13.230 防爆 标准查询与下载



共找到 376 条与 防爆 相关的标准,共 26

Determination of the limiting oxygen concentration (LOC) for flammable gases and vapours

ICS
13.230
CCS
发布
2007-05-15
实施
2007-05-15

This European Standard specifies the requirements for venting devices used to protect enclosures against the major effects of internal explosions arising from the rapid burning of suspended dust, vapour or gas contained within. It includes the requirements for the design, inspection, testing, marking, documentation and packaging. This European Standard specifies explosion venting devices which are put on the market as autonomous protective systems.Explosion venting devices are safety devices comprised of a pressure sensitive membrane fixed to and forming part of the structure that it protects, designed to intervene in the event of an explosion at a predeter

Explosion venting devices

ICS
13.230
CCS
发布
2007-04-26
实施
2007-04-26

Gas explosion venting protective systems.

ICS
13.230
CCS
C66
发布
2007-04-01
实施
2007-04-20

This European Standard specifies the requirements for venting devices used to protect enclosures against the major effects of internal explosions arising from the rapid burning of suspended dust, vapour or gas contained within. It includes the requirements for the design, inspection, testing, marking, documentation and packaging. This European Standard specifies explosion venting devices which are put on the market as autonomous protective systems. Explosion venting devices are safety devices comprised of a pressure sensitive membrane fixed to and forming part of the structure that it protects, designed to intervene in the event of an explosion at a predetermined low pressure, to immediately open a vent area sufficient to ensure that the maximum pressure attained by the explosion within the enclosure does not exceed its designed resistance to pressure. The application and specification of explosion venting devices is outlined for dust explosion protection in EN 14491 and for gas explosion protection in prEN 14994. The use of venting devices according to this European Standard on pipelines and on applications other than described in EN 14491 or prEN 14994 needs to be carefully evaluated and where appropriate their suitability needs to be confirmed by tests. Flameless explosion venting devices avoid the breakthrough of flames into the surroundings. They are used to allow explosion venting in situations where the hazards of flames resulting from the venting action are not acceptable. Flameless explosion venting devices are treated in a separate standard. This European Standard does not cover details for the avoidance of ignition sources from detection devices or other parts of the venting devices.

Explosion venting devices; English version of DIN EN 14797:2007-03

ICS
13.230
CCS
C67
发布
2007-03
实施

This European Standard specifies the requirements for venting devices used to protect enclosures against the major effects of internal explosions arising from the rapid burning of suspended dust, vapour or gas contained within. It includes the requirements for the design, inspection, testing, marking, documentation and packaging. This European Standard specifies explosion venting devices which are put on the market as autonomous protective systems. Explosion venting devices are safety devices comprised of a pressure sensitive membrane fixed to and forming part of the structure that it protects, designed to intervene in the event of an explosion at a predetermined low pressure, to immediately open a vent area sufficient to ensure that the maximum pressure attained by the explosion within the enclosure does not exceed its designed resistance to pressure. The application and specification of explosion venting devices is outlined for dust explosion protection in EN 14491 and for gas explosion protection in prEN 14994. The use of venting devices according to this European Standard on pipelines and on applications other than described in EN 14491 or prEN 14994 needs to be carefully evaluated and where appropriate their suitability needs to be confirmed by tests. Flameless explosion venting devices avoid the breakthrough of flames into the surroundings. They are used to allow explosion venting in situations where the hazards of flames resulting from the venting action are not acceptable. Flameless explosion venting devices are treated in a separate standard. This European Standard does not cover details for the avoidance of ignition sources from detection devices or other parts of the venting devices.

Explosion venting devices

ICS
13.230
CCS
C67
发布
2007-02-28
实施
2007-02-28

This standard specifies requirements for explosion-pressure-resistant and explosion pressure shock-resistant equipment. This standard is applicable to process vessels and systems. It is not applicable to individual items of equipment such as motors and gearboxes that may be designed to withstand an internal explosion, which is the subject of EN 13463-3. This standard is valid for atmospheres having pressures ranging from 800 hPa to 1100 hPa and temperatures ranging from - 20 °C to + 60 °C. This standard may also be helpful for the design, construction, testing and marking of equipment intended for use in atmospheres outside the validity range stated above, as far as this subject is not covered by specific standards. This standard applies to equipment and combinations of equipment where deflagrations may occur and is not applicable to equipment and combination of equipment where detonation may occur. This standard should not be used for offshore applications. It is essential that this standard be used for equipment made of metallic materials only.

