23.040.45 塑料配件 标准查询与下载



共找到 455 条与 塑料配件 相关的标准,共 31

4.1 This test method is designed to impart tensile impact energy to a butt fused plastic pipe specimen, record the energy to fail the specimen and plot the load over time curve of the tensile test. Energy recorded at yield and rupture and the rupture mode (brittle or ductile) are used as criteria in the evaluation of the butt fusion joint. The evaluation of the force/time curve not only makes it possible to compare different butt fusion parameters but also to evaluate the rupture mode of the specimen to determine joint integrity. Each coupon's test results will usually be compared to test results for coupons machined from the base pipe material, un-fused. 4.1.1 These data are also useful for qualitative characterization and for research and development. For many materials, there may be a specification that requires the use of this test method, but with some procedural modifications that take precedence when adhering to the specification. Therefore, it is advisable to refer to that material specification before using this test method. 4.2 Tensile properties may vary with specimen preparation and with speed and environment of testing. Consequently, where precise comparative results are desired, these factors must be carefully controlled. 4.2.1 It is realized that a material cannot be tested without also testing the method of preparation of that material. Hence, when comparative tests of materials per se are desired, the greatest care must be exercised to ensure that all specimens are prepared in exactly the same way, unless the test is to include the effects of specimen preparation. While care must be taken to secure the maximum degree of uniformity in details of preparation, treatment, and handling, the exact dimensions of the test specimens are entered into the Data Acquisition System (DAS) before initiating the test. 1.1 This is a tensile impact test method that develops enough tensile impact energy at specific rates of strain to rupture standard tensile impact specimens of butt fused plastic pipe. It is used to determine the quality of PE butt fusion joints made in the field or in qualification testing. It can also be used to determine the optimum butt fusion joining parameters of PE materials. 1.2 This test method is applicable for testing pipe specimens with a diameter 2.37 in. (60.3 mm) and larger with a wall thickness from 0.25 in. (6.3 mm) and larger. Note 1: This test method is similar to ISO 13953. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This test method may be used alone or together with other test methods, to evaluate the quality of the butt fused joints. When this test, conducted at laboratory temperatures per 9.2, is combined with the elevated temperature, sustained pressure test in Specification D3035

Standard Test Method for Laboratory Testing of Polyethylene (PE) Butt Fusion Joints using Tensile-Impact Method

ICS
23.040.45
CCS
发布
2015
实施

1.1 This specification covers requirements and test methods for fabricated or molded poly(vinyl chloride) (PVC) gasketed sewer fittings to be used with piping manufactured to Specifications D3034, F679, F891 or F1760. Fabricated fittings may be manufactured from pipe, or from a combination of pipe and injection molded parts, or from injection molded parts. 1.2 The requirements of this specification are to provide fabricated or molded PVC gasketed fittings suitable for non-pressure drainage of sewage and surface water, as well as applications involving subsurface drainage. Note 1: Industrial waste lines should be installed only with the specific approval of the governing code authority when using chemicals not commonly found in drains and sewers or temperatures in excess of 140°F (60°C), or both. 1.3 Fittings produced to this specification are intended to be installed with pipe, in accordance with Practice D2321. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 The following precautionary caveat pertains to the test method portion only, Section 10, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sewer Fittings

ICS
23.040.45
CCS
发布
2015
实施

Reclaimed waste for separate box

ICS
23.040.45
CCS
发布
2014-12-31
实施
2014/12/31

ISO 727-2:2005 specifies the dimensions, in millimetres, of plain sockets (cylindrical and conical), for the inch-based pipe series, in fittings made from unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly(vinyl chloride) (PVC-C) or acrylonitrile/butadiene/styrene (ABS), intended for connecting by solvent cementing to pipes of the corresponding material for use under pressure. The resulting joint does not require mechanical anchorage.

Fittings made from unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly(vinyl chloride) (PVC-C) or acrylonitrile/butadiene/styrene (ABS) with plain sockets for pipes under pressure -- Part 2: Inch-based series

ICS
23.040.45
CCS
发布
2014-12-25
实施

ISO 13967:2009 specifies a method of determining the ring stiffness of bends and branches made from thermoplastic material and for use with plastics pipes having a circular cross-section. The method can be used to determine the stiffness of bends, equal branches and unequal branches, provided the fitting allows a diametric deflection of at least 4 %.

Thermoplastics fittings -- Determination of ring stiffness

ICS
23.040.45
CCS
发布
2014-12-25
实施

This International Standard specifies a method for testing the flexural fatigue resistance of piping assemblies under pressure. The method is applicable to polyethylene (PE) tapping tees, PE/metal transition fittings and PE branch saddles, intended for use with PE pipes having a nominal outside diameter de ≤ 63 mm. NOTE The test is based on simulating the stresses generated in practice on buried piping networks, i.e. combined bending and tensile stresses, at ambient temperature. The test is accelerated by magnifying the displacements observed in practice.

Plastics pipes and fittings -- Bending-tensile cycle test for PE/metal transition fittings, PE tapping tees and PE branch saddles

ICS
23.040.45
CCS
发布
2014-12-25
实施

This Singapore Standard applies to solvent cementing fittings and elastomeric ring seal fittings made from unplasticised polyvinyl chloride (uPVC). It is applicable to fittings in piping systems intended for the supply of water under pressure up to and including 25℃, intended for human consumption and for general purposes. It is also applicable to the conveyance of water up to and including 45℃. For temperatures between 25℃ and 45℃, Figure 1 below applies.

Specification for joints and fittings for use with unplasticised PVC pressure pipes

ICS
23.040.45
CCS
发布
2014-09-03
实施

Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing

ICS
23.040.45
CCS
G33
发布
2014-08-01
实施

Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Crosslinked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Tubing

ICS
23.040.45
CCS
发布
2014-08-01
实施

This part of ISO 15874 specifies the characteristics of fittings for polypropylene (PP) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems under design pressures and temperatures according to the class of application (see ISO 15874-1:2013, Table 1). It covers a range of service conditions (application classes) and design pressure classes. For values of TD, Tmax and Tmal in excess of those in Table 1 of ISO 15874-1:2013 do not apply. NOTE It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. It also specifies the parameters for the test methods referred to in this part of ISO 15874. In conjunction with the other parts of ISO 15874, this part of ISO 15874 is applicable to fittings made from PP and to fittings made from other materials which are intended to be fitted to pipes conforming to ISO 15874-2 for hot and cold water installations, whereby the joints conform to the requirements of ISO 15874-5. This part of ISO 15874 is applicable to fittings of the following types: — socket fusion fittings; — electro fusion fittings; — mechanical fittings; — fittings with incorporated inserts. It is also applicable to fittings made from alternative materials which when fitted to pipes conforming to ISO 15874-2, conform to the requirements of ISO 15874-5.

Plastics piping systems for hot and cold water installations - Polypropylene (PP)-Part 3: Fittings

ICS
23.040.45
CCS
发布
2014-04-02
实施

Standard Specification for ��Fiberglass�� (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe Fittings for Nonpressure Applications

ICS
23.040.45
CCS
发布
2014-04-01
实施

1.1 This specification covers plastic insert fittings for polyethylene (PE) plastic pipe, and also PVC insert fittings for PE to PVC pipe transitions. Included are requirements for materials, workmanship, dimensions, and burst pressure. 1.2 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 8199;The following safety hazards caveat pertains only to the test methods portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe

ICS
23.040.45
CCS
发布
2014
实施

1.1 This specification covers polyethylene socket-type fittings for use with outside diameter-controlled polyethylene pipe as specified by Specifications D3035 and D2513. Requirements for materials, workmanship, dimensions, and pressure performance are included. Where applicable in this specification, “ pipe” shall mean “pipe and tubing.” 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 The following safety hazards caveat pertains only to the test method portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Socket-Type Polyethylene Fittings for Outside Diameter-Controlled Polyethylene Pipe and Tubing

ICS
23.040.45
CCS
发布
2014
实施

이 표준은 KS M 3401에 규정한 수도용 경질 폴리염화비닐관의 주로 접착 접합에 사용하는 경질 폴리염화비닐 이음관 및 내충격성 경질 폴리염화비닐 이음관(이하 이음관이라 한다.)에 대하여 규정한다.

Rigid poly(vinyl chloride)(PVC-U) pipe fittings for water supply

ICS
23.040.45
CCS
G32
发布
2013/12/30
实施
2013/12/30

This part of ISO 4427 specifies the general aspects of fittings made from polyethylene (PE) for piping systems intended for the conveyance of water for human consumption, including raw water prior to treatment and water for general purposes. It also specifies the test parameters for the test methods to which it refers.

Plastics piping systems-Polyethlene (PE) pipes and fittings for water supply - Part 3: Fittings

ICS
23.040.45
CCS
发布
2013-09-09
实施

This part of ISO 21003 specifies the characteristics of fittings for multilayer piping systems intended to be used for hot and cold water installations inside buildings for the conveyance of water — whether or not the water is intended for human consumption (domestic systems) or for heating systems — under specified design pressures and temperatures appropriate to the class of application (see Table 1 of ISO 21003-1:2008). It also specifies the test parameters for the test methods referred to in this part of ISO 21003. ISO 21003 is a reference product standard. It is applicable to multilayer pipes, fittings, their joints, and also to joints with components made of other plastics and non-plastics materials intended to be used for hot and cold water installations. This part of ISO 21003 is intended for use only in conjunction with all the other parts of ISO 21003. This part of ISO 21003 covers fusion, solvent-cemented and mechanical fittings for a range of service conditions (application classes) and design pressures. It is not applicable for values of design temperature, TD, maximum design temperature, Tmax, and malfunction temperature, Tmal, in excess of those in Table 1 of ISO 21003-1:2008. NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. The polymeric materials used for the stress-designed layers are the following: polybutylene (PB), polyethylene of raised temperature resistance (PE-RT), crosslinked polyethylene (PE-X), polypropylene (PP) and chlorinated poly(vinyl chloride) (PVC-C). The PE-X used shall be fully crosslinked and shall comply with the requirements of the relevant reference product standard (ISO 15875). NOTE 2 For the purposes of ISO 21003, crosslinked polyethylene (PE-X) as well as adhesives are considered as thermoplastic materials.

Multilayer piping systems for hot and cold water installations inside buildings - Part 3: Fittings

ICS
23.040.45
CCS
发布
2013-04-01
实施

Abstract Specification of the series of diameters to be used and the dimensions, which are common to all types of PVC- and metal adaptor fittings for pipes under pressure, to achieve connection to existing metal pipes, fittings and valves.

Unplasticized polyvinyl chloride (PVC) and metal adaptor fittings for pipes under pressure - Laying lengths and size of threads - Metric series

ICS
23.040.45
CCS
发布
2013-04-01
实施

This part of ISO 22391 specifies the characteristics of fittings for piping systems made of ⎯ polyethylene of raised temperature resistance (PE-RT), Type I, and ⎯ polyethylene of raised temperature resistance (PE-RT), Type II, intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not the water is intended for human consumption (domestic systems) and for heating systems, under the design pressures and temperatures appropriate to the class of application according to ISO 22391-1. This part of ISO 22391 covers a range of service conditions (classes of application), design pressures and pipe dimension classes, and also specifies test parameters and test methods. In conjunction with the other parts of ISO 22391, it is applicable to fittings made of PE-RT, as well as to those made of other materials, intended to be fitted to pipes conforming to ISO 22391-2 for hot and cold water installations, the joints of which are in accordance with ISO 22391-5.

Plastics piping systems for hot and cold water installations - Polyethylene of raised temperature resistance (PE-RT) - Part 3: Fittings

ICS
23.040.45
CCS
发布
2013-04-01
实施

This International Standard specifies the design lengths and size of threads for polyethylene (PE)/metal adaptor fittings and polypropylene (PP)/metal adoptor fittings for pipes under pressure. It also specifies the dimensions at the socket and spigot ends of the fitting. The adaptor fittings have one plain socket or spigot for fusion jointing a PE socket or spigot to a PE pipe, or a PP socket or spigot to a PP pipe. The other component of the fitting is metal and is threaded to enable connection to metal pipes, fitting, valves and/or apparatus with pipe threads. The pressuretight joint is achieved by the compression of a gasket. Metal adaptor fittings are intended for use in pipelines for water supply.

PE/metal and PP/metal adaptor fittings for pipes for fluids under pressure - Design lengths and size of threads - Metric series

ICS
23.040.45
CCS
发布
2013-04-01
实施

This International Standard specifies two methods for assessing the effects of heating on injection-moulded thermoplastics pipe fittings — method A, using an air oven, and method B, using a liquid bath. In case of disagreement, method A is the reference method. This International Standard is applicable to cement-welded fittings as well as to flanged fittings and fittings incorporating elastomeric seals and to fittings consisting of the assembly of several moulded parts (e.g. union connectors). It is applicable to both pressure and non-pressure fittings.

Plastics piping and ducting systems - Injection-moulded thermoplastics fittings - Methods for visually assessing the effects of heating

ICS
23.040.45
CCS
发布
2013-04-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved