23.020.10 固定容器和罐 标准查询与下载



共找到 599 条与 固定容器和罐 相关的标准,共 40

Specification for the design and manufacture of site built, vertical, cylindrical, flat-bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperature and above

ICS
23.020.10
CCS
发布
2005-02-04
实施
2005-02-04

1 This document specifies the requirements for the materials, design, fabrication, erection, testing and inspection of site built, vertical, cylindrical, flat bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperatures and above, and the technical agreements that need to be reached (see Annex A). This document does not apply to tanks where the product is refrigerated to maintain it as a liquid at atmospheric pressure (see prEN 14620). This document is concerned with the structural integrity of the basic tank structure and does not provide requirements for considering process design, operational issues, safety and firefighting facilities, in-service inspection, maintenance or repair. These aspects are covered in detail in other Codes of Practice (see Annex B). 2 This document applies to closed-top tanks, with and without internal floating covers (see Annex C) and open-top tanks, with and without floating roofs (see Annexes D and E). It does not apply to 'lift-type' gas holders. 3 This document applies to storage tanks with the following characteristics: a) design pressure less than 500 mbar and design internal negative pressure not lower than 20 mbar (see 5.1 for pressure limitations); b) design metal temperature not lower than -40 ℃ and not higher than +300 ℃ (see 5.2.2); c) maximum design liquid level not higher than the top of the cylindrical shell. 4 The limits of application of this document terminate at the following locations. — face of the first flange in a bolted flange connection; — first threaded joint on the pipe or coupling outside of the tank shell, roof or bottom; — first circumferential joint in a pipe not having a flange connection. 5 This document is applicable to steel tanks with a maximum design strength ≤ 260 N/mm. 6 In addition to the definitive requirements, this document also requires the items detailed in Annex A to be documented. For compliance with this document, both the definitive requirements and those required in Clause 4 have to be satisfied. note:1) All pressures are in mbar gauge unless otherwise stated.

Specification for the design and manufacture of site built,vertical,cylindrical,flat-bottomed,above ground,welded,steel tanks for the storage of liquids at ambient temperature and above

ICS
23.020.10
CCS
P34
发布
2005-02-04
实施
2005-02-04

This document specifies the requirements for metallic shop fabricated cylindrical, horizontal steel tanks, single and double skin forThe aboveground storage of water polluting liquids (both flammable and non-flammable) withinThe following limits:? from 800 mm up to 3 000 mm nominal diameter and, ? up to a maximum overall length of 6 timesThe nominal diameter and, ? for liquids with a maximum density of up to 1,9 kg/l and, ? with an operating pressure (Po) of maximum 1,5 bar (abs.) and, ? where double skin tanks with a vacuum leak detection system are usedThe cinematic viscosity of the stored media shall not exceed 5 × 10-3 m2/s.

Workshop fabricated steel tanks - Part 2: Horizontal cylindrical single skin and double skin tanks for the aboveground storage of flammable and non-flammable water polluting liquids

ICS
23.020.10
CCS
发布
2005-02-01
实施

This European Standard specifies the requirements for the materials, design, fabrication, erection, testing and inspection of site built, vertical, cylindrical, flat bottomed, above ground, welded, steel tanks with a maximum design stress of 260 N/mm2 for the storage of liquids at ambient temperatures and above, and the technical agreements that need to be reached. It applies to closed-top tanks, with and without internal floating covers, and open-top tanks, with and without floating roofs. It does not apply to 'lift-type' gas holders.

Specification for the design and manufacture of site built, vertical, cylindrical, flat-bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperature and above; German version EN 14015:2004

ICS
23.020.10
CCS
P71
发布
2005-02
实施

This European Standard specifies the requirements for the materials, design, fabrication, erection, testing and inspection of site built, vertical, cylindrical, flat bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperatures and above, and the technical agreements that need to be reached (see Annex A). This document does not apply to tanks where the product is refrigerated to maintain it as a liquid at atmospheric pressure (see prEN 14620). This document is concerned with the structural integrity of the basic tank structure and does not provide requirements for considering process design, operational issues, safety and fi

Specification for the design and manufacture of site built, vertical, cylindrical, flat-bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperature and above

ICS
23.020.10
CCS
发布
2005-01-27
实施
2005-01-27

This document gives requirements for delivery, installation and maintenance of GRP tanks and vessels in accordance with prEN 13121-3.

