19.080 电工和电子试验 标准查询与下载



共找到 484 条与 电工和电子试验 相关的标准,共 33

This part of IEC 61557 specifies the requirements applicable to equipment for measuring the resistance of earth conductors, protective earth conductors and conductors for equipotential bonding, including their connections and terminals, with an indication of the measured value or indication of limits.

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures -- Part 4: Resistance of earth connection and equipotential bonding

ICS
19.080
CCS
发布
2007-08-28
实施
2007-08-28

This part of IEC 61557 specifies the requirements for equipment for measuring earth resistance using an a.c. voltage.

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth

ICS
19.080
CCS
发布
2007-07-30
实施
2007-07-30

This part of IEC 61557 specifies the requirements for measuring equipment applied to testing the phase sequence in three-phase distribution systems. Indication of the phase sequence may be mechanical, visual and/or audible.This part of IEC 61557 does not apply to ancillary measuring equipment for other quantities, for example voltage testers comprising an additional phase sequence indicator. It does not apply to monitoring relays.NOTE Phase lamps are not considered to be voltage testers.

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence

ICS
19.080
CCS
发布
2007-07-30
实施
2007-07-30

Applies to hand-held and hand-manipulated CURRENT CLAMPS. These CURRENT CLAMPS are for use in the measurement of current without interruption of the current path of the circuit in which it is measured. They may be stand-alone CURRENT CLAMPS which are themselves within the scope of part 1, or accessories to other equipment within the scope of part 1. This standard does not apply to current transformers or current transducers intended for fixed installations. This standard has the status of a group safety publication.

Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement

ICS
19.080
CCS
发布
2007-06-05
实施

This commercial item description (CID) covers low tension cables used for connections between storage batteries and other electrical equipment. The insulated leads are used for connections between the battery and equipment where heavy amperage 6-, 12-, and 24-volt (V) ungrounded circuits interconnect. The uninsulated leads and straps are used for bonding and grounding connections.

LEADS, STORAGE-BATTERY

ICS
19.080
CCS
A25
发布
2007-05-01
实施

Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test (First Edition)

ICS
19.080
CCS
发布
2007-03-30
实施

Cette norme relative aux appareils électriques de mesurage, de régulation et de laboratoire est commune à la CSA, à l'ISA et aux UL. 1 Domaine d'application et objet 1.1 Domaine d'application La présente partie de la CEI 61010 s'applique aux SONDES ÉQUIPÉES tenues à la main et manipulées, correspondant aux types décrits ci-dessous, ainsi qu'à leurs accessoires destinés aux usages professionnels, industriels (processus) et éducatifs. Ces SONDES ÉQUIPÉES, sont destinées à être utilisées dans l'interface entre un phénomène électrique et un instrument de mesure ou d'essai. Elles peuvent être liées à l'appareil ou en être des accessoires détachables. a) SONDES ÉQUIPÉES, sans atténuation, à basse tension et à haute tension (type A). SONDES ÉQUIPÉES, sans atténuation ASSIGNÉES pour connexion directe à des tensions supérieures à 33 V efficaces ou à 46,7 V crête ou à 70 V continu mais ne dépassant pas 63 kV. Elles ne comportent aucun composant actif, et ne sont pas non plus conçues pour assurer la fonction de diviseur capacitif ou de mise en forme de signaux, mais elles peuvent contenir des composants passifs ne provoquant pas d'atténuation tels que des fusibles. b) SONDES ÉQUIPÉES à atténuateur ou diviseur à haute tension (type B). SONDES ÉQUIPÉES à atténuateur ou diviseur ASSIGNÉES pour connexion directe sur des tensions secondairessupérieures à 1 kV mais n'excédant pas 63 kV. La fonction diviseur peut être réalisée dans sa totalité à l'intérieur de la SONDE ÉQUIPÉE, ou en partie dans l'appareil de mesurage ou d'essai destiné à être utilisé avec la SONDE ÉQUIPÉE. c) SONDES ÉQUIPÉES à atténuateur ou diviseur à basse tension (type C). SONDES ÉQUIPÉES à atténuateur, à diviseur ou autre conditionneur de signal pour connexion directe à des tensions supérieures à 33 V efficaces ou à 46,7 V crête ou à 70 V continu, mais ne dépassant pas 1 kV efficace ou 1,5 kV continu. La fonction conditionneur de signal peut être réalisée dans sa totalité à l'intérieur de la SONDE ÉQUIPÉE, ou en partie à l'intérieur de l'appareil de mesurage ou d'essai destiné à être utilisé avec la SONDE ÉQUIPÉE. NOTE Les SONDES ÉQUIPÉES - qui ne correspondent pas aux définitions des types A, B ou C, ou, - qui sont conçues pour être alimentées à partir d'un réseau de distribution basse tension, ou, - qui incorporent d'autres fonctionnalités non particulièrement adressées dans cette présente norme peuvent avoir aussi besoin d'être conformes aux prescriptions pertinentes des autres parties de la CEI 61010 [6]1).

