共找到 649 条与 电线和电缆 相关的标准,共 44 页
This Section contains the Recommendations on physical transmission media, both for the analogue or digital mode. It does not deal with open-wire lines or radio relays. It relates to VF cables only as physical transmission media in the digital mode.
Terminology for Cables - Transmission Media Characteristics (Study Group XV) 6 pp
Characteristics of Symmetric Cable Pairs for Analogue Transmission - Transmission Media Characteristics (Study Group XV) 5 pp
Characteristics of Symmetric Cable Pairs for Analogue Transmission - Transmission Media Characteristics (Study Group XV) 5 pp
Metallic cable conductor terminations are installed at various locations within the cable network. The type of terminal and termination device utilized at these locations is dependent on various factors relating to the specific installation
METHODS OF TERMINATING METALLIC CABLE CONDUCTORS
Bonds should not be installed between buried structures and power supply cables and equipment unless it is safe to do so in the event of a fault on the power supply system and it is in accordance with local and national safety rules.
CORROSION CAUSED BY ALTERNATING CURRENT
Application of Joint Cathodic Protection - Construction, Installation and Protection of Cable and Other Elements of Outside Plant (Study Group VI) 2 pp
Application of Joint Cathodic Protection
Unprotected steel is particularly vulnerable to corrosion attack and the protection provided usually consists of a layer of compound in which may be embedded plastic tapes so that the corrugations are completely filled. An outer sheath of polyethylene o
Methods of Keeping Cables Under Gas Pressure
The methods used for the jointing of aluminium sheaths must meet the conditions recommended in the booklet cited in [4].
Cable Sheaths Made of Metals Other Than Lead or Aluminium
Because of the technological progress made in the use of aluminium, aluminium cable sheaths are being used on an increasing scale and their favourable characteristics can now be fully exploited.
Aluminium Cable Sheaths
Because of the technological progress made in the use of aluminium, aluminium cable sheaths are being used on an increasing scale and their favourable characteristics can now be fully exploited.
Armouring of Cables
Impregnation of Wooden Poles - Construction, Installation and Protection of Cable and Other Elements of Outside Plant (Study Group VI) 1 pp
Impregnation of Wooden Poles
Construction,Installation and Protection of Telecommunication Cables in Public Networks - Construction, Installation and Protection of Cable and Other Elements of Outside Plant (Study Group VI) 1 pp
Construction Installation and Protection of Telecommunication Cables in Public Networks
Power cables should generally be buried deeper than telecommunication cables.
JOINT USE OF TRENCHES AND TUNNELS FOR TELECOMMUNICATION AND POWER CABLES Study Group V
The screening effect produced by the metal screen of a cable mainly depends on: the frequency of the induced e.m.f. The limitation of this e.m.f. mains frequency (16 2/3 Hz, 50 Hz, 60 Hz) is therefore a determining factor in the choice of a cable from t
PROVISION OF A METALLIC SCREEN IN PLASTIC-SHEATHED CABLES
CCITT manual Directives concerning the protection of telecommunication lines against harmful effects fiom electric power and electrijìed railway lines, Vol. VI, ITU, Geneva, 1988.
INDUCED VOLTAGES IN CABLES WITH PLASTIC - INSULATED CONDUCTORS
In certain unfavourable circumstances, sudden transient voltages of exceptionally high instantaneous amplitude, of the order of 1 kV for example, may occur across a telephone set which is normally connected to a metal wire line, as a result of electromag
SEPARATION IN THE SOIL BETWEEN TELECOMMUNICATION CABLES AND EARTHING SYSTEM OF POWER FACILITIES
The digital multiplexing strategy is based on the use of positive justification and combines four 139 264 kbit/s tributaries into one composite signal.
DIGITAL LINE SYSTEMS BASED ON THE 2048 kbit/s HIERARCHY ON COAXIAL PAIR CABLES
This Recornmenution covers digital line systems for the transmission of signu based on the 1 44 736 kbit/s97 728 kbit/s hierarchy on coaxial pair cables and includes systems conveying the following bit rates
DIGITAL LINE SYSTEMS BASED ON THE 1544 kbit/s HIERARCHY ON COAXIAL PAIR CABLES
This Recommendation covers digital line systems for the transmission of signals based on the 1544 kbit/s hierarchy on symmetric pair cables and includes systems operating at the following bit rates: 1544 kbit/s, 3 152 kbit/s, 63 12 kbit/s.
DIGITAL LINE SYSTEMS BASED ON THE 1544 KBIT/S HIERARCHY ON SYMMETRIC PAIR CABLES
MIL-C-l4242B(MU), dated 20 April 1967, and Amendment 3, dated 16 June 1970,have been reviewed and determined to be still current.
CABLE ASSEMBLIES, FUZE CONTROL
本标准适用于交流600伏及以下低压线路或电讯、仪表线路用固定设的镀锡铜芯105℃聚氯乙烯(PVC)绝缘尼龙护套电线。
Tinned copper-core PVC insulated nylon sheathed electric wire for aviation