GRP tanks and vessels for use above ground - Delivery, installation and maintenance

ICS
23.020.10
CCS
A82
发布
2005-01-26
实施
2005-01-26

Leak detection systems - Part 5: Tank gauge leak detection systems

ICS
23.020.10
CCS
发布
2005-01-15
实施
2005-01-15

本标准适用于多管圆筒型热交换器之管板计算:其适用方法参照CNS 9788。

Flat tube sheet for pressure vessels

ICS
23.020.10
CCS
发布
2005-01-10
实施
2005-01-10

本标准适用于为吸收CNS 9788〔压力容器(通则)〕中第3节压力容器之等级分类中所规定之第二种及第三种压力容器之热交换器、附夹套容器等因温度变化等所产生在轴方向之伸缩而设置之伸缩接头之设计、制造及检查方法。其适用之方法系依CNS 9788第6.12节伸缩接头之规定。但对于第3

Expansion joint for pressure vessels

ICS
23.020.10
CCS
发布
2005-01-10
实施
2005-01-10

本标准适用于熔接方式装设于压力容器对侧之压力室(以下称夹套)之构造。其适用之方法,依CNS 9788〔压力容器(通则)〕之规定。.将压力容器及其内容物加热。.将压力容器及其内容物冷却。.于压力容器设密封隔热室。

Jacket for pressure vessels

ICS
23.020.10
CCS
发布
2005-01-10
实施
2005-01-10

本标准适用于受内压或外压之胴体与端板之计算。其适用之方法请参考CNS 9788〔压力容器(通则)〕之规定。备考1. 本标准中规定之设计法(1),系使用于CNS 9788第3节(压力容器之等级分类)中所定之第2种容器及第3种容器之计算;设计法(2)则使用于第1种容器之计算。2. 本标准所引

Shell and head of pressure vessels

ICS
23.020.10
CCS
发布
2005-01-10
实施
2005-01-10

本标准适用于压力容器以棒、管或板(以下称为牵条)支撑时,其平端板、管板等之强度计算。且相关工法亦应适用CNS 9788〔压力容器(通则)〕之规定。

Stayed plate for pressure vessels

ICS
23.020.10
CCS
发布
2005-01-10
实施
2005-01-10

This document gives requirements for delivery, installation and maintenance of GRP tanks and vessels in accordancewith prEN 13121-3.

GRP tanks and vessels for use above ground - Part 4: Delivery, installation and maintenance

ICS
23.020.10
CCS
发布
2005-01-01
实施

Leak detection systems - Part 5 : tank gauge leak detection systems.

ICS
23.020.10
CCS
J15
发布
2005-01-01
实施
2005-01-20

These requirements cover horizontal atmosheric-type steel tanks intended for the storage underground of flammable and combustible liquids. These tanks are intended for installation and use in accordance with the Standard for the Installation of Oil-Burning Equipment, NFPA 31, and the Flammable and Combustible Liquids Code, NFPA 30, of the National Fire Protection Association. Tanks covered by these requirements are cylindrical tanks which are fabricated, inspected, and tested for leakage before shipment from the factory as completely assembled vessels.

CSDS 6/30/2005 (24p)

ICS
23.020.10
CCS
发布
2005-01-01
实施

This standard applies to separately installed Refrigerant Liquid Receivers for field-erected systems only.

Performance Rating of Refrigerant Liquid Receivers

ICS
23.020.10
CCS
J73
发布
2005
实施

Water Systems Council (WSC) PST-2000 Pressurized Water Storage Tank Standard

ICS
23.020.10
CCS
A82
发布
2005
实施

Pressurized Water Storage Tank

ICS
23.020.10
CCS
A82
发布
2005
实施

To establish a Standard for minimum performance and construction requirements for pressurized storage tanks for service in water well systems.

Pressurized Water Storage Tank

ICS
23.020.10
CCS
Q81
发布
2005
实施

This standard specifies the requirements for leak detection systems - class IV for use only with liquids as defined in the scope of EN 13352.

Leak detection systems - Part 5: Tank gauge leak detection systems; German version EN 13160-5:2004

ICS
23.020.10
CCS
P94
发布
2004-12
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved