17.120.20 明渠中流量的测量 标准查询与下载



共找到 565 条与 明渠中流量的测量 相关的标准,共 38

This International Standard specifies the functional requirements of the equipment, excluding bankside cableway systems, used in the measurement of liquid flow in open channels for a) sounding (by direct method), and b) suspending the measuring equipment (for example, current-meter or sediment sampler) at the point of measurement.

Hydrometry - Direct depth sounding and suspension equipment

ICS
17.120.20
CCS
N12
发布
2008-05-30
实施
2008-05-30

This International Standard defines the requirements for the use of rectangular and triangular (V-notch) thinplate weirs for the measurement of flow of clear water in open channels under free flow conditions. It includes the requirements for the use of full-width rectangular thin-plate weirs in submerged (drowned) flow conditions.

Hydrometry - Open channel flow measurement using thin-plate weirs

ICS
17.120.20
CCS
N12
发布
2008-05-30
实施
2008-05-30

Liquid flow measurement in open channels. Rectangular, trapezoidal and U-shaped flumes

ICS
17.120.20
CCS
发布
2008-05-30
实施
2008-05-30

This International Standard specifies the functional requirements of the equipment, excluding bankside cableway systems, used in the measurement of liquid flow in open channels for a) sounding (by direct method), and b) suspending the measuring equipment (for example, current-meter or sediment sampler) at the point of measurement.

Hydrometry - Direct depth sounding and suspension equipment

ICS
17.120.20
CCS
N12
发布
2008-04-15
实施

This International Standard lays down requirements for the use of rectangular broad-crested weirs for the accurate measurement of flow of clear water in open channels under free flow conditions.

Hydrometry - Open channel flow measurement using rectangular broad-crested weirs

ICS
17.120.20
CCS
N12
发布
2008-03-31
实施
2008-03-31

ISO 4360:2008 specifies methods for the measurement of the flow of water in open channels under steady flow conditions using triangular profile weirs. The flow conditions considered are steady flows which are uniquely dependent on the upstream head and drowned flows which depend on downstream as well as upstream levels.

Hydrometry - Open channel flow measurement using triangular profile weirs

ICS
17.120.20
CCS
A53
发布
2008-03-31
实施
2008-03-31

ISO 4360:2008 specifies methods for the measurement of the flow of water in open channels under steady flow conditions using triangular profile weirs. The flow conditions considered are steady flows which are uniquely dependent on the upstream head and drowned flows which depend on downstream as well as upstream levels.

Hydrometry - Open channel flow measurement using triangular profile weirs

ICS
17.120.20
CCS
P12
发布
2008-03-01
实施

This International Standard lays down requirements for the use of rectangular broad-crested weirs for the accurate measurement of flow of clear water in open channels under free flow conditions.

Hydrometry - Open channel flow measurement using rectangular broad-crested weirs

ICS
17.120.20
CCS
A50
发布
2008-02-15
实施

This International Standard specifies methods for determining the velocity and cross-sectional area of water flowing in open channels without ice cover, and for computing the discharge therefrom. It covers methods of employing current-meters or floats to measure the velocities. It should be noted that although, in some cases, these measurements are intended to determine the stage-discharge relation of a gauging station, this International Standard deals only with single measurements of the discharge; the continuous recording of discharges over a period of time is covered in ISO 1100-1 and ISO 1100-2. NOTE The methods for determining the velocity and cross-sectional area of water flowing in open channels with ice cover are specified in ISO 9196.

Hydrometry - Measurement of liquid flow in open channels using current-meters or floats (ISO 748:2007); English version of DIN EN ISO 748:2008-02

ICS
17.120.20
CCS
A42
发布
2008-02
实施

Hydrometry - Measurement of liquid flow in open channels using current-meters or floats (ISO 748:2007)

ICS
17.120.20
CCS
发布
2008-01-30
实施
2008-01-30

This International Standard specifies methods for determining the velocity and cross-sectional area of water flowing in open channels without ice cover, and for computing the discharge therefrom.It covers methods of employing current-meters or floats to measure the velocities. It should be noted that although, in some cases, these measurements are intended to determine the stage-discharge relation of a gauging station, this International Standard deals only with single measurements of the discharge; the continuous recording of discharges over a period of time is covered in ISO 1100-1 and ISO 1100-2.NOTE The methods for determining the velocity and cross-sec

Hydrometry - Measurement of liquid flow in open channels using current-meters or floats

ICS
17.120.20
CCS
发布
2008-01-25
实施
2008-01-25

This document proposes a framework for the drafting of technical Standards in the field of hydrometry. It follows the rules set out in ISO 'Guide to the expression of uncertainty in measurement' (GUM) and will assist users in applying the GUM.

