High voltage switches Part 1: Switches with rated voltages above 1 kV and below 52 kV

ICS
29.130.10
CCS
发布
2011
实施

High-voltage switchgear and controlgear -- Part 101: Synthetic testing (IEC 62271-101:2006/A1:2010)

ICS
29.130.10
CCS
发布
2010-12-15
实施
2010-12-15

This part of IEC 62271 mainly applies to a.c. circuit-breakers within the scope of IEC 62271-100. It provides the general rules for testing a.c. circuit-breakers, for making and breaking capacities over the range of test duties described in 6.102 to 6.111 of IEC 62271-100, by synthetic methods. NOTE Circuits for the test duties described in 6.111 have not yet been standardized. However, present methods are given in Annex G. It has been proven that synthetic testing is an economical and technically correct way to test high-voltage a.c. circuit-breakers according to the requirements of IEC 62271-100 and that it is equivalent to direct testing. The methods and techniques described are those in general use. The purpose of this standard is to establish criteria for synthetic testing and for the proper evaluation of results. Such criteria will establish the validity of the test method without imposing restraints on innovation of test circuitry.

High-voltage switchgear and controlgear. Part 101: Synthetic testing

ICS
29.130.10
CCS
K43
发布
2010-11-01
实施
2010-11-01

This document provides guidance upon the design, construction, specification and testing of circuit-breakers with intentional non-simultaneous pole operation which are excluded from the scope of IEC 62271-100. In all other respects the scope of this document is identical to that of IEC 62271-100. This document provides supplementary information and guidance for this type of circuit-breaker and is intended to be used in conjunction with IEC 62271-100.Intentional non-simultaneous pole operation may be implemented by mechanical or electrical means and both methods are within the scope of this document. Where the implementation is by purely electrical means for

High-voltage switchgear and controlgear - Part 302: Alternating current circuit-breakers with intentionally non-simultaneous pole operation

ICS
29.130.10
CCS
发布
2010-10-29
实施
2010-10-29

UL Standard for Safety Wired Cabinets (Seventh Edition; Reprint with revisions through and including September 16, 2013)

ICS
29.130.10
CCS
K36
发布
2010-10-26
实施

Compact Equipment Assembly for Distribution Substations (CEADS)

ICS
29.130.10
CCS
发布
2010-10-15
实施
2010-10-15

This part of IEC 62271 gives practical guidance for the evaluation and documentation of the external electromagnetic fields which are generated by HV switchgear assemblies and HV/LV prefabricated substations. Basic requirements to measure or calculate the electric and magnetic fields are summarised for switchgear assemblies covered by IEC 62271-200 and IEC 62271-201, and for prefabricated substations covered by IEC 62271-202.NOTE 1 The methods described in this technical report refer to three-phase equipment. However, themethodology may be used correspondingly for any single- or multi-phase equipment covered by this technical report.This technical report ap

High-voltage switchgear and controlgear - Part 208: Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations

ICS
29.130.10
CCS
发布
2010-10-15
实施
2010-10-15

This European Standard specifies the service conditions, rated characteristics, general structural requirements and test methods of the prefabricated assembly of the main electrical functional units of a HV/LV Distribution Substation, duly interconnected, for alternating current of rated operating voltages above 1 kV and up to and including 52 kV on the HV side, service frequency 50 Hz. This assembly is to be cable-connected to the network.This Compact Equipment Assembly for Distribution Substation (CEADS) as defined in this standard is designed and tested to be a single product with a single serial number and one set of documentation. Such equipment is del

Compact Equipment Assembly for Distribution Substations (CEADS)

ICS
29.130.10
CCS
发布
2010-09-03
实施
2010-09-03

This British Standard gives recommendations and guidance for the maintenance of electrical switchgear and controlgear having a rated a.c. or d.c. voltage above 1 kV and up to and including 36 kV. NOTE 1 This standard is not applicable to explosion protected switchgear and controlgear. Inspection and maintenance of electrical apparatus in explosive gas atmospheres is covered in BS EN 60079-17. NOTE 2 This British Standard covers applications above 1 kV. Voltages below 1 kV are considered to be low voltage in line with the European Commission Directive 73/23/EEC [1], known as the “Low voltage directive”.

Maintenance of electrical switchgear and controlgear for voltages above 1 kV and up to and including 36 kV - Code of practice

ICS
29.130.10
CCS
K43
发布
2010-08-31
实施
2010-08-31

This part of IEC 62271 gives practical guidance for the evaluation and documentation of the external electromagnetic fields which are generated by HV switchgear assemblies and HV/LV prefabricated substations. Basic requirements to measure or calculate the electric and magnetic fields are summarised for switchgear assemblies covered by IEC 62271-200 and IEC 62271-201, and for prefabricated substations covered by IEC 62271-202. This technical report applies to equipment rated for voltages up to and including 52 kV and power-frequencies from 15 Hz to 60 Hz. The electromagnetic fields which are generated by harmonics or transients are not considered in this technical report. However, the methods described are equally applicable to the harmonic fields of the power-frequency. Detailed generic information on requirements and measurements of low-frequency electromagnetic fields is given in IEC 61786. This technical report covers evaluation under factory or laboratory conditions before installation. The electric and the magnetic fields can be evaluated either by measurements or by calculations. It is not within the scope of this technical report to specify limit values of electromagnetic fields or methods for the assessment of human exposure.

High-voltage switchgear and controlgear Part 208: Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations

ICS
29.130.10
CCS
K43
发布
2010-07-31
实施
2010-07-31

Compact Equipment Assembly for Distribution Substations (CEADS).

ICS
29.130.10
CCS
K43
发布
2010-07-01
实施
2010-07-23

High-voltage switchgear and controlgear - Part 302: Alternating current circuit-breakers with intentionally non-simultaneous pole operation

ICS
29.130.10
CCS
发布
2010-06-21
实施

High-voltage switchgear and controlgear - Part 303: Use and handling of sulphur hexafluoride (SF6) (IEC/TR 62271-303:2008); German version CLC/TR 62271-303:2009

ICS
29.130.10
CCS
K43
发布
2010-06
实施
2010-06-01

This European Standard specifies the service conditions, rated characteristics, general structural requirements and test methods of the prefabricated assembly of the main electrical functional units of a HV/LV Distribution Substation, duly interconnected, for alternating current of rated operating voltages above 1 kV and up to and including 52 kV on the HV side, service frequency 50 Hz. This assembly is to be cable-connected to the network. This Compact Equipment Assembly for Distribution Substation (CEADS) as defined in this standard is designed and tested to be a single product with a single serial number and one set of documentation. Such equipment is delivered as single transport unit. For practical reasons manufacturer and user can agree to transport the unit dismantled if transport or installation of the complete CEADS is not possible. In that case suitable verification tests shall be carried out at the installation site. A CEADS is not a Distribution Substation, either prefabricated (covered by EN 62271-202) or not (covered by EN 61936-1). However CEADS is intended to become part of a Distribution Substation assembling the HV equipment, the power transformer and the LV equipment duly interconnected (see Annex C, which also explains the origin and types of CEADS). The functions of a CEADS are: – switching and control for the operation of the HV side and protection of the HV/LV transformer functional unit; – HV/LV transformation; – switching and control for the operation and protection of the LV feeders. However relevant provisions of this standard are also applicable to designs where not all of these functions exist (e.g. equipment comprising only HV/LV transformation and switching and control for the operation and protection of the LV feeder functions). For public distribution networks, CEADS are intended for installation within an indoor or outdoor closed electrical operating area (see Definition 1.3.3) forming part of a Distribution Substation. For industrial applications, such as factories, installation of CEADS outside a closed electrical operating area may be allowed provided that safety regulations are fulfilled by additional measures adopted at the installation site under the responsibility of the designer of the installation. This standard considers the potential interaction between the individual functions when closely installed and interconnected to form a type tested assembly and defines ratings, particular design and construction requirements and test procedures for this assembly.

