29.130.10 高压开关装置和控制器 标准查询与下载



共找到 858 条与 高压开关装置和控制器 相关的标准,共 58

Surge arresters for power supply systems of electrified railways. General specifications

ICS
29.130.10
CCS
发布
2012
实施
2013-06-01

High-voltage switchgear and controlgear -- Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV (IEC 62271-204:2011)

ICS
29.130.10
CCS
发布
2011-12-30
实施
2011-12-30

本标准规定了额定电压3.6 kV及以上、额定频率50 Hz的高压交流真空开关设备用固封极柱的使用条件、额定值、设计与结构、型式试验、出厂试验、包装、运输和贮存等方面的通用要求。

Solid-insulation-embedded poles for high-voltage alternating-current vacuum switchgear

ICS
29.130.10
CCS
K43
发布
2011-12-20
实施
2012-04-01

High-voltage switchgear and controlgear -- Part 103: Switches for rated voltages above 1 kV up to and including 52 kV (IEC 62271-103:2011)

ICS
29.130.10
CCS
发布
2011-12-16
实施
2011-12-16

1.1 Scope and objectThis part of IEC 62271 is applicable to a.c. contactors and/or contactor-based controllers and motor-starters designed for indoor installation and operation at frequencies up to and including 60 Hz on systems having voltages above 1 000 V but not exceeding 24 000 V. It is applicable only to three-pole devices for use in three-phase systems, and single-pole devices for use in single-phase systems. Two-pole contactors and starters for use in singlephase systems are subject to agreement between manufacturer and user.Contactors and/or starters dealt with in this standard typically do not have adequate short-circuit interruption capability. I

High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters

ICS
29.130.10
CCS
发布
2011-12-03
实施
2011-12-03

This part of IEC 62271 applies to rigid HV gas-insulated transmission lines (GIL) in which the insulation is obtained, at least partly, by a non-corrosive insulating gas, other than air at atmospheric pressure, for alternating current of rated voltages above 52 kV, and for service frequencies up to and including 60 Hz.It is intended that this international standard be used where the provisions of IEC 62271-203 do not cover the application of GIL (see NOTE 3).At each end of the HV gas-insulated transmission line, a specific element may be used for the connection between the HV gas-insulated transmission line and other equipment like bushings, power transform

High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV

ICS
29.130.10
CCS
发布
2011-12-03
实施
2011-12-03

High-voltage switchgear and controlgear. Alternating current contactors, contactor-based controllers and motor-starters

ICS
29.130.10
CCS
K43
发布
2011-11-30
实施
2011-11-30

Applies to alternating current disconnectors and earthing switches, designed for indoor and outdoor enclosed and open terminal installations for voltages above 1 000 V and for service frequencies up to and including 60 Hz. It also applies to the operating devices of these disconnectors and earthing switches and their auxiliary equipment. Additional requirements for disconnectors and earthing switches in enclosed switchgear and controlgear are given in EN 60298, EN 60466 and EN 60517. Note: Disconnectors in which the fuse forms an integral part are not covered by this standard This first edition cancels and replaces Ed.3 of EN 60129 published in 1984, amendm

High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches

ICS
29.130.10
CCS
发布
2011-11-25
实施
2011-11-25

This part of IEC 62271 is applicable to three-phase, alternating current switches and switchdisconnectors for their switching function, having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV up to and including 52 kV and for rated frequencies from 162/3 Hz up to and including 60 Hz. This standard is also applicable to single-pole switches used on three phase systems.This standard is also applicable to the operating devices of these switches and to their auxiliary equipment.Switch-disconnectors are also covered by IEC 62271-102 for their disconnecting function.Devices that require a dependent manual cl

High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV

ICS
29.130.10
CCS
发布
2011-11-04
实施
2011-11-04

High-voltage switchgear and controlgear - Part 206: Voltage presence indicating systems for rated voltages above 1 kV and up to and including 52 kV (IEC 62271-206:2011); German version EN 62271-206:2011

ICS
29.130.10
CCS
K43
发布
2011-11
实施
2011-11-01

High-voltage switchgear and controlgear. Rigid gas-insulated transmission lines for rated voltage above 52 kV

ICS
29.130.10
CCS
K43
发布
2011-10-31
实施
2011-10-31

High-voltage switchgear and controlgear -- Part 206: Voltage presence indicating systems for rated voltages above 1 kV and up to and including 52 kV (IEC 62271-206:2011)

ICS
29.130.10
CCS
发布
2011-10-28
实施
2011-10-28

This part of IEC 62271 applies to three-pole operated units for distribution systems that are functional assemblies of a circuit-switcher and current-limiting fuses

HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR-Part 107 :Alternating current fused circuit- switchers for rated voltage above 1 KV up to and including 52 KV

ICS
29.130.10
CCS
发布
2011-10-12
实施

Applies to alternating current disconnectors and earthing switches, designed for indoor and outdoor enclosed and open terminal installations for voltages above 1 000 V and for service frequencies up to and including 60 Hz. It also applies to the operating devices of these disconnectors and earthing switches and their auxiliary equipment. Additional requirements for disconnectors and earthing switches in enclosed switchgear and controlgear are given in IEC 60298, IEC 60466 and IEC 60517. Note: Disconnectors in which the fuse forms an integral part are not covered by this standard. This first edition cancels and replaces the third edition of IEC 60129 published in 1984, amendment 1 (1992) and amendment 2 (1996) and constitutes a technical revision. In addition, it replaces IEC 61128, IEC 61129 and IEC 61259, which are hereby withdrawn and cancelled. This bilingual version (2003-07) replaces the English version. The contents of the corrigenda of April 2002, May 2003 and February 2005 have been included in this copy.

HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR-Part 102 :Alternating current disconnectors and earthing switches

ICS
29.130.10
CCS
发布
2011-10-12
实施

IEC 62271-100:2008 is applicable to a.c. circuit-breakers designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V. It is only applicable to three-pole circuit-breakers for use in three-phase systems and single-pole circuit-breakers for use in single-phase systems. This second edition cancels and replaces the first edition published in 2001 and its amendments 1 (2002) and 2 (2006). It also cancels and replaces IEC 61633 and IEC 62271-308. The main changes with respect to the previous edition are listed below: - the introduction of harmonised (IEC and IEEE) TRV waveshapes for rated voltages of 100 kV and above (amendment 1 to the first edition); - the introduction of cable and line systems with their associated TRVs for rated voltages below 100 kV (amendment 2 to the first edition); - the inclusion of IEC 61633 and IEC 62271-308. This standard shall be read in conjunction with IEC 62271-1, first edition, published in 2007.

High-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers

ICS
29.130.10
CCS
发布
2011-10-12
实施

IEC 62271-104:2009 applies to three-pole alternating current switches for rated voltages 52 kV and above, having making and breaking current ratings, for indoor and outdoor installations, and for rated frequencies up to and including 60 Hz. This standard is also applicable to the operating devices of these switches and to their auxiliary equipment. The main object of this standard is to establish requirements for switches used in transmission and distribution systems. General-purpose switches for this application are designed to comply with the following service applications: - carrying rated normal current continuously; - carrying short-circuit currents for a specified time; - switching of mainly active loads; - switching of no-load transformers; - switching of the charging current of unloaded cables, overhead lines or busbars; - switching of closed-loop circuits; - making short-circuit currents. A further object of this standard is to establish requirements for limited-purpose and special- purpose switches used in transmission and distribution systems. Limited-purpose switches shall comply with one or more of the service applications indicated above. Special-purpose switches may comply with one or more of the service applications indicated above and, in addition, shall be suitable for one or more of the following applications: - switching single capacitor banks; - switching back-to-back capacitor banks; - switching shunt reactors including secondary or tertiary reactors switched from the primary side of the transformer; - applications requiring an increased number of operating cycles; - switching under earth fault conditions in non-effectively earthed neutral systems. This standard cancels and replaces IEC 60265-2:1988. The major changes with respect to IEC 60265-2 are as follows: - alignment with IEC 62271-1 and IEC 62271-100; - requirements for capacitive current switching aligned with those in IEC 62271-100: classes C1 and C2 are introduced. This publication is to be read in conjunction with IEC 62271-1:2007, IEC 62271-100:2008, IEC 62271-102:2001 and IEC 62271-110:2005.

HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR-Part 104 :Alternating current switches for rated voltage of 52 KV and above

ICS
29.130.10
CCS
发布
2011-10-12
实施

IEC 62271-101:2006+A1:2010 mainly applies to a.c. circuit-breakers within the scope of IEC 62271-100. It provides the general rules for testing a.c. circuit-breakers, for making and breaking capacities over the range of test duties described in 6.102 to 6.111 of IEC 62271-100, by synthetic methods. The technical content is therefore identical to the base edition and its amendment and has been prepared for user convenience. A vertical line in the margin shows where the base publication has been modified by amendment 1. Additions and deletions are displayed in red, with deletions being struck through. This consolidated version consists of the first edition (2006) and its amendment 1 (2010). Therefore, no need to order amendment in addition to this publication. This publication is to be read in conjunction with IEC 62271-100:2008.

High-voltage switchgear and controlgear - Part 101: Synthetic testing

ICS
29.130.10
CCS
发布
2011-10-12
实施

This part of IEC 62271 applies to a.c. switchgear and controlgear designed for indoor and outdoor installation and for operation at service frequencies up to and including 60 Hz on systems having voltages above 1 000 V. This standard applies to all high-voltage switchgear and controlgear except as otherwise specified in the relevant IEC standards for the particular type of switchgear and controlgear.This standard cancels and replaces IEC 60694 published in 1996.

High-voltage switchgear and controlgear - Part 1: Common specifications

ICS
29.130.10
CCS
发布
2011-10-08
实施
2011-10-08

High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

ICS
29.130.10
CCS
K43
发布
2011-10
实施

High-voltage switchgear and controlgear. Switches for rated voltages above 1 kV up to and including 52 kV

ICS
29.130.10
CCS
K43
发布
2011-09-30
实施
2011-09-30