1.1 This Standard covers receptacles with attachment plugs; receptacles with attachment plugs interlocked with circuit breakers; receptacles with attachment plugs interlocked with switches; and cable and cord connectors, couplers, and flanged equipment power inlets and flanged equipment power outlets with ratings as specified in Clause 1.2 intended for connection to copper conductors only and for installation and use in the following hazardous locations in accordance with the Rules of Canadian Electrical Code, Part I and CSA M421: a) Class I, Division 1, Groups A, B, C, and D; b) Class I, Division 2, Groups A, B, C, and D; c) Class II, Groups F and G; and d) Class III. 1.2 This Standard covers a) Class I, Division 1 and Class II devices rated not more than 600 A or not more than 600 V ac or not more than 250 V dc; b) Class I, Division 2 devices rated not more than 1200 A and not more than 1000 V ac or not more than 1000 V dc; and c) equipment for gaseous mines rated not more than 1100 V ac. 1.3 This Standard does not cover plug and receptacle/connector combinations that do not incorporate either a delayed withdrawal, an interlock mechanism or other retaining device. Note: In this Standard, devices that are classified for Group G locations are acceptable for use in atmospheres containing coal or coke dust. 1.4 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Plugs, connectors, receptacles, and similar wiring devices for use in hazardous locations

ICS
29.120.30
CCS
发布
2018-01-01
实施

This standard determines plug socket and plug that are applicable as plug coupling between the pH combination electrodes specified in DIN 19263 without temperature sensor and the measuring cable of the pH-measuring amplifier (e. g. specified in DIN 19265.)

pH measurement - Plug socket and plug shielded for pH electrodes and pH combination electrodes

ICS
29.120.30
CCS
发布
2018
实施

This part of the lEC 60320 sets the dimensions for appliance couplers for two poles and two poles with earth contact – for the connection of electrical devices for household and similar onto the mains supply and – for the interconnection of the electrical supply to appliance or equipment – and dimensions for gauges.

Appliance couplers for household and similar general purposes - Part 3: Standard sheets and gauges

ICS
29.120.30
CCS
发布
2017-10-03
实施

This clause of Part 1 is applicable.

Plugs, socket-outlets and ship couplers for high-voltage shore connection systems (HVSC-SYSTEMS) - Part 2: Dimensional compatibility and interchangeability requirements for accessories to be used by various types of ships

ICS
29.120.30
CCS
发布
2017-10-03
实施

This part of IEC 62196 is applicable to vehicle couplers with pins and contact-tubes of standardized configuration, herein also referred to as “accessories”, intended for use in electric vehicle conductive charging systems which incorporate control means, with rated operating voltage up to 1 500 V d.c. and rated current up to 250 A, and 1 000 V a.c. and rated current up to 250 A. This part of IEC 62196 applies to high power d.c. interfaces and combined a.c./d.c. interfaces of vehicle couplers specified in IEC 62196-1:2014, and intended for use in conductive charging systems for circuits specified in IEC 61851-1:2010, and IEC 61851-23:2014. The d.c. vehicle connectors covered by this part of the standard are used only in charging mode 4, according to Case C in Clause 6.2 of IEC 61851-1:2010, Figure 3 in Clause 6.3.1 of IEC 61851-1:2010 and IEC 62196-2:2011. The d.c. vehicle inlets covered by this part of the standard are used only in charging mode 4, according to Case C in Clause 6.2 of IEC 61851-1:2010, Figure 3 in Clause 6.3.1 of IEC 61851-1:2010. These vehicle couplers are intended to be used for circuits similar to those specified in IEC 61851-23 which operate at different voltages and which may include ELV and communication signals. This part of IEC 62196 applies to the vehicle couplers to be used in an ambient temperature of between –30 °C and +50 °C. NOTE 1 In some countries, other requirements may apply. NOTE 2 In the following country, –35 °C applies: SE. These vehicle couplers are intended to be connected only to cables with copper or copperalloy conductors.

Plugs, socket-outlets, vehicle connectors and vehicle inlets - Conductive charging of electric vehicles - Part 3: Dimensional compatibility and interchangeability requirements for d.c. and a.c./d.c. pin and contact-tube vehicle couplers

ICS
29.120.30
CCS
发布
2017-10-03
实施

This standard applies to fixed socket-outlets for a.c. only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.

Plugs and socket-outlets for household and similar purposes - Part 1: General requirements on fixed socket-outlets; Amendment A1

ICS
29.120.30
CCS
L23
发布
2017-09-00
实施
2017-09-01

This standard applies to plugs and portable socket-outlets for a.c. only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.

Plugs and socket-outlets for household and similar purposes - Part 2-1: General requirements on Plugs and portable socket-outlets; Amendment A1

ICS
29.120.30
CCS
L23
发布
2017-09-00
实施
2017-09-01

基本结构、环境条件、外观及尺寸要求、电气参数、高压安全、耐电压、绝缘电阻、电磁兼容、防护等级、阻燃、盐雾、气候老化、耐潮湿、工作寿命

AC Charging Socket For Electric Vehicles

ICS
29.120.30
CCS
C3824
发布
2017-07-20
实施
2017-08-22

Replacement: This part of IEC 60884 applies to adaptors for a.c. only with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors. This document also applies to travel adaptors (see Annex AA). For travel adaptors the scope is limited to a voltage rating greater than 50 V but not exceeding 250 V and to a current rating not exceeding 20 A. Travel adaptors allowing the simultaneous connection of two or more plugs are not covered by this document. NOTE 1 In the following countries the use of non-shuttered adaptors is not allowed: BE, CN, DK, ES, FR, IT, NO, MY, PT, SE, SG, UK, ZA. NOTE 2 In the following countries adaptors having IP classes below IPX4 shall be provided with shutters: FI. NOTE 3 In the following countries fused adaptors are not allowed: ZA. NOTE 4 In the following countries rewirable external flexible cables connected to adaptors are not allowed: ZA. NOTE 5 In the following countries, travel adaptors shall not be used for charging electrical vehicles: CH, SE. This document covers the requirements for adaptors with additional functions, however the additional function itself is not covered by this standard. NOTE 6 Examples of additional functions are electronic power supply units, dimmers, timers, protection devices, infrared switches. This document does not apply to adaptors incorporating connectors according to IEC 60320 (all parts). Adaptors complying with this document are suitable for use at ambient temperatures not normally exceeding +40 °C, but their average over a period of 24 h does not exceed +35 °C, with a lower limit of the ambient air temperature of -5 °C. NOTE 7 Tests for temperatures below normal range are under consideration.

