29.260.20 易爆环境用电气设备 标准查询与下载



共找到 1719 条与 易爆环境用电气设备 相关的标准,共 115

本标准规定了矿用隔爆兼本安型声光语言报警装置主机的产品分类、技术要求、试验方法、检验规 则、标志、包装、运输及贮存。 本标准适用于矿用隔爆兼本安型声光语言报警装置主机(以下简称主机)。 注:该矿用隔爆兼本安型声光语言报警装置主机主要用于煤矿井下车场及机电峒室、中心变电所、大巷运输、泵房 等场所。并向各配接传感器等提供所需直流电源,接收传感器信号后发出语音及文字报警

Mining explosion-proof and intrinsically safe sound and light language alarm device host

ICS
29.260.20
CCS
K34
发布
2017-06-30
实施
2017-07-30

Technical specification for electrical explosion-proof safety testing in hazardous locations

ICS
29.260.20
CCS
K 35
发布
2017-05-17
实施
2017-08-01

The requirements of the IEC 60079 series of Standards cover protection with respect to explosion hazard only. The CAN/CSA-C22.2 No. 60079 series of Standards (based on the adoption of the corresponding IEC Standards) is to be used in conjunction with other applicable Standards containing the appropriate electrical safety requirements for general use equipment.

Explosive atmospheres — Part 30-1: Electrical resistance trace heating — General and testing requirements

ICS
29.260.20
CCS
发布
2017-05-01
实施

The requirements of the IEC 60079 series of Standards cover protection techniques with respect to explosion hazard only. The CAN/CSA-C22.2 No. 60079 series of Standards (based on the adoption of corresponding IEC Standards) is to be used in conjunction with other applicable Standards containing the appropriate electrical safety requirements for general use equipment. Group I electrical equipment intended for use in mines susceptible to firedamp is regulated by the provinces and territories of Canada. Such types of equipment (e.g., caplights) should be referred to the respective authority having jurisdiction.

Explosive atmospheres — Part 29-1: Gas detectors — Performance requirements of detectors for flammable gases

ICS
29.260.20
CCS
发布
2017-05-01
实施

Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"

ICS
29.260.20
CCS
K35
发布
2017-05
实施

The requirements of the IEC 60079 series of Standards cover protection with respect to explosion hazard only. The CAN/CSA-C22.2 No. 60079 series of Standards (based on the adoption of corresponding IEC Standards) is to be used in conjunction with other applicable Standards containing the appropriate electrical safety requirements for general use equipment. Group I electrical equipment intended for use in mines susceptible to firedamp is regulated by the provinces and territories of Canada. Such types of equipment (e.g., caplights) should be referred to the respective authority having jurisdiction.

Explosive atmospheres — Part 6: Equipment protection by liquid immersion “o”

ICS
29.260.20
CCS
发布
2017-04-01
实施

Explosive atmospheres - Part 30-1: Electrical resistance trace heating - General and testing requirements

ICS
29.260.20
CCS
发布
2017-04-01
实施

Explosive atmospheres - Part 32-1: Electrostatic hazards, guidance

ICS
29.260.20
CCS
发布
2017-03-16
实施

Explosive atmospheres - Part 20-2: Material characteristics - Combustible dusts test methods; Technical Corrigendum 1

ICS
29.260.20
CCS
C67
发布
2017-03
实施

Explosive atmospheres - Part 32-1: Electrostatic hazards, guidance

ICS
29.260.20
CCS
K35
发布
2017-03
实施

The motor has not been type-tested for this duty as a unit in association with the converter. In this case, means (or equipment) for direct temperature control by embedded temperature sensors specified in the motor documentation or other effective measures for limiting the surface temperature of the motor housing shall be provided. The effectiveness of the temperature control shall take into consideration power, speed range, torque and frequency for the duty required and shall be verified and documented. The action of the protective device shall cause the motor to be electrically disconnected.

Explosive Atmospheres - Part 14: Electrical installations design, selection and erection; Interpretation Sheet 1

ICS
29.260.20
CCS
K35
发布
2017-02
实施

Explosion-proof metal works. General technical requirements and test methods

ICS
29.260.20
CCS
发布
2017
实施
2018-01-01

Explosion-proof dehumidifier

ICS
29.260.20
CCS
K 35
发布
2016-12-29
实施
2017-03-29

Explosion-proof unit air conditioner

ICS
29.260.20
CCS
K 35
发布
2016-12-29
实施
2017-03-29

IEC 60079-10-2:2015 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way to compare all the changes between this standard and its previous edition. The Redline version is not an official IEC Standard, only the current version of the standard is to be considered the official document. IEC 60079-10-2:2015 is concerned with the identification and classification of areas where explosive dust atmospheres and combustible dust layers are present, in order to permit the proper assessment of ignition sources in such areas. In this standard, explosive dust atmospheres and combustible dust layers are treated separately. In Clause 4, area classification for explosive dusts clouds is described, with dust layers acting as one of the possible sources of release. In Clause 7 other general considerations for dust layers are described. The examples in this standard are based on a system of effective housekeeping being implemented in the plant to prevent dust layers from accumulating. Where effective housekeeping is not present, the area classification includes the possible formation of explosive dust clouds from dust layers. The principles of this standard can also be followed when combustible fibres or flyings might cause a hazard. This standard is intended to be applied where there can be a risk due to the presence of explosive dust atmospheres or combustible dust layers under normal atmospheric conditions. Please refer to the foreword of the document for a detailed listing of the significant technical changes from the previous edition. Keywords: explosive dust atmospheres, combustible dust layers, ignition hazard Look inside

Explosive atmospheres – Part 10-2: Classification of areas – Explosive dust atmospheres

ICS
29.260.20
CCS
发布
2016-12-22
实施

IEC 60079-28:2015 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way to compare all the changes between this standard and its previous edition. The Redline version is not an official IEC Standard, only the current version of the standard is to be considered the official document. IEC 60079-28:2015 specifies the requirements, testing and marking of equipment emitting optical radiation intended for use in explosive atmospheres. It also covers equipment located outside the explosive atmosphere or protected by a Type of Protection listed in IEC 60079-0, but which generates optical radiation that is intended to enter an explosive atmosphere. It covers Groups I, II and III, and EPLs Ga, Gb, Gc, Da, Db, Dc, Ma and Mb. This standard does not cover ignition by ultraviolet radiation and by absorption of the radiation in the explosive mixture itself. Explosive absorbers or absorbers that contain their own oxidizer as well as catalytic absorbers are also outside the scope of this standard. This second edition cancels and replaces the first edition, published in 2006, and constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes between edition 2.0 and previous edition of the document. Keywords: equipment emitting optical radiation intended for use in explosive atmospheres

Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation

ICS
29.260.20
CCS
发布
2016-12-22
实施

This part of IEC 60079 specifies the requirements, testing and marking of equipment emitting optical radiation intended for use in explosive atmospheres. It also covers equipment located outside the explosive atmosphere or protected by a Type of Protection listed in IEC 60079-0, but which generates optical radiation that is intended to enter an explosive atmosphere. It covers Groups I, II and III, and EPLs Ga, Gb, Gc, Da, Db, Dc, Ma and Mb. This standard contains requirements for optical radiation in the wavelength range from 380 nm to 10 µm. It covers the following ignition mechanisms: • Optical radiation is absorbed by surfaces or particles, causing them to heat up, and under certain circumstances this may allow them to attain a temperature which will ignite a surrounding explosive atmosphere. • In rare special cases, direct laser induced breakdown of the gas at the focus of a strong beam, producing plasma and a shock wave both eventually acting as ignition source. These processes can be supported by a solid material close to the breakdown point. NOTE 1 See a) and d) of the introduction. This standard does not cover ignition by ultraviolet radiation and by absorption of the radiation in the explosive mixture itself. Explosive absorbers or absorbers that contain their own oxidizer as well as catalytic absorbers are also outside the scope of this standard. This standard specifies requirements for equipment intended for use under atmospheric conditions. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This standard applies to optical fibre equipment and optical equipment, including LED and laser equipment, with the exception of the equipment detailed below: 1) Non-array divergent LEDs used for example to show equipment status or backlight function. 2) All luminaires (fixed, portable or transportable), hand lights and caplights; intended to be supplied by mains (with or without galvanic isolation) or powered by batteries: – with continuous divergent light sources (for all EPLs), – with LED light sources (for EPL Gc or Dc only). NOTE 2 Continuous divergent LED light sources for other than EPL Gc or Dc are not excluded from the standard due to the uncertainty of potential ignition concerns regarding high irradiance. 3) Optical radiation sources for EPL Mb, Gb or Gc and Db or Dc applications which comply with Class 1 limits in accordance with IEC 60825-1. NOTE 3 The referenced Class 1 limits are those that involve emission limits below 15 mW measured at a distance from the optical radiation source in accordance with IEC 60825-1, with this measured distance reflected in the Ex application. 4) Single or multiple optical fibre cables not part of optical fibre equipment if the cables: – comply with the relevant industrial standards, along with additional protective means, e.g. robust cabling, conduit or raceway (for EPL Gb, Db, Mb, Gc or Dc), – comply with the relevant industrial standards (for EPL Gc or Dc). 5) Enclosed equipment involving an enclosure that fully contains the optical radiation and that complies with a suitable type of protection as required by the involved EPL, with the enclosure complying with one of the following conditions: – An enclosure for which an ignition due to optical radiation in combination with absorbers inside the enclosure would be acceptable such as flameproof "d" enclosures (IEC 60079-1), or – An enclosure for which protection regarding ingress of an explosive gas atmosphere is provided, such as pressurized "p" enclosures (IEC 60079-2), restricted breathing “nR” enclosure (IEC 60079-15), or – An enclosure for which protection regarding ingress of an explosive dust atmosphere is provided, such as dust protection "t" enclosures" (IEC 60079-31), or – An enclosure for which protection regarding ingress of absorbers is provided (such as IP 6X enclosures) and where no internal absorbers are to be expected. NOTE 4 For these scope exclusions based on enclosure constructions, it is anticipated that the enclosures are not opened in the explosive atmosphere, so that ingress is protected.

Explosive atmospheres — Part 28: Protection of equipment and transmission systems using optical radiation

ICS
29.260.20
CCS
发布
2016-12-01
实施

Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases

ICS
29.260.20
CCS
发布
2016-12-01
实施

Explosive atmospheres - Part 38: Equipment and components in explosive atmospheres in underground mines (ISO/IEC 80079-38:2016)

ICS
29.260.20
CCS
K35
发布
2016-12
实施

Technical conditions of YZYKS, YZYKS-W series high-voltage positive pressure three-phase asynchronous motors (frame number 710~1120)

ICS
29.260.20
CCS
K25
发布
2016-10-22
实施
2017-04-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved