of homogeneous products and substantial components of non-homogeneous products. Information on the precision of the test method is given in Annex A.

Reaction to fire tests for products -- Non-combustibility test

ICS
13.220.50
CCS
发布
2015-09-03
实施

This part of ISO 5660 specifies a small-scale method for assessing the dynamic smoke production rate of essentially flat specimens exposed to controlled levels of radiant heating under well-ventilated conditions with or without an external igniter. The rate of smoke production is calculated from measurement of the attenuation of a laser light beam by the combustion product stream. Smoke obscuration is recorded for the entire test, regardless of whether the specimen is flaming or not. The measurement system prescribed by this part of ISO 5660 is an extension of the apparatus described in ISO 5660-1. Therefore, this part of ISO 5660 is used in conjunction with ISO 5660-1.

Reaction-to-fire tests -- Heat release, smoke production and mass loss rate -- Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement)

ICS
13.220.50
CCS
发布
2015-09-03
实施

This International Standard specifies a method for the determination of the gross heat of combustion (QPCS) of products at constant volume in a bomb calorimeter. Annex A describes the calculation of the net heat of combustion (QPCI) when required. Information on the precision of the test method is given in Annex B.

Reaction to fire tests for products -- Determination of the gross heat of combustion (calorific value)

ICS
13.220.50
CCS
发布
2015-09-03
实施

This Technical Report provides a commentary that explains the general philosophy and factors on which the test specified in Part 1 of ISO 5925 has been designed, to describe the limitations of its application and to provide some general guidance for those who use the result of the test. Smoke control-door and shutter assemblies can be used as part of a smoke containment strategy for the purposes of life safety or property protection.

Fire tests -- Smoke-control door and shutter assemblies -- Part 2: Commentary on test method and the applicability of test conditions and the use of test data in a smoke containment strategy

ICS
13.220.50
CCS
发布
2015-09-03
实施

This part of ISO 834 specifies the procedures to be followed for determining the fire resistance of non-loadbearing vertical separating elements when exposed to heating on one face. The test is neither appropriate for the evaluation of curtain walls (non-loadbearing external walls suspended from the ends of floor slabs) nor for walls containing doors or glazing. For tests of walls containing doors refer to ISO 3008[2]. For tests of walls containing glazing refer to ISO 3009[3]. The application of this test to other untested forms of construction is acceptable when the construction complies with the direct field of application as given in this document or when it is subjected to a field of extended application analysis in accordance with ISO/TR 12470[4]. NOTE Since ISO/TR 12470 gives only general guidelines, specific extended application analyses are to be performed only by persons expert in fire resistant constructions.

Fire-resistance tests -- Elements of building construction -- Part 8: Specific requirements for non-loadbearing vertical separating elements

ICS
13.220.50
CCS
发布
2015-09-03
实施

This part of ISO 9705 provides guidance on ISO 9705:1993. It describes the technical background of the test and gives information which may be used for determining a testing procedure for a specific scenario, or how results can be utilized in a total hazard analysis for the specified scenario.

Reaction-to-fire tests -- Full-scale room tests for surface products -- Part 2: Technical background and guidance

ICS
13.220.50
CCS
发布
2015-09-03
实施

This Technical Specification provides guidance on flame spread tests. It describes the principles of flame spread and classifies different flame-spread mechanisms.

Reaction to fire tests -- Spread of flame -- Part 1: Guidance on flame spread

ICS
13.220.50
CCS
发布
2015-09-03
实施

1.1 This part of ISO 5658 specifies an intermediate-scale method of test for measuring the vertical spread (upward and downward) of flame over a specimen of a product orientated in the vertical position. A measure of lateral spread can also be obtained. It provides data suitable for comparing the performance of materials, composites or assemblies, which are used as the exposed surfaces of walls or other vertically orientated products in construction applications. Some products with profiled surfaces can also be tested with a modified procedure representative of the end-use conditions of the product. 1.2 Upward flame spread is not limited to surfaces which are vertical. It is recognized that an enhanced form of upward, wind-aided flame spread can also occur on surfaces at an angle greater than 20° from the horizontal without any external ventilation. This type of flame spread can occur in both planar sloping surfaces and stepped surfaces such as stairs. Flame spread in these situations can become very rapid and can cause serious problems in escape ways such as staircases. When assessing stepped or sloping surface materials, it may be more appropriate to use a vertical flame spread test rather than a test in which the specimen is horizontal. 1.3 This part of ISO 5658 is applicable to the measurement and description of the properties of materials, products, composites or assemblies in response to radiative heat in the presence of non-impinging pilot flames under controlled laboratory conditions. The heat source may be considered to represent a single burning item such as a wastepaper bin or an upholstered chair within an enclosure, and this scenario would generally be considered to apply during the early developing stage of a fire (see ISO/TR 11696-1 and ISO/TR 11696-2). This part of ISO 5658 should not be used alone to describe or appraise the fire hazard or fire risk of materials, products, composites or assemblies under actual fire conditions.

Reaction to fire tests -- Spread of flame -- Part 4: Intermediate-scale test of vertical spread of flame with vertically oriented specimen

ICS
13.220.50
CCS
发布
2015-09-03
实施

This part of ISO 834 specifies the procedures to be followed for determining the fire resistance of loadbearing vertical separating elements when exposed to heating on one face. The application of this test to other untested forms of construction is acceptable when the construction complies with the direct field of application as given in this part of ISO 834 or when subjected to an extended application analysis in accordance with ISO/TR 12470. Since ISO/TR 12470 gives only general guidelines, specific extended application analyses are to be performed only by persons expert in fire-resistant constructions.

Fire-resistance tests -- Elements of building construction -- Part 4: Specific requirements for loadbearing vertical separating elements

ICS
13.220.50
CCS
发布
2015-09-03
实施

This part of ISO 5658 specifies a method of test for measuring the lateral spread of flame along the surface of a specimen of a product orientated in the vertical position. It provides data suitable for comparing the performance of essentially flat materials, composites or assemblies that are used primarily as the exposed surfaces of walls in buildings and transport vehicles, such as ships and trains. Some profiled products (such as pipes) can also be tested under specified mounting and fixing conditions. This part of ISO 5658 is applicable to the measurement and description of the properties of materials, products or assemblies in response to radiative heat in the presence of a pilot flame under controlled laboratory conditions. It is not suitable to be used alone to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions.

Reaction to fire tests -- Spread of flame -- Part 2: Lateral spread on building and transport products in vertical configuration

ICS
13.220.50
CCS
发布
2015-09-03
实施

This part of ISO 834 specifies the procedures to be followed for determining the fire resistance of columns when tested on their own. Columns are normally tested with all sides fully exposed to heating. However, when in practice the exposure is from fewer than four sides, appropriate exposure conditions have to be reproduced. The application of this test to other untested forms of construction is acceptable when the construction complies with the direct field of application as given in this part of ISO 834 or when subjected to an extended application analysis in accordance with ISO/TR 12470. Since ISO/TR 12470 gives only general guidelines, specific extended application analyses are to be performed only by persons expert in fire-resistant constructions. General guidance on this test method is given in annex A.

Fire-resistance tests -- Elements of building construction -- Part 7: Specific requirements for columns

ICS
13.220.50
CCS
发布
2015-09-03
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号