Compact equipment assembly for distribution substations (CEADS)

ICS
29.130.10
CCS
K43
发布
2010-05-31
实施
2010-05-31

本标准规定了额定电压为72.5kV以上,频率为50Hz的户内、户外型气体绝缘金属封闭开关设备的使用条件、额定参数、设计与结构以及试验等方面的要求。 本标准适用于全部或部分采用六氟化硫气体而不是大气压下的空气作为绝缘介质的气体绝缘金属封闭开关设备;介于敞开式和GIS之间的成套开关设备也可以参考本标准。 本标准所指的GIS是由若干相互直接连接在一起的单独元件构成的,且只有在这种方式下才能运行。

Specification for Gas-insulated metal-enclosed switchgear

ICS
29.130.10
CCS
K43
发布
2010-05-24
实施
2010-10-01

This technical report applies to high-voltage air-insulated disconnectors for rated voltages above 52 kV. The report describes the capacitive current switching duty and provides guidance on laboratory testing to demonstrate the switching capability. Air-insulated disconnectors equipped with auxiliary interrupting devices are included under this scope.NOTE For manually operated disconnectors, the safety of the operator should be considered and it should be recognized that the results of the tests described herein are not necessarily representative of the performance of such disconnectors in actual service. Due diligence should be exercised if switching tests

High-voltage switchgear and controlgear - Part 305: Capacitive current switching capability of air-insulated disconnectors for rated voltages above 52 kV

ICS
29.130.10
CCS
发布
2010-05-12
实施
2010-05-12

This part of IEC 62271 mainly applies to a.c. circuit-breakers within the scope of IEC 62271- 100. It provides the general rules for testing a.c. circuit-breakers@ for making and breaking capacities over the range of test duties described in 6.102 to 6.111 of IEC 62271-100@ by synthetic methods.NOTE Circuits for the test duties described in 6.111 have not yet been standardized. However@ present methods are given in Annex G.It has been proven that synthetic testing is an economical and technically correct way to test high-voltage a.c. circuit-breakers according to the requirements of IEC 62271-100 and that it is equivalent to direct testing.The methods and techniques described are those in general use. The purpose of this standard is to establish criteria for synthetic testing and for the proper evaluation of results. Such criteria will establish the validity of the test method without imposing restraints on innovation of test circuitry.

High-voltage switchgear and controlgear - Part 101: Synthetic testing

ICS
29.130.10
CCS
K43
发布
2010-05
实施
2010-12-01

IEC/TR 62271-208:2009 gives practical guidance for the evaluation and documentation of the external electromagnetic fields which are generated by HV switchgear assemblies and HV/LV prefabricated substations. Basic requirements to measure or calculate the electric and magnetic fields are summarised for switchgear assemblies covered by IEC 62271-200 and IEC 62271-201, and for prefabricated substations covered by IEC 62271-202. This technical report applies to equipment rated for voltages up to and including 52 kV and power-frequencies from 15 Hz to 60 Hz.

High-voltage switchgear and controlgear - Part 208: Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations

ICS
29.130.10
CCS
发布
2010-04-23
实施
-

This standard is applicable to three-pole alternating current switches for rated voltages 52 kV and above, having making and breaking current ratings, for indoor and outdoor installations, and for rated frequencies up to and including 60 Hz. This standard is also applicable to the operating devices of these switches and to their auxiliary equipment.

High-voltage switchgear and controlgear - Part 104: Alternating current switches for rated voltages of 52 kV and above (IEC 62271-104:2009); German version EN 62271-104:2009

ICS
29.130.10
CCS
K43
发布
2010-03
实施
2010-03-01

Applies to high-voltage switchgear and controlgear such as circuit-breakers, disconnectors and switches.

High-voltage switchgear and controlgear Part 301: Dimensional standardisation of high-voltage terminals

ICS
29.130.10
CCS
K43
发布
2010-01-22
实施