29.130.10 高压开关装置和控制器 标准查询与下载



共找到 858 条与 高压开关装置和控制器 相关的标准,共 58

本标准规定了高原地区高压开关柜用绝缘加强件的术语和定义、标准大气条件和高原环境参数、技术要求、试验方法、检验规则、标志、包装、运输和贮存等。本标准适用于安装地点海拔高度 1 000 m~5 000 m,设备电压等级为35 kV 及以下、频率50 Hz户内高压开关柜用绝缘加强件。

Technical Requirements for Insulation Reinforcing Parts for High Voltage Switchgear in Plateau Area

ICS
29.130.10
CCS
K 43
发布
2013-08-01
实施
2013-10-01

High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers (IEC 62271-100:2008 + A1:2012); German version EN 62271-100:2009 + A1:2012

ICS
29.130.10
CCS
K43
发布
2013-08
实施
2013-08-01

High-voltage switchgear and controlgear - Part 110: Inductive load switching (IEC 62271-110:2012 + corrigendum Oct. 2012); German version EN 62271-110:2012

ICS
29.130.10
CCS
K43
发布
2013-08
实施
2013-08-01

High-voltage switchgear and controlgear - Part 101: Synthetic testing (IEC 62271-101:2012); German version EN 62271-101:2013

ICS
29.130.10
CCS
K43
发布
2013-08
实施
2013-08-01

High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV (IEC 62271-105:2012); German version EN 62271-105:2012

ICS
29.130.10
CCS
K43
发布
2013-08
实施
2013-08-01

IEC 62271-105:2012 applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses designed so as to be capable of - breaking, at the rated re

High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV

ICS
29.130.10
CCS
发布
2013-07-05
实施
2013-07-05

Applies to alternating current disconnectors and earthing switches, designed for indoor and outdoor enclosed and open terminal installations for voltages above 1 000 V and for service frequencies up to and including 60 Hz. It also applies to the operating

High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches

ICS
29.130.10
CCS
发布
2013-06-30
实施
2013-06-30

High-voltage switchgear and controlgear. Inductive load switching

ICS
29.130.10
CCS
K43
发布
2013-06-30
实施
2013-06-30

Amendment 1 - High-voltage switchgear and controlgear - Part 109: Alternating-current series capacitor by-pass switches

ICS
29.130.10
CCS
发布
2013-05-28
实施

High-voltage switchgear and controlgear - Part 109: Alternating-current series capacitor by-pass switches

ICS
29.130.10
CCS
发布
2013-05-28
实施

This part of IEC 62271 is applicable to a.c. series capacitor by-pass switches designed for outdoor installation and for operation at frequencies of 50Hz and 60 Hz on systems having voltages above 52 kV. It is only applicable to by-pass switches for use in three-phase systems. This standard is also applicable to the operating devices of by-pass switches and to their auxiliary equipment.

High-voltage switchgear and controlgear.Part 109: Alternating-current series capacitor by-pass switches

ICS
29.130.10
CCS
K43
发布
2013-05
实施

本标准规定了高压开关六氟化硫(SF)气体微水含量变送器(以下简称微水含量变送器)的术语和定义、分类与命名、基本参数、要求、试验方法、检验规则及标志、包装、运输和贮存、本标准适用于电厂、变电站等高压开关保护气体六氟化硫中微水含量检测所采用的变送器、

Transmitters for moisture content in sulfur hexafluoride gas for high voltage switches

ICS
29.130.10
CCS
K43
发布
2013-04-25
实施
2013-09-01

IEC 62271-106:2011 is applicable to a.c. contactors and/or contactor-based controllers and motor-starters designed for indoor installation and operation at frequencies up to and including 60 Hz on systems having voltages above 1 000 V but not exceeding 24 000 V. It is applicable only to three-pole devices for use in three-phase systems, and single-pole devices for use in single-phase systems. Two-pole contactors and starters for use in single-phase systems are subject to agreement between manufacturer and user. This standard cancels and replaces the second edition of IEC 60470 published in 1999. It constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60470:1999: - Scope and object: The voltage range covered by the standard was expanded from 12 kV to 24 kV. Overload relay calibration and testing is not covered by this standard. - 3 Terms and definitions: Added definitions for capacitor switching classes. - 4.1 Rated voltage: Added 15, 17,5 and 24 kV as standard voltage values. - 4.109.2 Starting duty of reduced-voltage starters: Added ratings for autotransformer and reactor starters (was in the testing section). - 4.112 Rated capacitive switching currents: Added capacitor switching current ratings. - 5.101 Protective relays: Removed the requirements for overload relays. This section is obsolete since there are only a few MV starters fitted with thermal overload relays and electronic relays have their own standards. - 6.2.5 Application of the test voltage and test conditions (former 6.2.2 b)): Changed wording of requirement for impulse across the open gap of vacuum contactors. - 6.4.2 Auxiliary circuits: The requirement for resistance checks of auxiliary circuits was deleted. - 6.5.5.104 Temperature rise of the auto transformer or reactor for two step auto transformer or reactor starters: Reworded to transfer ratings to subclause 4.109.2. - 6.102.9 Condition following making and breaking tests: Gave specific direction as to what the tolerance should be based on where the resistance was to be checked. - 6.104 Short-circuit current making and breaking tests: Clarified test conditions for short-circuit testing. - 6.109 Capacitive current switching tests: Added capacitive current switching tests. - Annex B: Added Table B.1 - Tolerances on test quantities for type test.

High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters

ICS
29.130.10
CCS
发布
2013-04-01
实施

High-voltage switchgear and controlgear. Synthetic testing

ICS
29.130.10
CCS
K43
发布
2013-03-31
实施
2013-03-31

High-voltage switchgear and controlgear -- Part 101: Synthetic testing

ICS
29.130.10
CCS
发布
2013-03-29
实施
2013-03-29

High-voltage switchgear and controlgear -- Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV

ICS
29.130.10
CCS
发布
2013-03-29
实施
2013-03-29

High-voltage switchgear and controlgear -- Part 100: Alternating-current circuit-breakers (IEC 62271-100:2008/A1:2012)

ICS
29.130.10
CCS
发布
2013-03-29
实施
2013-03-29

High-voltage switchgear and controlgear -- Part 110: Inductive load switching

ICS
29.130.10
CCS
发布
2013-03-29
实施
2013-03-29

High-voltage switchgear and controlgear - Part 110: inductive load switching

ICS
29.130.10
CCS
K43
发布
2013-03-13
实施
2013-03-13

IEC 62271-101:2012 mainly applies to a.c. circuit-breakers within the scope of IEC 62271-100. It provides the general rules for testing a.c. circuit-breakers, for making and breaking capacities over the range of test duties described in 6.102 to 6.111 of

High-voltage switchgear and controlgear - Part 101: Synthetic testing

ICS
29.130.10
CCS
发布
2013-03-02
实施
2013-03-02