Explosion resistant equipment

ICS
13.230
CCS
C67
发布
2007-02-28
实施
2007-02-28

Explosion venting devices

ICS
13.230
CCS
发布
2007-02-28
实施
2007-02-28

Explosion resistant equipment

ICS
13.230
CCS
发布
2007-02-28
实施
2007-02-28

This European Standard specifies the method for determining the LOC of mixtures consisting of flammablegas or vapour, air and inert gas at atmospheric pressure and temperatures from ambient temperature to200 °C.

Determination of the limiting oxygen concentration (LOC) for flammable gases and vapours

ICS
13.230
CCS
发布
2007-02-26
实施
2007-02-26

This European Standard specifies the method for determining the LOG of mixtures consisting of flammable gas or vapour, air and inert gas at atmospheric pressure and temperatures from ambient temperature to 200 °C.

Determination of the limiting oxygen concentration (LOC) for flammable gases and vapours; English version of DIN EN 14756:2007-02

ICS
13.230
CCS
C67
发布
2007-02
实施

This European Standard specifies the method for determining the LOC of mixtures consisting of flammable gas or vapour, air and inert gas at atmospheric pressure and temperatures from ambient temperature to 200 °C.

Determination of the limiting oxygen concentration (LOC) for flammable gases and vapours

ICS
13.230
CCS
C67
发布
2007-01-31
实施
2007-01-31

Determination of the limiting oxygen concentration (LOC) for flammable gases and vapours

ICS
13.230
CCS
发布
2007-01-31
实施
2007-01-31

Determination of the limiting oxygen concentration (LOC) for flammable gases and vapours.

ICS
13.230
CCS
C67
发布
2007-01-01
实施
2007-01-05

This Clause of EN 50194 is replaced by:This European Standard specifies test methods and performance requirements for electricalapparatus for the detection of combustible gases designed for continuous operation in a fixedinstallation in recreational vehicles and similar premises.NOTE 1 For caravan holiday homes EN 50194 applies.This standard specifies apparatus designed to operate in the event of an escape of liquefiedpetroleum gas (LPG) and/or petrol (gasoline) vapour and to provide a visual and audible alarmand an executive action in the form of an output signal that can actuate directly or indirectly ashut-off device and/or other ancillary device (Type A

Electrical apparatus for the detection of combustible gases in domestic premises - Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises - Additional test methods and performance requir

ICS
13.230
CCS
发布
2006-11-28
实施
2006-11-28

Explosion resistant equipment

ICS
13.230
CCS
发布
2006-08-31
实施
2006-08-31

This standard specifies requirements for explosion-pressure-resistant and explosion pressure shock-resistant equipment. This standard is applicable to process vessels and systems. It is not applicable to individual items of equipment such as motors and gearboxes that may be designed to withstand an internal explosion, which is the subject of EN 13463-3.This standard is valid for atmospheres having pressures ranging from 800 hPa to 1100 hPa and temperatures ranging from - 20 °C to + 60 °C. This standard may also be helpful for the design, construction, testing and marking of equipment intended for use in atmospheres outside the validity range stated above, a

Explosion resistant equipment

ICS
13.230
CCS
发布
2006-08-30
实施
2006-08-30

Inerting is a measure to prevent explosions. By feeding inert gas into a system which is to be protected against an explosion, the oxygen content is reduced below a certain concentration until no explosion can occur. The addition of sufficient inert gas to make any mixture non-flammable when mixed with air (absolute inerting) is only required in rare occasions. The requirements for absolute inerting will be discussed. Inerting may also be used to influence the ignition and explosion characteristics of an explosive atmosphere.The guidance given on inerting is also applicable to prevent an explosion in case of a fire.The following cases are not covered by the

Guidance on Inerting for the Prevention of Explosions

ICS
13.230
CCS
发布
2006-08-30
实施
2006-08-30

Determination of explosion characteristics of dust clouds - Part 3 : determination of the lower explosion limit LEL of dust clouds.

ICS
13.230
CCS
C67
发布
2006-07-01
实施
2006-07-20

Determination of explosion characteristics of dust clouds - Part 2 : determination of the minimum rate of explosion pressure rise (dp/dt)max of dust clouds.

ICS
13.230
CCS
C67
发布
2006-07-01
实施
2006-07-20

This standard describes a test method for the determination of the lower explosion limit of dust clouds in a closed vessel under defined initial conditions of pressure and temperature. This method is not suitable for use with recognised explosives, like gunpowder and dynamite, explosives which do not require oxygen for combustion, pyrophoric substances, or substances or mixtures of substances which may under some circumstances behave in a similar manner. Where any doubt exists about the existence of hazard due to explosive properties, expert advice should be sought.

Determination of explosion characteristics of dust clouds - Determination of the lower explosion limit LEL of dust clouds

ICS
13.230
CCS
C67
发布
2006-06-30
实施
2006-06-30



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved