23.040.50 其他材料的管和配件 标准查询与下载



共找到 367 条与 其他材料的管和配件 相关的标准,共 25

Standard Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers

ICS
23.040.50
CCS
发布
2017-04-01
实施

Fibre reinforced thermosetting plastic pipes. Nondestructive testing method with manufacturing

ICS
23.040.50
CCS
发布
2017-00-00
实施
2018-02-01

Fibre reinforced thermosetting plastic pipes and pipelines. Nondestructive testing methods with exploiting

ICS
23.040.50
CCS
发布
2017-00-00
实施
2018-02-01

1.1 This specification covers steel fiber reinforced concrete pipe (SFRCP) of internal diameters 12 48 in., intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. NOTE 1—Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relation ship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification. 1.2 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.

Standard Specification for Steel Fiber Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50
CCS
发布
2016-11-01
实施

1.1 This specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts. 1.2 This specification is the SI companion to Specification C76; therefore, no inch-pound equivalents are presented in this specification. Reinforced concrete pipe that conform to the requirements of C76 are acceptable under this Specification C76M unless prohibited by the Owner. Note 1: This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, controlled manufacture in the plant, and care and installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site. Note 2: Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (ASTM Designation C655M).

Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)

ICS
23.040.50
CCS
发布
2016-11-01
实施

1.1 This specification covers the standardization of the pipe sizes and types of threads used to join impervious graphite pipe and fittings. The thread standards may also be applied to impervious carbon pipe and fittings. It is limited to physical dimensions.

Standard Specification for Impervious Graphite Pipe and Threading

ICS
23.040.50
CCS
发布
2016-01-01
实施

1.1 This specification establishes the criteria for the manufacture, quality assurance testing, inspection, installation, field acceptance testing, and product marking of vitrified clay jacking pipe to be used in microtunneling, the pilot tube method, sliplining, pipe bursting, and in casings and tunnels for the conveyance of sewage, industrial wastes, and storm water. 1.1.1 Sections 3 through 7 and 9 of this specification contain manufacturing, quality assurance testing, inspection, and product marking criteria which are applicable to vitrified clay pipe prior to installation. 1.1.2 Section 8 of this specification contains criteria for the installation and field acceptance testing of vitrified clay pipe. 1.2 This specification also covers materials and test requirements for jointing of the pipe. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Vitrified Clay Pipe and Joints for Use in Microtunneling, Sliplining, Pipe Bursting, and Tunnels

ICS
23.040.50
CCS
Q14;Q31
发布
2016
实施

1.1 This specification covers single-cell precast reinforced concrete box sections cast monolithically and intended to be used for the construction of culverts and for the conveyance of storm water industrial wastes and sewage. 1.2 This specification is the SI companion to Specification C1433. Note 1: This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete box sections specified herein is cautioned that he must properly correlate the loading conditions and the field requirements with the box section specified and provide for inspection at the construction site.

Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers (Metric)

ICS
23.040.50
CCS
Q14
发布
2016
实施

1.1 This specification covers single-cell precast reinforced concrete box sections cast monolithically and intended to be used for the construction of culverts and for the conveyance of storm water industrial wastes and sewage. 1.2 This specification is the companion to SI Specification C1433M; therefore, no SI equivalents are shown in this specification. Note 1: This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete box sections specified herein is cautioned that proper correlation of the loading conditions and the field requirements with the box section specified, and provision for inspection at the construction site, are required.

Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers

ICS
23.040.50
CCS
Q14
发布
2016
实施

1.1 These test methods cover testing of concrete pipe, manhole sections, and tile. The test methods described are used in production testing and acceptance testing to evaluate the properties provided for in the specifications. 1.2 The test methods appear in the following order:   Section External Load Crushing Strength 4 Flat Slab Top 5 Core Strength 6 Absorption 7 Hydrostatic 8 Permeability 9 Manhole Step 10 Cylinder 11 Gasket Lubricant 12 Joint Shear 13 Alkalinity 14 Gasket Measurements 15 1.3 The test specimens shall not have been exposed to a temperature below 4°C for the 24 h immediately preceding the test.

Standard Test Methods for Concrete Pipe, Manhole Sections, or Tile (Metric)

ICS
23.040.50
CCS
发布
2016
实施

1.1 These test methods cover testing of concrete pipe, manhole sections, and tile. The test methods described are used in production testing and acceptance testing to evaluate the properties provided for in the specifications. 1.2 The test methods appear in the following order:   Section External Load Crushing Strength  4 Flat Slab Top  5 Core Strength  6 Absorption  7 Hydrostatic  8 Permeability Manhole Step  9 10 Cylinder Strength 11 Gasket Lubricant 12 Joint Shear 13 Alkalinity 14 Gasket Measurements 15 1.3 The test specimens shall not have been exposed to a temperature below 40°F for the 24 h immediately preceding the test. 1.4 If any test specimen fails because of mechanical reasons such as failure of testing equipment or improper specimen preparation, it s......

