29.140.30 荧光灯、放电灯 标准查询与下载



共找到 929 条与 荧光灯、放电灯 相关的标准,共 62

What is BS EN 60929 – Tubular fluorescent lamps about?   BS EN 60929 is an international standard that discusses the performance requirements for AC and/or DC supplied electronic control gear for tubular fluorescent lamps. A fluorescent lamp converts electrical energy into useful light much more efficiently than an incandescent lamp.   BS EN 60929 specifies performance requirements for electronic control gear for use on a.c. at 50 Hz or 60 Hz and/or d.c. supplies, both up to 1 000 V, with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901 , and other fluorescent lamps for high-frequency operation.  

AC and/or DC-supplied electronic control gear for tubular fluorescent lamps. Performance requirements

ICS
29.140.30
CCS
发布
2011-11-30
实施
2011-11-30

Amendment 5 - Single-capped fluorescent lamps - Performance specifications

ICS
29.140.30
CCS
发布
2011-11-23
实施

This International Standard specifies the safety requirements for single-capped fluorescent lamps for general lighting purposes of all groups having caps according to Table 1.It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure which can be used to make limited assessment of batches are also given in this standard.NOTE Compliance with this standard concerns only safety criteria and does not take into accou

Single-capped fluorescent lamps - Safety specifications

ICS
29.140.30
CCS
发布
2011-11-19
实施
2011-11-19

Metal halide lamps - Performance specification.

ICS
29.140.30
CCS
K71
发布
2011-11-01
实施
2011-11-26

IEC 62554:2011 specifies sample preparation methods for determining mercury levels in new tubular fluorescent lamps (including single capped, double capped, self-ballasted and CCFL for backlighting) containing 0,1 mg mercury or more. The intended resolution of the methods described in this standard is of the order of 5 %. Mercury level measurement of spent lamps is excluded, as during lamp operation, mercury gradually diffuses into the glass wall and reacts with the glass materials. The test method of this standard does not recover mercury that is diffused into or reacted with or otherwise incorporated irreversibly with the glass wall of discharge tubes. This standard does not contain information on measurement. Measurement is specified in IEC 62321.

Sample preparation for measurement of mercury level in fluorescent lamps

ICS
29.140.30
CCS
发布
2011-10-28
实施
2011-12-23 (7)

Fluorescent induction lamps - Safety specifications (IEC 62532:2011)

ICS
29.140.30
CCS
发布
2011-10-28
实施
2011-10-28

This International Standard specifies performance requirements for ballasts for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. Clauses 12 through 15 each detail specific requirements for a particular type of ballast. This standard covers inductive type ballasts for use on a.c. supplies up to 1 000 V at 50 Hz to 60 Hz associated with discharge lamps, having rated wattage, dimensions and characteristics as specified in the relevant IEC lamp standards. This consolidated version consists of the third edition (2005) and its amendment 1 (2006). Therefore, no need to order amendment in addition to this publication.

Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements

ICS
29.140.30
CCS
发布
2011-10-12
实施

This international Standard specifies performance requirements for electronic control gear for use on a.c. and/or d.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation.NOTE 1 Tests in this standard are type tests. Requirements for testing individual control gear during production are not included.NOTE 2 There are regional standards regarding the regulation of mains current harmonics and immunity for endproducts like luminaires and independent control gear. In a luminaire,

AC and/or DC-supplied electronic control gear for tubular fluorescent lamps - Performance requirements

ICS
29.140.30
CCS
发布
2011-10-08
实施
2011-10-08

Fluorescent induction lamps - Safety specifications (IEC 62532:2011); German version EN 62532:2011

ICS
29.140.30
CCS
K71
发布
2011-10
实施
2011-10-01

Single-capped fluorescent lamps. Safety specifications

ICS
29.140.30
CCS
K71
发布
2011-09-30
实施
2011-09-30

IEC 61199:2011 specifies the safety requirements for single-capped fluorescent lamps for general lighting purposes of all groups havingcaps according to Table 1. It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure which can be used to make limited assessment of batches are also given in this standard. This third edition cancels and replaces the second edition published in 1999. It constitutes a technical revision. Main technical changes are the introduction of requirements for high frequency operation, a new temperature measurement position and few new cap-holder fits.

Single-capped fluorescent lamps - Safety specifications

ICS
29.140.30
CCS
发布
2011-09-23
实施
2011-11-15 (7)

This International Standard specifies the performance requirements for metal halide lamps for general lighting purposes. For some of the requirements given in this standard, reference is made to “the relevant lamp data sheet”. For some lamps, these data sheets are contained in this standard. For other lamps, falling under the scope of this standard, the relevant data are supplied by the lamp manufacturer or responsible vendor. The requirements of this standard relate only to type testing. NOTE The requirements and tolerances permitted by this standard correspond to testing of a type test sample submitted by the manufacturer for that purpose. In principle this type test sample should consist of units having characteristics typical of the manufacturer’s production and being as close to the production centre point values as possible. It may be expected with the tolerances given in the standard that product manufactured in accordance with the type test sample will comply with the standard for the majority of production. Due to the production spread however, it is inevitable that there will sometimes be products outside the specified tolerances. For guidance on sampling plans and procedures for inspection by attributes, see IEC 60410.

Metal halide lamps. Performance specification

ICS
29.140.30
CCS
K71
发布
2011-08-31
实施
2011-08-31

Fluorescent induction lamps. Safety specifications

ICS
29.140.30
CCS
K71
发布
2011-08-31
实施
2011-08-31

This International Standard specifies the performance requirements for metal halide lamps for general lighting purposes.For some of the requirements given in this standard, reference is made to “the relevant lamp data sheet”. For some lamps, these data sheets are contained in this standard. For other lamps, falling under the scope of this standard, the relevant data are supplied by the lamp manufacturer or responsible vendor.The requirements of this standard relate only to type testing.NOTE The requirements and tolerances permitted by this standard correspond to testing of a type test sample submitted by the manufacturer for that purpose. In principle this

Metal halide lamps - Performance specification

ICS
29.140.30
CCS
发布
2011-08-05
实施
2011-08-05

This International Standard specifies sample preparation methods for determining mercury levels in new tubular fluorescent lamps (including single capped@ double capped@ self-ballasted and CCFL for backlighting) containing 0@1 mg mercury or more. The intended resolution of the methods described in this standard is of the order of 5 %. Mercury level measurement of spent lamps is excluded@ as during lamp operation@ mercury gradually diffuses into the glass wall and reacts with the glass materials. The test method of this standard does not recover mercury that is diffused into or reacted with or otherwise incorporated irreversibly with the glass wall of discharge tubes. This standard does not contain information on measurement. Measurement is specified in IEC 62321.

Sample preparation for measurement of mercury level in fluorescent lamps

ICS
29.140.30
CCS
K71
发布
2011-08
实施
2017-10-20

This International Standard specifies the safety requirements for fluorescent induction lamps for general lighting purposes.It also specifies the method a manufacturer should use to show compliance with therequirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes.Details of a batch test procedure, which can be used to make limited assessment of batches, are also given in this standard.The schematic drawings of the systems are shown in Annex A.NOTE Self-ballasted induction lamps (where the discharge vessel, the power coupler an

Fluorescent induction lamps - Safety specifications

ICS
29.140.30
CCS
发布
2011-07-31
实施
2011-07-31

This Standard specifies the germicidal lamps of which the mercury vapour pressure in a tube at the time of lighting is about 100 Pa or less.It does not apply to those ger-micidal lamps integral with an arc tube,ballast and an starting point.

Germicidal lamps

ICS
29.140.30
CCS
K71
发布
2011-07-20
实施

IEC 60929:2011 specifies performance requirements for electronic control gear for use on a.c. at 50 Hz or 60 Hz and/or d.c. supplies, both up to 1 000 V, with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. This fourth edition cancels and replaces the third edition published in 2006, IEC 60925 published in 1989, its Amendment 1 (1996) and its Amendment 2 (2001). This fourth edition constitutes a technical revision. The essential change with respect to the third edition is the extension to DC supplied control gear and the deletion of the requirements for digital signal control of electronic control gear. The contents of the corrigendum of September 2011 have been included in this copy.

AC and/or DC-supplied electronic control gear for tubular fluorescent lamps - Performance requirements

ICS
29.140.30
CCS
发布
2011-07-01
实施
2011-09-23 (7)

This International Standard specifies the safety requirements for single-capped fluorescent lamps for general lighting purposes of all groups having caps according to Table 1. It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure which can be used to make limited assessment of batches are also given in this standard. NOTE Compliance with this standard concerns only safety criteria and does not take into account the performance of single-capped fluorescent lamps for general lighting purposes with respect to luminous flux@ colour@ starting and operational characteristics. For this information@ readers are referred to IEC 60901. It may be expected that lamps which comply with this standard will operate safely at supply voltages between 90 % and 110 % of rated supply voltage of the used ballast and when operated with a ballast complying with IEC 61347-2-3 or IEC 61347-2-8 with a starting device complying with IEC 60155 (if applicable) and in a luminaire complying with IEC 60598-1.

Single-capped fluorescent lamps - Safety specifications

ICS
29.140.30
CCS
K71
发布
2011-07
实施
2011-07-13

IEC 62532:2011 specifies the safety requirements for fluorescent induction lamps for general lighting purposes. It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure, which can be used to make limited assessment of batches, are also given in this standard.

Fluorescent induction lamps - Safety specifications

ICS
29.140.30
CCS
发布
2011-05-13
实施
2011-06-07 (7)