High-voltage switchgear and controlgear - Part 1: common specifications

ICS
29.130.10
CCS
K43
发布
2012-10-01
实施
2012-10-05

This part of IEC 62271 mainly applies to a.c. circuit-breakers within the scope of IEC 62271- 100. It provides the general rules for testing a.c. circuit-breakers@ for making and breaking capacities over the range of test duties described in 6.102 to 6.111 of IEC 62271-100:2008@ by synthetic methods. It has been proven that synthetic testing is an economical and technically correct way to test high-voltage a.c. circuit-breakers according to the requirements of IEC 62271-100 and that it is equivalent to direct testing. The methods and techniques described are those in general use. The purpose of this standard is to establish criteria for synthetic testing and for the proper evaluation of results. Such criteria will establish the validity of the test method without imposing restraints on innovation of test circuitry.

High-voltage switchgear and controlgear - Part 101: Synthetic testing

ICS
29.130.10
CCS
K43
发布
2012-10
实施
2017-12-05

High-voltage switchgear and controlgear. Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV

ICS
29.130.10
CCS
K43
发布
2012-09-30
实施
2012-09-30

IEC 62271-207:2012 applies to gas-insulated switchgear assemblies for alternating current of rated voltages above 52 kV for indoor and outdoor installations, including their supporting structure. This second edition of IEC 62271-207 cancels and replaces t

High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV

ICS
29.130.10
CCS
发布
2012-09-28
实施
2012-09-28

IEC 62271-107:2012 applies to three-pole operated units for distribution systems that are functional assemblies of a circuit-switcher and current-limiting fuses designed so as to be capable of: - breaking, at the rated recovery voltage, any load or fault

High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV

ICS
29.130.10
CCS
发布
2012-09-28
实施
2012-09-28

High-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers

ICS
29.130.10
CCS
发布
2012-09-27
实施

High-voltage switchgear and controlgear - Part 37-013: Alternating-current generator circuit-breakers (IEC 17A/993/CD:2011)

ICS
29.130.10
CCS
K43
发布
2012-09
实施

This part of IEC 62271 is applicable to a.c. circuit-breakers designed for indoor or outdoor installation@ for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V and applied for inductive current switching with or without additional shortcircuit current breaking duties. The standard is applicable to circuit-breakers in accordance with IEC 62271-100 that are used to switch high-voltage motor currents and shunt reactor currents and also to high-voltage contactors used to switch high-voltage motor currents as covered by IEC 62271-106. For circuit-breakers applied to switch shunt reactor currents at rated voltages according to IEC 62271-1:2007 Tables 2a and 2b@ combined voltage tests across the isolating distance are not required (refer to 4.2). Switching unloaded transformers@ i.e. breaking transformer magnetizing current@ is not considered in this standard. The reasons for this are as follows: a) due to the non-linearity of the transformer core@ it is not possible to correctly model the switching of transformer magnetizing current using linear components in a test laboratory. Tests conducted using an available transformer@ such as a test transformer@ will only be valid for the transformer tested and cannot be representative for other transformers; b) as detailed in IEC 62271-3061@ the characteristics of this duty are usually less severe than any other inductive current switching duty. It should be noted that such a duty may produce severe overvoltages within the transformer winding(s) depending on the circuitbreaker re-ignition behaviour and transformer winding resonance frequencies. Short-line faults@ out-of-phase current making and breaking and capacitive current switching are not applicable to circuit-breakers applied to switch shunt reactors or motors. These duties are therefore not included in this standard. Subclause 1.1 of IEC 62271-100:2008 is otherwise applicable.

High-voltage switchgear and controlgear - Part 110: Inductive load switching

ICS
29.130.10
CCS
K43
发布
2012-09
实施
2017-10-10

High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers

ICS
29.130.10
CCS
K43
发布
2012-09
实施

High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers; Amendment 1

ICS
29.130.10
CCS
K43
发布
2012-09
实施
2012-09-29

"Subclause 1.1 of IEC 62271-1:2007 is not applicable@ and is replaced as follows:. This part of IEC 62271 applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and currentlimiting fuses designed so as to be capable of -breaking@ at the rated recovery voltage@ any current up to and including the rated shortcircuit breaking current; -making@ at the rated voltage@ circuits to which the rated short-circuit breaking current applies. It does not apply to fuse-circuit-breakers@ fuse-contactors@ combinations for motor-circuits or to combinations incorporating single capacitor bank switches. In this standard@ the word ""combination"" is used for a combination in which the components constitute a functional assembly. Each association of a given type of switch and a given type of fuse defines one type of combination. In practice@ different types of fuses may be combined with one type of switch@ which give several combinations with different characteristics@ in particular concerning the rated currents. Moreover@ for maintenance purposes@ the user should know the types of fuses that can be combined to a given switch without impairing compliance to the standard@ and the corresponding characteristics of the so-made combination. A switch-fuse combination is then defined by its type designation and a list of selected fuses is defined by the manufacturer@ the so-called ""reference list of fuses"". Compliance with this standard of a given combination means that every combination using one of the selected fuses is proven to be in compliance with this standard. The fuses are incorporated in order to extend the short-circuit breaking rating of the combination beyond that of the switch alone. They are fitted with strikers in order both to open automatically all three poles of the switch on the operation of a fuse and to achieve a correct operation at values of fault current above the minimum melting current but below the minimum breaking current of the fuses. In addition to the fuse strikers@ the combination may be fitted with either an over-current release or a shunt release. NOTE In this standard the term ""fuse"" is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity. This standard applies to combinations designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. Fuses are covered by IEC 60282-1. Devices that require dependent manual operation are not covered by this standard. Switches@ including their specific mechanism@ shall be in accordance with IEC 62271-103 except for the short-time current and short-circuit making requirements where the currentlimiting effects of the fuses are taken into account. Earthing switches forming an integral part of a combination are covered by IEC 62271-102."

High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV

ICS
29.130.10
CCS
K43
发布
2012-09
实施
2012-09-29

High-voltage switchgear and controlgear. Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV

ICS
29.130.10
CCS
K43
发布
2012-08-31
实施
2012-08-31

This part of IEC 62271 applies to high-voltage alternating current disconnecting circuit-breakers for operation at frequencies of 50 Hz and 60 Hz on systems having voltages of 72,5 kV and above. This standard identifies which requirements of IEC 60694, IEC 62271-100 and IEC 62271-102 standards are applicable. It also gives the additional requirements specific to these devices. This standard covers a circuit-breaker which, when in the open position, satisfies the requirements of both a circuit-breaker and a disconnector.

Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above

ICS
29.130.10
CCS
发布
2012-08-09
实施

High-voltage switchgear and controlgear - Part 102 : alternating current disconnectors and earthing switches.

ICS
29.130.10
CCS
K43
发布
2012-08-01
实施
2012-08-18

High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV (IEC 62271-200:2011); German version EN 62271-200:2012

ICS
29.130.10
CCS
K43
发布
2012-08
实施
2012-08-01

IEC 62271-207:2012 applies to gas-insulated switchgear assemblies for alternating current of rated voltages above 52 kV for indoor and outdoor installations, including their supporting structure. This second edition of IEC 62271-207 cancels and replaces the first edition published in 2007. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - modification of the minimum voltage rating from 72,5 kV to above 52 kV; - harmonisation of qualification procedures for GIS with IEEE 693:2005 Annex A and P by modifying the response spectra; - modification of the test procedures; - addition of criteria of allowed stresses; - addition of dynamic analysis CQC.

High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV

ICS
29.130.10
CCS
发布
2012-07-27
实施
2012-09-01 (7)

High-voltage switchgear and controlgear. Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV

ICS
29.130.10
CCS
K43
发布
2012-06-30
实施
2012-06-30

IEC 62271-203:2011 specifies requirements for gas-insulated metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pressure, for alternating current of rated voltages above 52 kV,

High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV

ICS
29.130.10
CCS
发布
2012-06-29
实施
2012-06-29

High-voltage switchgear and controlgear -- Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV (IEC 62271-203:2011)

ICS
29.130.10
CCS
发布
2012-06-08
实施
2012-06-08

High voltage switchgear and controlgear - Part 103 : switches for rated voltages above 1 kV up to and including 52 kV.

ICS
29.130.10
CCS
K43
发布
2012-06-01
实施
2012-06-09