Hydrometric uncertainty guidance (HUG)

ICS
17.120.20
CCS
发布
2008-01-18
实施
2008-01-18

This International Standard specifies the functional requirements of instrumentation for measuring the level ofwater surface (stage), primarily for the purpose of determining flow rates.This International Standard issupplemented by an annex providing guidance on the types of water level measurement devices currentlyavailable and the measurement uncertainty associated with them (see Annex A).

Hydrometry - Water level measuring devices (ISO 4373:2008)

ICS
17.120.20
CCS
发布
2008
实施

This International Standard specifies methods for determining the velocity and cross-sectional area of water flowing in open channels without ice cover, and for computing the discharge therefrom. It covers methods of employing current-meters or floats to measure the velocities. It should be noted that although, in some cases, these measurements are intended to determine the stage-discharge relation of a gauging station, this International Standard deals only with single measurements of the discharge; the continuous recording of discharges over a period of time is covered in ISO 1100-1 and ISO 1100-2. NOTE The methods for determining the velocity and cross-sectional area of water flowing in open channels with ice cover are specified in ISO 9196.

Hydrometry - Measurement of liquid flow in open channels using current-meters or floats

ICS
17.120.20
CCS
A42
发布
2007-11-30
实施
2007-11-30

This Technical Specification provides an understanding of the nature of measurement uncertainty and its significance in estimating the ‘quality’ of a measurement or a determination in hydrometry. It is applicable to flow measurements in natural and man-made channels. Rainfall measurements are not covered.

Hydrometric uncertainty guide

ICS
17.120.20
CCS
A42
发布
2007-11-30
实施
2007-11-30

Respiratory protective devices - Human factors - Part 1: Metabolic rates and respiratory flow rates

ICS
17.120.20
CCS
C69
发布
2007-10-01
实施

This Technical Specification provides an understanding of the nature of measurement uncertainty and its significance in estimating the ‘quality’ of a measurement or a determination in hydrometry. It is applicable to flow measurements in natural and man-made channels. Rainfall measurements are not covered.

Hydrometric uncertainty guidance (HUG)

ICS
17.120.20
CCS
A42
发布
2007-10-01
实施

This International Standard specifies methods for determining the velocity and cross-sectional area of water flowing in open channels without ice cover, and for computing the discharge therefrom. It covers methods of employing current-meters or floats to measure the velocities. It should be noted that although, in some cases, these measurements are intended to determine the stage-discharge relation of a gauging station, this International Standard deals only with single measurements of the discharge; the continuous recording of discharges over a period of time is covered in ISO 1100-1 and ISO 1100-2. NOTE The methods for determining the velocity and cross-sectional area of water flowing in open channels with ice cover are specified in ISO 9196.

Hydrometry - Measurement of liquid flow in open channels using current-meters or floats

ICS
17.120.20
CCS
A50
发布
2007-10
实施

This International Standard provides a standard basis for the collection and processing of data for the determination of the uncertainties in measurements of discharge in open channels by velocity-area methods using current-meters. To determine the discharge in open channels by the velocity-area method, components of the flow (velocity, depth and breadth) need to be measured. The component measurements are combined to compute the total discharge. The total uncertainty in the computed discharge is a combination of the uncertainties in the measured components. Clause 4 of this International Standard deals with the types of errors and uncertainties involved. Clauses 5 and 6 present a standard procedure to estimate the component uncertainties by the collection and processing of the necessary data. This International Standard is intended to be applied to velocity-area methods that involve measurement of point velocities at a relatively small number of discrete depths and transverse positions in the flow crosssection, as described in ISO 748. This International Standard is not intended to be applied to measurements made by Acoustic Doppler Velocity Profilers (ADVP) or other instruments that produce essentially continuous velocity profiles of the flow field.

Hydrometry. Velocity-area methods using current-meters. Collection and processing of data for determination of uncertainties in flow measurement

ICS
17.120.20
CCS
A53
发布
2007-07-31
实施
2007-07-31

This International Standard provides a standard basis for the collection and processing of data for the determination of the uncertainties in measurements of discharge in open channels by velocity-area methods using current-meters. To determine the discharge in open channels by the velocity-area method, components of the flow (velocity, depth and breadth) need to be measured. The component measurements are combined to compute the total discharge. The total uncertainty in the computed discharge is a combination of the uncertainties in the measured components. Clause 4 of this International Standard deals with the types of errors and uncertainties involved. Clauses 5 and 6 present a standard procedure to estimate the component uncertainties by the collection and processing of the necessary data. This International Standard is intended to be applied to velocity-area methods that involve measurement of point velocities at a relatively small number of discrete depths and transverse positions in the flow crosssection, as described in ISO 748. This International Standard is not intended to be applied to measurements made by Acoustic Doppler Velocity Profilers (ADVP) or other instruments that produce essentially continuous velocity profiles of the flow field.

Hydrometry - Velocity-area methods using current-meters - Collection and processing of data for determination of uncertainties in flow measurement

ICS
17.120.20
CCS
A53
发布
2007-07
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号