23.020.10 固定容器和罐 标准查询与下载



共找到 599 条与 固定容器和罐 相关的标准,共 40

Leak detection systems - Part 5: Tank gauge leak detection systems

ICS
23.020.10
CCS
发布
2007-04-16
实施
2007-04-16

These requirements cover nonmetallic safety cans that have nominal capacities of 5 Imperial gallons or less and that are primarily intended to store and handle fuel oil, gasoline, kerosene. Nonmetallic safety cans that are intended to store and handle liquid fuels other than those specified above may be subjected to additional requirements not covered in the Standard. These requirements cover cans of two types, designated herein as Type I and Type II.

UL Standard for Safety Nonmetallic Safety Cans for Petroleum Products STP BALLOTS AND ALL COMMENTS DUE: MAY 21, 2007

ICS
23.020.10
CCS
G93
发布
2007-04-06
实施

Standard Practice for Emergency Joining of Booms with Incompatible Connectors

ICS
23.020.10
CCS
发布
2007-04-01
实施

The standard describes a procedure for the proof of conformity of workshop fabricated steel tanks manufactured according to certain product standards by means of a certificate of conformity.

Steel tanks for the storage of water-polluting liquids - Declaration of conformity

ICS
23.020.10
CCS
A82
发布
2007-04
实施

The list of liquids shows the chemical name of those liquids which are intended to store in metallic tanks. Moreover the list contains instructions which have to be met by storage of these liquids.

Resistance of materials of steel tanks against liquids (positiv-list of liquids)

ICS
23.020.10
CCS
A82
发布
2007-04
实施

This European Standard specifies the requirements for materials, design and installation of the insulation of refrigerated liquefied gas (RLG) storage tanks.RLG storage tanks store liquefied gas with a low boiling point, i.e. below normal ambient temperature.The concept of storing such products in liquid form and in non-pressurized tanks therefore depends on the combination of latent heat of vaporization and thermal insulation.Consequently thermal insulation for RLG storage tanks is not an ancillary part of the containment system (as for most ambient atmospheric hydrocarbon tanks) but it is an essential component and the storage tank cannot operate without

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Part 4: Insulation components

ICS
23.020.10
CCS
发布
2007-03-28
实施
2007-03-28

This European Standard specifies the requirements for testing, drying, purging and cool-down of the refrigerated liquefied gas storage tanks.This European Standards deals with the design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C.

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Part 5: Testing, drying, purging and cool-down

ICS
23.020.10
CCS
发布
2007-03-28
实施
2007-03-28

This European Standard specifies general requirements for materials, design and construction of the concrete components of the refrigerated liquefied gas storage tanks.This European Standard deals with the design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C.

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Part 3: Concrete components

ICS
23.020.10
CCS
发布
2007-03-28
实施
2007-03-28

This European Standard specifies general requirements for the materials, design, construction andinstallation of the metallic components of refrigerated liquefied gas storage tanks.This European Standard deals with the design and manufacture of site built, vertical, cylindrical, flatbottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperaturesbetween 0 °C and –165 °C.

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Part 2: Metallic components

ICS
23.020.10
CCS
发布
2007-03-28
实施
2007-03-28

This European Standard is a specification for vertical, cylindrical tanks, built on site, above groundand of which the primary liquid container is made of steel. The secondary container, if applicable, maybe of steel or of concrete or a combination of both. An inner tank made only of pre-stressed concreteis excluded from the scope of this European Standard.This European Standard specifies principles and application rules for the structural design of the“containment” during construction, testing, commissioning, operation (accidental included), anddecommissioning. It does not address the requirements for ancillary equipment such as pumps,pumpwells, valves, pi

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Part 1: General

ICS
23.020.10
CCS
发布
2007-03-28
实施
2007-03-28

Safety specification for steel storage oil tank body underground of filling station

ICS
23.020.10
CCS
J74
发布
2007-02-14
实施
2007-03-15

These requirements cover preengineered corrosion protection systems. Part i covers factory-installed galvanic-type cathodic protection. Part ii covers factory assembled composite systems. Part iii covers factory assembled jacket systems. Part iv covers factory assembled coated systems. These corrosion protection systems are intended to be completely installed at the factory on carbon steel underground storage tanks. Part ii of this standard covers fiberglass reinforced plastic (FRP), materials only. Part iii of this standard covers FRP, polyurethane, polyurea and high density polyethylene (HDPE) materials only. Part iv covers polyurethane materials only. These corrosion protection systems are intended to be installed, operated and maintained in accordance with the manufacturer's instructions.

UL Standard for Safety External Corrosion Protection Systems for Steel Underground Storage Tanks Third Edition

ICS
23.020.10
CCS
A82
发布
2007-01-17
实施

이 규격은 강제의 전체 용접 직립 원통형 저장 탱크로서 고정 지붕이나 부상 지붕 또는 고정

Welded steel tanks for oil storage

ICS
23.020.10
CCS
J74
发布
2006-12-31
实施
2006-12-31

이 규격은 액체저장탱크에 작용하는 풍압하중의 설계, 지진하중의 설계 및 앵커의 설계요건에

Design requirements for wind load and seismic load of oil storage tanks

ICS
23.020.10
CCS
J74
发布
2006-12-31
实施
2006-12-31

This European Standard is a specification for vertical, cylindrical tanks, built on site, above ground and of which the primary liquid container is made of steel. The secondary container, if applicable, may be of steel or of concrete or a combination of both. An inner tank made only of pre-stressed concrete is excluded from the scope of this European Standard. This European Standard specifies principles and application rules for the structural design of the “containment” during construction, testing, commissioning, operation (accidental included), and decommissioning. It does not address the requirements for ancillary equipment such as pumps, pumpwells, valves, piping, instrumentation, staircases etc. unless they can affect the structural design of the tank. This European Standard applies to storage tanks designed to store products, having an atmospheric boiling point below ambient temperature, in a dual phase, i.e. liquid and vapour. The equilibrium between liquid and vapour phases being maintained by cooling down the product to a temperature equal to, or just below, its atmospheric boiling point in combination with a slight overpressure in the storage tank. The maximum design pressure of the tanks covered by this European Standard is limited to 500 mbar. For higher pressures, reference can be made to EN 13445, Parts 1 to 5. The operating range of the gasses to be stored is between 0 °C and –165 °C. The tanks for the storage of liquefied oxygen, nitrogen and argon are excluded. The tanks are used to store large volumes of hydrocarbon products and ammonia with low temperature boiling points, generally called “Refrigerated Liquefied Gases” (RLG’s). Typical products stored in the tanks are: methane, ethane, propane, butane, ethylene, propylene, butadiene (this range includes the LNG’s and LPG’s). NOTE Properties of the gases are given in Annex A. The requirements of this European Standard cannot cover all details of design and construction because of the variety of sizes and configurations that may be employed. Where complete requirements for a specific design are not provided, the intention is for the designer, subject to approval of the purchaser's authorized representative, to provide design and details that are as safe as those laid out in this European Standard. This European Standard specifies general requirements for the tank concept, selection and general design considerations.

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - General

ICS
23.020.10
CCS
J74
发布
2006-12-29
实施
2006-12-29

This European Standard specifies the requirements for testing, drying, purging and cool-down of the refrigerated liquefied gas storage tanks. This European Standards deals with the design and manufacture of site built, vertical, cylindrical, flatbottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and –165 °C.

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Testing, drying, purging and cool-down

ICS
23.020.10
CCS
J74
发布
2006-12-29
实施
2006-12-29

This European Standard specifies the requirements for materials, design and installation of the insulation of refrigerated liquefied gas (RLG) storage tanks. RLG storage tanks store liquefied gas with a low boiling point, i.e. below normal ambient temperature. The concept of storing such products in liquid form and in non-pressurized tanks therefore depends on the combination of latent heat of vaporization and thermal insulation. Consequently thermal insulation for RLG storage tanks is not an ancillary part of the containment system (as for most ambient atmospheric hydrocarbon tanks) but it is an essential component and the storage tank cannot operate without a properly designed, installed and maintained insulation system. The main functions of the insulation in RLG storage tanks are:  to maintain the boil off below the specific limits;  to protect the non low temperature parts/materials of the tank (mainly the outer tank) by maintaining these parts at their required ambient temperature;  to limit the cool-down of the foundations/soil underneath the tank to prevent damage by frost heave;  to prevent/minimize condensation and icing on the outer surfaces of the tank. A wide range of insulation materials is available. However the material properties differ greatly amongst the various generically different materials and also within the same generic group of materials. Therefore within the scope of this European Standard, only general guidance on selection of materials is given. NOTE For general guidance on selection of materials see Annex A. This European Standard deals with the design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and – 165 °C.

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Insulation components

ICS
23.020.10
CCS
J74
发布
2006-12-29
实施
2006-12-29

This European Standard specifies general requirements for materials, design and construction of the concrete components of the refrigerated liquefied gas storage tanks. This European Standard deals with the design and manufacture of site built, vertical, cylindrical, flatbottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and –165 °C.

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Concrete components

ICS
23.020.10
CCS
J74
发布
2006-12-29
实施
2006-12-29

This European Standard specifies general requirements for the materials, design, construction and installation of the metallic components of refrigerated liquefied gas storage tanks. This European Standard deals with the design and manufacture of site built, vertical, cylindrical, flatbottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and –165 °C.

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Metallic components

ICS
23.020.10
CCS
J74
发布
2006-12-29
实施
2006-12-29

This practice provides design, construction, and installation criteria for inclined ladders to be installed within cargo tanks. Where ladders are attached to platforms, see Fig. 1 and Fig. 2 . Values stated in SI units are to be regarded as the standard. The values stated in parentheses are provided for information purposes only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Practice for Inclined Cargo Tank Ladders

ICS
23.020.10
CCS
U26
发布
2006-12-26
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号