Guide for the maintenance of silicone transformer liquids; identical with IEC 60944:1988
Moisture has an adverse effect on the dielectric strength, dielectric loss, dc resistivity, and aging characteristics of oil-impregnated cellulosic insulating materials. When cellulosic insulation such as paper and pressboard are impregnated with and immersed in oil, there is an interchange of moisture between the cellulose and oil until they attain equilibrium with respect to their relative saturations with moisture. Considerable care should be taken in using these test methods to measure the water content of dry (<0.5 %) paper and board. Contamination of material by water from the surroundings during sampling and handling may be both rapid and significant in the case of dry test specimens. This is an even greater concern with cellulose insulation prior to oil impregnation.1.1 These test methods cover the determination of the weight percent of water in new or aged, oil-impregnated electrical insulation. These test methods depend on solvent extraction of the water at room temperature. The range from 0.1 to 7.0% water has been explored. 1.2 There are four test methods, A, B, C, and D. Methods A and B for thin paper and dense materials, respectively, are manual methods for solvent extraction of water from the specimens. Titration is used to determine the amount of water. Method C uses automatic titration to determine the amount of water. Method D is a direct automated method for extraction and detection of the water. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Test Methods for Moisture Content of Oil-Impregnated Cellulosic Insulation
Dimensions of tubes, pins and rods of ferromagnetic oxides
The standard describes a method for assessing the changes in activity of pour point depressant additives in inhibited and uninhibited mineral insulating oils when aged in the presence of insulating kraft paper.
Method for evaluating the low temperature flow properties of mineral insulation oils after ageing
This European Standard describes three test methods using the same apparatus for evaluating the oxidation stability of mineral insulating oils and of hydrocarbon-based insulating liquids.
Unused hydrocarbon-based insulation liquids -Test methods for evaluating the oxidation stability
Method for evaluating the low temperature flow properties of mineral insulating oils after ageing (IEC 61065:1991); German version EN 61065:1993
Specifications and test methods for liquids intended for use as insulants in electrical equipment.
Insulating liquids - Specifications for unused liquids based on synthetic aromatic hydrocarbons
Analysis by high performance liquid chromatography (HPLC) of these compounds resulting from degradation of cellulosic insulation.
Mineral insulating oils. Methods for the determination of 2-furfural and related compounds
Mineral insulating oils. Methods for the determination of 2-furfural and related compounds.
Specification for unused insulating mineral oils for cables with oil ducts (IEC 60465:1988); German version EN 60465:1990
Classification of insulating liquids according to fire-point and net calorific value (IEC 61100:1992); German version EN 61100:1992
Test method for the determination of oxygen index of insulating liquids (IEC 61144:1992); German version EN 61144:1993
This is Technical Corrigendum 1 to IEC 61065-1991 (Method for evaluating the low temperature flow properties of mineral insulating oils after ageing)
Method for evaluating the low temperature flow properties of mineral insulating oils after ageing
Specifications for silicone liquids for electrical purposes
Provides a guide for handling, maintaining, reconditioning and assessing quality of silicone liquids in transformers rated up to 35 kV.
Guide for the maintenance of silicone transformer liquids
Specifications for silicone liquids for electrical purposes.
Insulating liquids - Determination of the partial discharge inception voltage (PDIV) - Test procedure
The principle of the method specified is pouring the insulating liquid into the test cell, increasing a power-frequency a.c. voltage at a constant rate, monitoring the appearance of discharges by an appropriate partial discharges measuring device, record
Insulating liquids; determination of the partial discharge inception voltage (PDIV); test procedure
Specifies test methods for the analysis of 2-furfural and related furan compounds resulting from the degradation of cellulosic insulation and found in mineral insulating oil samples taken from electrical equipment. The compounds are analysed by high perf
Mineral insulating oils; methods for the determination of 2-furfural and related compounds
Covers specifications and test methods for identification and delivery, appearance, density, kinematic viscosity, flash-point, pour-point, neutralization value, chlorine content, water content, corrosive sulphur, breakdown voltage, dielectric dissipation
Insulating liquids; specifications for unused liquids based on synthetic aromatic hydrocarbons