Standard Test Methods for Concrete Pipe, Manhole Sections, or Tile

ICS
23.040.50
CCS
发布
2016
实施

1.1 This specification establishes the criteria for the manufacture, quality assurance testing, inspection, installation, field acceptance testing, and product marking of vitrified clay jacking pipe to be used in microtunneling, the pilot tube method, sliplining, pipe bursting, and in casings and tunnels for the conveyance of sewage, industrial wastes, and storm water. 1.1.1 Sections 3 through 7 and 9 of this specification contain manufacturing, quality assurance testing, inspection, and product marking criteria which are applicable to vitrified clay pipe prior to installation. 1.1.2 Section 8 of this specification contains criteria for the installation and field acceptance testing of vitrified clay pipe. 1.2 This specification also covers materials and test requirements for jointing of the pipe. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Vitrified Clay Pipe and Joints for Use in Microtunneling, Sliplining, Pipe Bursting, and Tunnels

ICS
23.040.50
CCS
发布
2016
实施

1.1 This specification covers nonreinforced concrete pipe designed for specified strengths and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 A complete companion to Specification C985 has been developed, C985M; therefore, no metric equivalents are presented in this specification. Note 1: This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load conditions and the designated strength of the pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the concrete pipe specified herein is cautioned that he must correlate the field requirements with the pipe strength specified and provide inspection at the construction site.

Standard Specification for Nonreinforced Concrete Specified Strength Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50
CCS
发布
2015-10-01
实施

Transport and storage of pipes, fittings and prefabricated manhole components made of concrete and steel reinforced concrete

ICS
23.040.50
CCS
Q14
发布
2015-09
实施

Drainage pipes for landfills - Part 3: Drainage pipes and fittings and their joints made from concrete

ICS
23.040.50
CCS
Q14
发布
2015-01
实施

1.1 This specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts. 1.2 This specification is the SI companion to Specification C76; therefore, no inch-pound equivalents are presented in this specification. Reinforced concrete pipe that conform to the requirements of C76 are acceptable under this Specification C76M unless prohibited by the Owner. Note 1: This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, controlled manufacture in the plant, and care and installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site. Note 2: Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (ASTM Designation C655M).

Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)

ICS
23.040.50
CCS
发布
2015
实施

1.1 This specification covers nonreinforced concrete pipe designed for specified strengths and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 This specification is the metric counterpart of Specification C985. Note 1: This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load conditions and the designated strength of the pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the concrete pipe specified herein is cautioned that he must correlate the field requirements with the pipe strength specified and provide inspection at the construction site.

Standard Specification for Nonreinforced Concrete Specified Strength Culvert, Storm Drain, and Sewer Pipe (Metric)

ICS
23.040.50
CCS
发布
2015
实施

1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 This specification is the SI companion to Specification C655; therefore, no inch-pound equivalents are presented in this specification. Reinforced concrete pipe that conform to the requirements of C655 are acceptable under this Specification C655M unless prohibited by the Owner. Note 1: Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.

Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe (Metric)

ICS
23.040.50
CCS
发布
2015
实施

1.1 These test methods cover testing of concrete pipe, manhole sections, and tile. The test methods described are used in production testing and acceptance testing to evaluate the properties provided for in the specifications. 1.2 The test methods appear in the following order:   Section External Load Crushing Strength  4 Flat Slab Top  5 Core Strength  6 Absorption  7 Hydrostatic  8 Permeability Manhole Step  9 10 Cylinder Strength 11 Gasket Lubricant 12 Joint Shear 13 Alkalinity 14 Gasket Measurements 15 1.3 The test specimens shall not have been exposed to a temperature below 40°F for the 24 h immediately preceding the test. 1.4 If any test specimen fails because of mechanical reasons such as failure of testing equipment or improper specimen preparation, it s......

Standard Test Methods for Concrete Pipe, Manhole Sections, or Tile

ICS
23.040.50
CCS
发布
2015
实施

1.1 This specification covers nonreinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. 1.2 This specification is the metric counterpart of Specification C14. Note 1: This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of pipe specified and provide for or require inspection at the construction site.

Standard Specification for Nonreinforced Concrete Sewer, Storm Drain, and Culvert Pipe (Metric)

ICS
23.040.50
CCS
发布
2015
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号