Plugs and socket-outlets for household and similar purposes - Part 2-5: Particular requirements for adaptors

ICS
29.120.30
CCS
K30
发布
2017-05
实施

Low-voltage docking connectors for removable energy storage units

ICS
29.120.30
CCS
L23
发布
2017-04-30
实施
2017-04-30

This document applies to docking connectors (hereinafter referred to as accessories) incorporated in or fixed to electrical equipment, intended to connect removable energy storage units to a dedicated electric power conversion unit, to an energy consuming unit or to another energy storage unit. These accessories are intended for DC and may include an earth1 contact and/or optional auxiliary contacts for signaling and data. These accessories have a rated current of up to 800 A and rated operating voltages not exceeding 1000 V DC. These accessories are not suitable for mating or unmating under load. These accessories are intended to be installed by instructed persons (IEC 60050-195:1998, 195-04-02) or skilled persons (IEC 60050-195:1998, 195-04-01) only. The list of preferred ratings is not intended to exclude other ratings. This document applies to accessories for use under environmental conditions as described in Clause 32. These accessories are intended to be connected to current carrying parts in copper or copper alloy only, plated or not plated. This document also applies to accessories intended to be used at extra-low voltage. In locations where special conditions prevail, for example on board vehicles, additional requirements may apply. These accessories are intended to be used with a specific charging system. NOTE For conditions other than operation, additional requirements could be applicable, for instance IEC 62133 and the UN Recommendations on the Transport of Dangerous Goods section 38.338.3.

Low-voltage docking connectors for removable energy storage units

ICS
29.120.30
CCS
L24
发布
2017-03
实施

Plugs and socket-outlets for household and similar purposes; Supplement 1: Changes planned for the future in order to align IEC 60884-1 with the requirements of IEC 60228, IEC 60998 and IEC 60999

ICS
29.120.30
CCS
发布
2017-02
实施

This part of the lEC 60320 sets the general requirements for appliance couplers for two poles and two poles with earth contact and for the connection of electrical devices for household and similar onto the mains supply.

Appliance couplers for household and similar general purposes - Part 1: General requirements (IEC 23G/383/CD:2017)

ICS
29.120.30
CCS
发布
2017
实施

This part of the lEC 60320 sets the dimensions for appliance couplers for two poles and two poles with earth contact - for the connection of electrical devices for household and similar onto the mains supply and - for the interconnection of the electrical supply to appliance or equipment - and dimensions for gauges.

Appliance couplers for household and similar general purposes - Part 3: Standard sheets and gauges (IEC 23G/384/CD:2017)

ICS
29.120.30
CCS
发布
2017
实施

This clause of Part 1 is applicable except as follows: Replacement: Replace the first paragraph with the following: This part of IEC 62735, which is a technical specification, applies to plugs and fixed socket- outlets for class I equipment with two active contacts plus an earthing contact, a rated power of 5,2 kW and a rated voltage range from 294 V to 400 V d.c. They are intended to power d.c. information and communication technology equipment only. The 2,6 kW system complying with Part 1 is safely compatible with the system complying with this part as it is possible to insert the 2,6 kW plug in the 5,2 kW socket-outlet but it is not possible to insert the 5,2 kW plug into the 2,6 kW socket-outlet. Replace the third paragraph with the following: The maximum current for the plug and the socket-outlet is 13 A when the voltage between live contacts is 400 V d.c; 17,6 A when the voltage between live contacts is 294 V d.c. and can rise up to 20 A when the voltage between live contacts decreases to 260 V d.c. for 10 min maximum. Replace, in the 6th paragraph, the second dash with; an overcurrent protection (of 17,6 A or less for each socket-outlet or multiple socket- outlet).

Direct current (DC) plugs and socket-outlets for information and communication technology (ICT) equipment installed in data centres and telecom central offices - Part 2: Plug and socket-outlet system

ICS
29.120.30
CCS
L23
发布
2016-12-14
实施

Plugs, socket-outlets and ship couplers for high-voltage shore connection systems (HVSC-systems). Dimensional compatibility and interchangeability requirements for accessories to be used by various types of ships

ICS
29.120.30
CCS
U62
发布
2016-11-30
实施
2016-11-30

Low-voltage withdrawable complete sets of switchgear and control equipment auxiliary circuit connectors

ICS
29.120.30
CCS
K30
发布
2016-10-22
实施
2017-04-01

Connectors for main circuits of low-voltage withdrawable complete sets of switchgear and control equipment

ICS
29.120.30
CCS
K30
发布
2016-10-22
实施
2017-04-01

Conversion adaptors for industrial use; German version EN 50250:2002 + Cor.:2007 + A1:2015

ICS
29.120.30
CCS
K31
发布
2016-10
实施

13 A plugs, socket-outlets, adaptors and connection units. Part 5: Specification for fused conversion plugs

ICS
29.120.30
CCS
K30
发布
2016-08-31
实施
2016-08-31