共找到 191 条与 相关的标准,共 13 页
Supplement to IEEE standard for metal-clad and station-type cubicle switchgear: Current transformer accuracies
Requirements for secondary network protectors
AC load break switches for 3.3 kV or 6.6 kV
Covers the following types of enclosed low-voltage dc power circuit breakers: a) stationary or drawout type of one- or two-pole construction; b) having one or more rated maximum voltages of 3200 V, 1600 V, 1200 V, 1000 V, 800 V, 325 V, or 300V for applications on systems having nominal voltages of 3000V, 1500 V, 1000 V, 850 V, 750 V, 275 V, or 250V; c) manually-operated or power-operated; and d) with or without overcurrent trip devices.
Low-voltage dc power circuit breakers used in enclosures
Low-voltage switchgear and controlgear; part 5: control circuit devices and switching elements; section 2: proximity switches
This Korean Industrial Standard specifies cam operated control switches(1) intended for use in circuits of not more than 600V a.c. (at a frequency of 50Hz or 60Hz) or of not more than 250V d.c. (hereafter referred to as the "switches"). Note (1) The cam operated control switches mentioned here are the cam operated switches having contact elements that are intended to be installed in industrial switchgear or control gear, to perform control transmission of signals, interlocking, etc. of the said equipment.
Cam operated control switches
Assemblies for Construction Sites (ACS); incoming supply and metering ACS 400 V, 100 A, 250 A and 400 A; secondary metering
Assemblies for Construction Sites (ACS); incoming supply and metering ACS 400 V; secondary metering, internal wiring
The document applies to incoming supply and metering ACS 400 V (630 A secondary metering). The object is to lay down the built-in components in accordance with EN 60439-4-1990, sub-clause 9.1 and the dimensions.#,,#
Assemblies for Construction Sites (ACS); incoming supply and metering ACS 400 V, 630 A; secondary metering
This document applies to incoming supply and metering ACS 400 V (direct metering up to 100 A). The object is to lay down the built in components in accordance with EN 60439-4-1990, sub-clause 9.1 and the dimensions.#,,#
Assemblies for Construction Sites (ACS); incoming supply and metering ACS 400 V; direct metering up to 100 A
이 규격은 주파수 60Hz의 교류 또는 직류 300V 이하의 주로 공업용 제어회로에 사용하
Motor Driven Timer
Specification for gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
AC load break switches with tripping device for 3.3 kV or 6.6 kV
This standard applies to lamellar flexible expansion joints. The object of this is to state dimensions, materials, constructional requirements and tests.
Expansion joints for busbars and flat terminals; lamellar flexible
This standard applies to lamellar high flexible expansion joints. The opject of this is to state dimensions, materials, constructional requirements and tests.
Expansion joints for busbars and flat terminals; lamellar high flexible
이 규격은 주로 옥내에서 주파수 60Hz의 교류 600V 이하인 전로에 사용하는 퓨우즈 있
Enclosed Switches for Low Voltage Circuits (AC 600V and below)
이 규격은 교류 250V 이하의 단상 2선식 및 3상 3선식 전로에서 주로 옥내에 인입 및
Cut-out switches
이 규격은 주파수 60HZ의 교류 250V이하인 전로에서 주로 옥내에 사용하는고리퓨우즈붙
Enclosed switches
This Korean Industrial Standard specifies front connection type knife switches with cover (hereinafter referred to as "switches"), of rated current not exceeding 100A and equipped with or without link fuses which are mainly used as the main switches, branch switches and operating switches of electric lamp, electric heating or the like, in general indoor electric circuit of frequency 60Hz and of a.c. voltage not exceeding 250V. Remarks I. Above-mentioned knife switch with cover means such a switch that a cover with slots through which the blades go in and come out is mounted at the front of knife switch with base (including fuse for the ones with fuse) to cover the live parts, barriers are provided between poles, and operation of switch can be done manually without opening the cover. 2. In this standard, units and numerical values in { } are based on the Inter-national System of Unit (SI) and are appended for reference.
Knife Switches with Cover