29.130.10 高压开关装置和控制器 标准查询与下载



共找到 858 条与 高压开关装置和控制器 相关的标准,共 58

High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV (IEC 62271-107:2012); German version EN 62271-107:2012

ICS
29.130.10
CCS
K43
发布
2013-03
实施
2013-03-01

IEC 62271-100:2008 is applicable to a.c. circuit-breakers designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V. It is only applicable to three-pole circuit-breakers for us

High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers

ICS
29.130.10
CCS
发布
2013-02-21
实施
2013-02-21

IEC 62271-110:2012 is applicable to a.c. circuit-breakers designed for indoor or outdoor installation, for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V and applied for inductive current switching with or without add

High-voltage switchgear and controlgear - Part 110: Inductive load switching

ICS
29.130.10
CCS
发布
2013-02-03
实施
2013-02-03

This part of International Standard 62271 provides methods for the measurement of soundpressure level produced by outdoor alternating current circuit-breakers in a free-fieldenvironment. These methods may also be used indoors or in restricted field, provi

High-voltage switchgear and controlgear - Part 37-082: Standard practice for the measurement of sound pressure levels on alternating current circuit-breakers

ICS
29.130.10
CCS
发布
2013-02-03
实施
2013-02-03

High-voltage switchgear and controlgear - Part 210: Seismic qualification for metal enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV

ICS
29.130.10
CCS
K43
发布
2013-02
实施

High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV (IEC 62271-207:2012); German version EN 62271-207:2012

ICS
29.130.10
CCS
K43
发布
2013-02
实施
2013-02-01

High-voltage switchgear and controlgear. Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV

ICS
29.130.10
CCS
K43
发布
2013-01-31
实施
2013-01-31

IEC 62271-101:2012 mainly applies to a.c. circuit-breakers within the scope of IEC 62271-100. It provides the general rules for testing a.c. circuit-breakers, for making and breaking capacities over the range of test duties described in 6.102 to 6.111 of IEC 62271-100:2008, by synthetic methods. This second edition cancels and replaces the first edition published in 2007 and its Amendment 1 published in 2011. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the first edition: - addition of the new rated voltages of 1 100 kV and 1 200 kV; - revision of Annex F regarding circuit-breakers with opening resistors; - alignment with the second edition of IEC 62271-100:2008 and its Amendment 1 (2012). This publication is to be read in conjunction with IEC 62271-100:2008.

High-voltage switchgear and controlgear - Part 101: Synthetic testing

ICS
29.130.10
CCS
发布
2013-01-11
实施
2013-02-16 (7)

General Instructions for Proper Handling, Installation, Operation, and Maintenance of Panelboards Rated 600 Volts or less

ICS
29.130.10
CCS
K36
发布
2013-01-01
实施

High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV; Corrigendum 1

ICS
29.130.10
CCS
K43
发布
2013-01
实施

This part of IEC 62271 specifies requirements for gas-insulated metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pressure, for alternating current of rated voltages above 52 kV, for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. For the purpose of this standard, the terms “GIS” and “switchgear” are used for “gas-insulated metal-enclosed switchgear”. The gas-insulated metal-enclosed switchgear covered by this standard consists of individual components intended to be directly connected together and able to operate only in this manner. This standard completes and amends, if necessary, the various relevant standards applying to the individual components constituting GIS.

High-voltage switchgear and control gear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV

ICS
29.130.10
CCS
发布
2012-12-31
实施

High-voltage switchgear and controlgear -- Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV

ICS
29.130.10
CCS
发布
2012-12-21
实施
2012-12-21

High-voltage switchgear and controlgear -- Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV

ICS
29.130.10
CCS
发布
2012-12-21
实施
2012-12-21

The contents of the corrigendum of December 2012 have been included in this copy.

High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers

ICS
29.130.10
CCS
发布
2012-12-14
实施
2013-02-01 (7)

IEC 62271-105:2012 applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses designed so as to be capable of - breaking, at the rated recovery voltage, any current up to and including the rated short-circuit breaking current; - making, at the rated voltage, circuits to which the rated short-circuit breaking current applies. It does not apply to fuse-circuit-breakers, fuse-contactors, combinations for motor-circuits or to combinations incorporating single capacitor bank switches. This second edition cancels and replaces the first edition of IEC 62271-105, published in 2002, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - implementation of figures at the place where they are cited first; - renumbering of tables; - addition of some of the proposals from IEC paper 17A/852/INF; - addition of missing subclauses of IEC 62271-1; - implementation of 6.105 'Extension of validity of type tests' and consequently removing of the relevant parts in the different existing clauses; - change of 7th paragraph of 6.101.4 as there is now a definition of NSDD given in 3.7.4 of IEC 62271-1:2007. Harmonization with IEC 62271-107; - some referenced clauses in other standards like IEC 60282-1 were changed and therefore changed the editions under 1.2 to the ones referred to; - addition of a new Annex C defining tolerances.

High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV

ICS
29.130.10
CCS
发布
2012-12-14
实施
2013-02-01 (7)

High-voltage switchgear and controlgear - Part 306: Guide to IEC 62271-100, IEC 62271-1 and other IEC standards related to alternating current circuit- breakers

ICS
29.130.10
CCS
K43
发布
2012-12
实施

High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers; Amendment 1 Corrigendum 1

ICS
29.130.10
CCS
K43
发布
2012-12
实施

High-voltage switchgear and controlgear - Part 207: seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV

ICS
29.130.10
CCS
K43
发布
2012-11-01
实施
2012-11-24

High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV (IEC 62271-203:2011); German version EN 62271-203:2012

ICS
29.130.10
CCS
K43
发布
2012-11
实施
2012-11-01

High-voltage switchgear and controlgear - Part 37-082: Standard practice for the measurement of sound pressure levels on alternating current circuit-breakers

ICS
29.130.10
CCS
发布
2012-10-25
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号