1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C 478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.1.1.1 These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are for information only.Note 1This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 6 psi (14 ft) without leakage when tested in accordance with Section 7. Infiltration quantities for an installed system are dependent upon many factors other than the connections between storm sewer structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific warning statement, see 7.2.4.

Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes, and Laterals

ICS
23.040.50
CCS
发布
2007-03-01
实施

This standard specifies general quality requirements and testing for plastics-mMultilayer pipes.

Multilayer pipes - Plastics-Multilayer pipes - General quality requirements and testing

ICS
23.040.50
CCS
G33
发布
2006-04
实施

This document specifies performance requirements for: — vitrified clay pipes, fittings and pipe joints as defined in EN 295-1, — special fittings, adaptors and compatible accessories as defined in EN 295-4, — perforated vitrified clay pipes and fittings as defined in EN 295-5, — vitrified clay manholes as defined in EN 295-6, — vitrified clay pipes and joints for pipe jacking as defined in EN 295-7, for buried drain or sewer systems for the conveyance of sewage and surface water (including rain water) under gravity or occasionally at low head of pressure. It specifies the evaluation of conformity for the performance requirements of products according to this document.

Vitrified clay pipes and fittings and pipe joints for drains and sewers - Performance requirements

ICS
23.040.50
CCS
Q81
发布
2005-09-29
实施
2005-09-29

Vitrified clay pipes and fittings and pipe joints for drains and sewers - Part 10: Performance requirements

ICS
23.040.50
CCS
发布
2005-08-17
实施
2005-08-17

This standard specifies general requirements and testing for Polyolefin-Aluminium-multilayer pipes.

Multilayer pipes - Polyolefin-Aluminium-Multilayer pipes - General requirements and testing

ICS
23.040.50
CCS
G33
发布
2005-08
实施

Vitrified clay pipes and fittings and pipe joints for drains and sewers - Part 10 : Performance requirements.

ICS
23.040.50
CCS
Q81
发布
2005-06-01
实施
2005-06-20

This specification covers the standardization of the pipe sizes and types of threads used to join impervious graphite pipe and fittings. The thread standards may also be applied to impervious carbon pipe and fittings. It is limited to physical dimensions.

Specification for Impervious Graphite Pipe and Threading

ICS
23.040.50
CCS
Q51
发布
2005-05-01
实施

1.1 This specification covers non-asbestos fiber-cement conduit for use in electric-power systems and communication systems. The service is for both underground and exposed conditions.1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Non-Asbestos Fiber-Cement Conduit

ICS
23.040.50
CCS
发布
2005-04-05
实施

This standard describes coextruded polyethylene (PE) composite pressure pipes with a welded aluminum tube reinforcement between the inner and outer layers of polyethylene, primarily for use as underground water service lines.

Polyethylene-Aluminum-Polyethylene & Crosslinked Polyethylene-Aluminum-Crosslinked Polyethylene Composite Pressure Pipes, 1/2 In. (12 mm) Through 2 In. (50 mm), for Water Service

ICS
23.040.50
CCS
G33
发布
2005-03-23
实施

1.1 This test method covers procedures for testing precast concrete manhole sections when using the vacuum test method to demonstrate the integrity of the installed materials and the construction procedures. This test method is used for testing concrete manhole sections utilizing mortar, mastic, or gasketed joints.1.2 This test method is intended to be used as a preliminary test to enable the installer to demonstrate the condition of the concrete manholes prior to backfill.1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.4 This test method is the companion to metric Test Method C 1244M; therefore, no SI equivalents are shown in this test method.Note 18212;Vacuum test criteria presented in this test method are similar to those in general use. The test and criteria have been widely and successfully used in testing manholes.Note 28212;The user of this test method is advised that no correlation has been found between vacuum (air) and hydrostatic tests.

Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test Prior to Backfill

ICS
23.040.50
CCS
发布
2005-01-01
实施

1.1 This specification covers requirements relating to non-asbestos fiber-cement non-pressure sewer pipe, joints, and fittings suitable for use with gravity flow, intended for sewerage and drainage applications from point of use to point of treatment or disposal. It defines certain conditions of manufacture, classification, characteristics, and acceptance tests applicable to these products. 1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. Note 18212;Rubber rings suitable for use with this pipe are covered in Specification D1869. Note 28212;This specification is issued for product standardization and purchasing purposes only, and does not include requirements for installation or the relationships between operating conditions and the strength characteristics of the various classifications of pipe. The purchaser is cautioned that he must correlate installation and operating conditions with the specified characteristics of the pipe. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Non-Asbestos Fiber-Cement Nonpressure Sewer Pipe

ICS
23.040.50
CCS
Q81
发布
2005
实施

1.1 This specification covers nonreinforced concrete pipe with rubber gasket joints to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1.1.2 This specification is the SI counterpart of Specification C 505. Note 18212;This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.

Standard Specification for Nonreinforced Concrete Irrigation Pipe With Rubber Gasket Joints [Metric]

ICS
23.040.50
CCS
Q14
发布
2005
实施

1.1 This specification covers non-asbestos fiber-cement conduit for use in electric-power systems and communication systems. The service is for both underground and exposed conditions. 1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Non-Asbestos Fiber-Cement Conduit

ICS
23.040.50
CCS
发布
2005
实施

This standard describes nine pressure classification of type 1 and type II asbestos-cement pipe, 18 in. through 42 in. (450 mm through 1, 050 mm) in diameter, for underground installation to convey water in water supply service systems.

Asbestos-Cement Transmission Pipe, 18 in through 42 in (450 mm through 1,050 mm), for Water Supply Service

ICS
23.040.50
CCS
Q14
发布
2005
实施

This standard has been prepared so that design engineers may determine the correct pressure classification of asbestos-cement transmission pipe to use under various combinations of internal pressure (static, operating, and surge) and external load (earth and superimposed live loads). Combined loading curves depicting the relationship between hydrostatic loading and external loading capabilities are included to expedite the selection of the correct pipe strength classification. This standard also presents criteria for determining the type of pipe to be used under various soil and water conditions.

Selection of Asbestos-Cement Transmission and Feeder Main Pipe, Sizes 18 in through 42 in (450 mm through 1050 mm), Practice for the

ICS
23.040.50
CCS
Q14
发布
2005
实施

1.1 This specification covers non-asbestos fiber-cement conduit for use in electric-power systems and communication systems. The service is for both underground and exposed conditions. 1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Non-Asbestos Fiber-Cement Conduit

ICS
23.040.50
CCS
Q23
发布
2005
实施

1.1 This specification covers requirements relating to non-asbestos fiber-cement non-pressure sewer pipe, joints, and fittings suitable for use with gravity flow, intended for sewerage and drainage applications from point of use to point of treatment or disposal. It defines certain conditions of manufacture, classification, characteristics, and acceptance tests applicable to these products. 1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. Note 1: Rubber rings suitable for use with this pipe are covered in Specification D1869. Note 2: This specification is issued for product standardization and purchasing purposes only, and does not include requirements for installation or the relationships between operating conditions and the strength characteristics of the various classifications of pipe. The purchaser is cautioned that he must correlate installation and operating conditions with the specified characteristics of the pipe. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Non-Asbestos Fiber-Cement Nonpressure Sewer Pipe

ICS
23.040.50
CCS
发布
2005
实施

Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers

ICS
23.040.50
CCS
发布
2004-10-01
实施

This part of BS 5911 specifies requirements and describes test methods for prestressed concrete non-pressure circular pipes and fittings with flexible joints (with seals either integrated in the units or supplied separately) and nominal sizes not exceeding DN 3200, for which the main intended use is the conveyance of sewage, rainwater and surface water under gravity or occasionally at low head of pressure, in pipelines that are generally buried. BS EN 752 , BS EN 1295-1 and BS EN 1610 deal with the planning, design, installation and testing of drains and sewers.

Concrete pipes and ancillary concrete products - Specification for prestressed non-pressure pipes and fittings with flexible joints

ICS
23.040.50
CCS
Q14
发布
2004-09-01
实施
2004-10-31

This part of BS 5911 specifies requirements and describes test methods for prestressed concrete non-pressure circular pipes and fittings with flexible joints (with seals either integrated in the units or supplied separately) and nominal sizes not exceeding DN 3200, for which the main intended use is the conveyance of sewage, rainwater and surface water under gravity or occasionally at low head of pressure, in pipelines that are generally buried. BS EN 752-2, BS EN 752-3 and BS EN 752-4, BS EN 1295-1 and BS EN 1610 deal with the planning, design, installation and testing of drains and sewers.

Concrete pipes and ancillary concrete products - Specification for prestressed non-pressure pipes and fittings with flexible joints