Safety rules for electrical measuring, regulating and laboratory apparatus - Part 031: Safety requirements for equipped hand-held probes for electrical measurement and testing

ICS
19.080
CCS
发布
2007-03-01
实施

1 Scope and object 1.1 Scope This part of IEC 61010 applies to hand-held and hand-manipulated PROBE ASSEMBLIES of the types described below, and related accessories which are intended for professional, industrial process, and educational use. These PROBE ASSEMBLIES are for use in the interface between an electrical phenomenon and test or measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. a) Low-voltage and high-voltage, non-attenuating PROBE ASSEMBLIES (type A). Non-attenuating PROBE ASSEMBLIES that are RATED for direct connection to voltages exceeding 33 V r.m.s. or 46,7 V peak or 70 V d.c., but not exceeding 63 kV. They do not incorporate active components, nor are they intended to provide a voltage divider function or a signal conditioning function, but they may contain passive non-attenuating components such as fuses. b) High-voltage attenuating or divider PROBE ASSEMBLIES (type B). Attenuating or divider PROBE ASSEMBLIES that are RATED for direct connection to secondary voltages exceeding 1 kV but not exceeding 63 kV. The divider function may be carried out wholly within the PROBE ASSEMBLY, or partly within the test or measurement equipment to be used with the PROBE ASSEMBLY. c) Low-voltage attenuating or divider PROBE ASSEMBLIES (type C). Attenuating, divider or other signal conditioning PROBE ASSEMBLIES for direct connection to voltages exceeding 33 V r.m.s or 46,7 V peak or 70 V d.c., but not exceeding 1 kV r.m.s. or 1,5 kV d.c. The signal conditioning function may be carried out wholly within the PROBE ASSEMBLY, or partly within the test or measurement equipment intended to be used with the PROBE ASSEMBLY. NOTE PROBE ASSEMBLIES which - are not within the definitions of types A, B or C, or, - which are designed to be powered from a low-voltage mains supply, or - include other features not specifically addressed in this standard may also need to meet the relevant requirements of other parts of IEC 61010 [6]1).

Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test

ICS
19.080
CCS
发布
2007-03-01
实施

The activities above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http://assist.daps.dla.mil.

BATTERIES, NON-RECHARGEABLE, HIGH PERFORMANCE

ICS
19.080
CCS
A25
发布
2007-02-22
实施

This parf of 60060 is applicable to the following on-site test voltages and in service stresses, which are in relation to 60060-1:- direcet voltage;- lightning impulse voltage of aperiodic or oscillating shape;- switching impulse voltage of aperiodic or oscillating shape.For special tests the following voltages are used: - very low frequency voltage;- damped alternating voltage.

High voltage test techniques - Part 3: Definitions and requirements for on-site tests

ICS
19.080
CCS
发布
2006-12-21
实施
2006-12-21

この規格は,次の手持形及び手で操作する電流センサについて規定する。これらの電流センサは,測定する回路の電路を切断することなく,電流を測定するときに用いるものである。

Safety requirements for electrical equipment for measurement, control, and laboratory use -- Part 2-32: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement

ICS
19.080
CCS
N20
发布
2006-11-20
实施

この規格は,専門家用,産業プロセス用及び教育用途で.次に示すタイプの手持形及び手で操作するプローブアセンブり,並びに関連附属品について規定する。これらのプローブアセンブリは,電気的現象と試験又は測定機器とのインタフュースに用いるものとする。これらは.機器に固定するか,又は機器に対して着脱可能な附属品であってもよい。

Safety requirements for electrical equipment for measurement, control, and laboratory use -- Part 31: Safety requirements for hand-held probe assemblies for electrical measurement and test

ICS
19.080
CCS
N20
发布
2006-11-20
实施

Identifies the requirements for on-site test voltages and in-service testing of high-voltage equipment with a highest voltage Um greater than 1 kV. Tests are applicable to direct voltage; alternating voltage; lightning impulse voltage of aperiodic or osc

High-voltage test techniques Part 3: Definitions and requirements for on-site testing

ICS
19.080
CCS
K04
发布
2006-08-25
实施

A-A-59352, dated 12 October 2000, has been reviewed and determined to be valid for use in acquisition.

BATTERY, DRY, BA-223/U

ICS
19.080
CCS
A25
发布
2006-08-21
实施

High voltage test techniques - Part 3: Definitions and requirements for on-site tests (IEC 60060-3:2006); German version EN 60060-3:2006

ICS
19.080
CCS
A42
发布
2006-08
实施
2006-08-01

This commercial item description (CID) covers a +22.5/45 VDC dry-cell battery. The battery is intended for use in test equipment, radio sets, and other portable electronic and communication equipment powered by non-rechargeable dry cell batteries.

BATTERY, DRY, BA-53

ICS
19.080
CCS
A25
发布
2006-06-21
实施

This commercial item description (CID) covers a +22.5 VDC dry-cell battery. The battery is intended for use in test equipment, radio sets, and other portable electronic and communication equipment powered by non-rechargeable dry cell batteries.

BATTERY, DRY, BA-2

ICS
19.080
CCS
A25
发布
2006-06-21
实施

The General Services Administration has authorized the use of this commercial item description for all federal agencies.

BATTERY, DRY, BA-59

ICS
19.080
CCS
A25
发布
2006-06-21
实施

Accelerated life test-Part 3:Data analysis of accelerated life test

ICS
19.080
CCS
发布
2006-06-02
实施

이 규격에서는 가속 수명 시험의 설계와 데이터 분석을 위해 필요한 기본 개념을 제시한다.

Accelerated life test-Part 1:Outline of accelerated life test

ICS
19.080
CCS
A69
发布
2006-06-02
实施
2006-06-02



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved