29.140.40 照明设备 标准查询与下载



共找到 1152 条与 照明设备 相关的标准,共 77

Fixed general purpose luminaires

ICS
29.140.40
CCS
发布
2014-11-10
实施

"This part of IEC 60598 specifies requirements for lighting chains fitted with series@ parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. For combinations where rope lights (also known as sealed lighting chains) are included@ see IEC 60598-2-21. Lighting chains provided with fixed or detachable attachments e.g. ornamental or decorative@ are considered to be covered by this standard. For lighting chains fitted with lampholders of the push-in type@ the appropriate requirements of this standard applies. NOTE 1 A Christmas tree lighting chain is an example of a lighting chain fitted with series or series/parallel connected lamps. A chain for illuminating ski-tracks or promenades is an example of a lighting chain fitted with parallel connected lamps. For lighting chains with non-standardised lamps (e.g. lamps of the push-in type) the lamps are regarded as a part of the lighting chain and consequently included in the testing. NOTE 2 For products where the lighting chain is permanently fixed to a frame or pre-lit Christmas tree the relevant clauses of IEC 60598-2-4 and/or IEC 60598-2-7 can also apply. NOTE 3 In some countries the term ""strings"" is used instead of ""chains"". NOTE 4 Candlestick luminaries are tested according to IEC 60598-2-4."

Luminaires - Part 2-20: Particular requirements - Lighting chains

ICS
29.140.40
CCS
K74
发布
2014-11
实施
2014-12-03

This part of IEC 62722 specifies the performance requirements for LED luminaires@ together with the test methods and conditions@ required to show compliance with this standard. It applies to LED luminaires for general lighting purposes. The following types of LED luminaires are distinguished. ?C Type A ?C Luminaires using LED modules where compliance with IEC 627171 has been proven. ?C Type B ?C Luminaires using LED modules where compliance with IEC 627171 has not been proven. ?C Type C ?C Luminaires using a LED lamp and covered in IEC 62722-1. The requirements of this standard only relate to type testing. This standard does not cover Type C luminaires. This standard does not cover LED luminaires that intentionally produce coloured light@ neither does it cover luminaires using OLEDs (organic LEDs). These performance requirements are additional to the requirements in IEC 62722-1@ Clauses 1 to 9@ except where in this Part 2-1 alternative methods of measurement or limits are specified. As this standard has been simultaneously developed and edited with the standard for LED modules@ where appropriate the compliance of the LED modules to the provisions of IEC 62717 may be transferred to the whole luminaire. Life time of LED luminaires is in most cases much longer than the practical test times. Consequently@ verification of manufacturer's life time claims cannot be made in a sufficiently confident way. For that reason the acceptance or rejection of a manufacturer's life time claim@ past 25 % of rated life (with a maximum of 6 000 h)@ is out of the scope of this standard. Instead of life time validation@ this standard has opted for lumen maintenance categories at a defined finite test time. Therefore@ the category number does not imply a prediction of achievable life time. The categories are lumen-depreciation character categories showing behaviour in agreement with manufacturer's information which is provided before the test is started. In order to validate a life time claim@ an extrapolation of test data is needed. A general method of projecting measurement data beyond limited test time is under consideration. For explanation of recommended life time metrics see IEC 62717@ Annex C. It may be expected that LED luminaires which comply with this standard will start and operate satisfactorily at voltages between 92 % and 106 % of rated supply voltage and at an ambient air temperature within the declared range of the manufacturer. Evaluation of LOR (light output ratio) for LED luminaire is under consideration. 1 To be published.

Luminaire performance - Part 2-1: Particular requirements for LED luminaires

ICS
29.140.40
CCS
K73
发布
2014-11
实施
2014-12-03

"This part of IEC 60598 specifies requirements for rope lights (sealed lighting chains) fitted with non-replaceable series- or parallel- or a combination of series/parallel-connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. NOTE 1 In some countries the term ""sealed lighting chain"" is used instead of ""rope light"". NOTE 2 For products where the rope light is fixed to a frame or the like as ornaments like Santa Claus@ snowman and similar@ relevant clauses of IEC 60598-2-4 and/or IEC 60598-2-7 can also apply. Rope lights provided with@ fixed or detachable@ extra attachments of different kinds@ e.g. ornamental element in temporary decorative configurations due to festivals@ celebrations@ etc. or in two or three dimensional reproductions of persons or animals (real or imaginary) are considered to be covered by this standard."

Luminaires - Part 2-: 21: Particular requirements - Rope lights

ICS
29.140.40
CCS
发布
2014-11
实施
2014-12-03

Luminaires. Particular requirements. Luminaires for emergency lighting

ICS
29.140.40
CCS
K71
发布
2014-10-31
实施
2014-10-31

Luminaire performance - Part 1: General requirements

ICS
29.140.40
CCS
K73
发布
2014-09-01
实施

本标准规定了工作于13.56 MHz频率的非接触式识别卡读写机的术语和定义、技术要求、试验方法和检验规则,以及标志、包装、运输、贮存和使用说明书的要求。 本标准适用于工作频率为13.56 MHz的手持式、台式、内置或外置等工作模式的非接触式识别卡读写机,包括读写功能或者仅有读功能的读写机(以下统称“读写机”或“产品”)。

General specification for non-contact identification card reader

ICS
29.140.40
CCS
X55
发布
2014-08-27
实施
2014-12-01

本标准主要对LED户外照明系统防雷工程的设计和施工作出规定和要求。适用于新建及 改建LED照明路灯、隧道灯、庭院灯、投光灯等户外型LED照明系统工程的防雷设计及施工。

Technical requirements of lightning protection for outdoor LED lighting

ICS
29.140.40
CCS
C3872
发布
2014-08-15
实施
2017-07-24

"This Part 1 of IEC 60598 specifies general requirements for luminaires@ incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover: classification@ marking@ mechanical construction@ electrical construction and photobiological safety. Each section of this Part 1 is read in conjunction with this Section 0 and with other relevant sections to which reference is made. Each part of IEC 60598-2 details requirements for a particular type of luminaire or group of luminaires on supply voltages not exceeding 1 000 V. These parts are published separately for ease of revision and additional sections will be added as and when a need for them is recognized. The presentation of photometric data for luminaires is under consideration by the International Commission on Illumination (CIE) and is not@ therefore@ included in this Part 1. Requirements for semi-luminaires are included in this Part 1. In general@ this Part 1 covers safety requirements for luminaires. The object of this Part 1 is to provide a set of requirements and tests which are considered to be generally applicable to most types of luminaires and which can be called up as required by the detail specifications of IEC 60598-2. This Part 1 is thus not regarded as a specification in itself for any type of luminaire@ and its provisions apply only to particular types of luminaires to the extent determined by the appropriate part of IEC 60598-2. The parts of IEC 60598-2@ in making reference to any of the sections of Part 1@ specify the extent to which that section is applicable and the order in which the tests are to be performed; they also include additional requirements as necessary. The order in which the sections of Part 1 are numbered has no particular significance as the order in which their provisions apply is determined for each type of luminaire or group of luminaires by the appropriate part of IEC 60598-2. All parts of IEC 60598-2 are self-contained and therefore do not contain references to other parts of IEC 60598-2. Where the requirements of any of the sections of Part 1 are referred to in the parts of IEC 60598-2 by the phrase ""The requirements of section... of IEC 60598-1 apply""@ this phrase is to be interpreted as meaning that all the requirements of that section of Part 1 apply except those which are clearly inapplicable to the particular type of luminaire covered by that part of IEC 60598-2. For explosion proof luminaires@ as covered by IEC 60079@ the requirements of IEC 60598 (selecting the appropriate parts 2) are applied in addition to the requirements of IEC 60079. In the event of any conflict between IEC 60598 and IEC 60079@ the requirements of IEC 60079 take priority. Attention is drawn to lamp performance standards which contain ""information for luminaire design""; this should be followed for proper lamp operation; however@ this standard does not require the testing of lamp performance as part of the type test approval for luminaires. Improvements in safety to take into account the state of the art technology are incorporated in the standards with revisions and amendments on an ongoing basis. Regional standardisation bodies may include statements in their derived standards to cover products which have complied with the previous document as shown by the manufacturer or standardization body. The statements may require that for such products@ the previous standard may continue to apply to production until a defined date after which the new standard shall apply."

Luminaires - Part 1: General requirements and tests

ICS
29.140.40
CCS
K72
发布
2014-05-01
实施
2017-09-19

本标准规定了LED医用X线胶片观察灯的术语和定义,产品分类,技术要求,试验方法,检验规则,标志、产品使用说明书,包装、运输、贮存。 本标准适用于以LED为光源的医用X线胶片观察灯,供医院、诊所、科研单位等部门观察X线胶片用。

LED medical X-ray film observation lamp

ICS
29.140.40
CCS
K73
发布
2014-04-18
实施
2014-07-18

标准规定了以LED为光源、电源电压不超过250V的一般照明用可移式灯具的术语和定义、测试环境和测试方法等技术要求。 本标准不适用于手提灯和带有应急转换功能的可移式LED灯具。

Portable LED lamps

ICS
29.140.40
CCS
K72
发布
2014-04-18
实施
2014-07-18

本标准规定了LED射灯的分类和分档、要求、试验方法、检验规则及标志、包装、运输、贮存。 本标准适用于室内照明作为普通照明、局部照明或定位照明用的LED射灯。 适用范围如下: ——额定功率60W以下; ——额定电压AC220V频率50Hz、DC120V及以下。

LED spotlight

ICS
29.140.40
CCS
K71
发布
2014-04-18
实施
2014-07-18

本规范规定了以LED为光源、电源电压不超过250V的室内一般照明用LED平板灯的分类、性能要求、安全要求、能效要求、试验条件与方法、检验规则、标志、包装、运输和贮存。

LED panel light

ICS
29.140.40
CCS
K71
发布
2014-04-18
实施
2014-07-18

本标准规定了充电式LED手电筒的术语和定义、分类、一般要求、一般试验要求、特殊技术要求、试验方法、标记、包装、运输和贮存。 本标准适用于以LED为光源,利用内置或外置的额定输入电压为220V交流,输出为安全特低电压的充电装置,或通过其他电子设备的直流安全特低电压输出接口,向内部的蓄电池进行反复充电的手电筒。 本标准不适用于警用强光手电筒、防爆手电筒、水下手电筒等特殊用途的手电筒。

Rechargeable LED Flashlight

ICS
29.140.40
CCS
K71
发布
2014-04-18
实施
2014-07-18

Luminaires - Part 2-24: Particular requirements - Luminaires with limited surface temperatures (IEC 60598-2-24:2013); German version EN 60598-2-24:2013

ICS
29.140.40
CCS
K72
发布
2014-04
实施
2014-04-01

Luminaires - Part 2-11: Particular requirements - Aquarium luminaires (IEC 60598-2-11:2013); German version EN 60598-2-11:2013

ICS
29.140.40
CCS
K72
发布
2014-04
实施
2014-04-01

Luminaires -- Part 5: Gonio-photometric methods (Amendment 1)

ICS
29.140.40
CCS
K72
发布
2014-03-20
实施

Luminaires - Part 2-8: Particular requirements - Handlamps (IEC 60598-2-8:2013); German version EN 60598-2-8:2013

ICS
29.140.40
CCS
K72
发布
2014-03
实施
2014-03-01

Luminaires - Part 2-12: Particular requirements - Mains socket-outlet mounted nightlights (IEC 60598-2-12:2013); German version EN 60598-2-12:2013

ICS
29.140.40
CCS
K72
发布
2014-03
实施
2014-03-01

Sharp edge testing apparatus and test procedure for lighting equipment. Tests for sharpness of edge

ICS
29.140.40
CCS
K72
发布
2014-02-28
实施
2014-02-28



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved