29.260.20 易爆环境用电气设备 标准查询与下载



共找到 1719 条与 易爆环境用电气设备 相关的标准,共 115

Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases

ICS
29.260.20
CCS
N56
发布
2016-07
实施

The requirements of the IEC 60079 series of Standards cover protection with respect to explosion hazard only. The CAN/CSA-C22.2 No. 60079 series of Standards (based on the adoption of corresponding IEC Standards) is to be used in conjunction with other applicable Standards containing the appropriate electrical safety requirements for general use equipment. Les exigences des normes de la série IEC 60079 portent sur la protection en ce qui a trait au risque d’explosion uniquement. Les normes de la série CAN/CSA-C22.2 nº 60079 (basées sur l’adoption des normes IEC correspondantes) doivent être utilisées avec d’autres normes pertinentes qui énoncent les exigences en matière de sécurité électrique applicables au matériel d’usage général.

Explosive atmospheres — Part 15: Equipment protection by type of protection “n”

ICS
29.260.20
CCS
发布
2016-06-01
实施

Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" (IEC 60079-6:2015); German version EN 60079-6:2015

ICS
29.260.20
CCS
K35
发布
2016-06
实施

Explosive atmospheres - Part 7 : equipment protection by increased safety "e"

ICS
29.260.20
CCS
K35
发布
2016-04-02
实施
2016-04-02

Dieser Teil von ISO/IEC 80079 legt die grundlegende Verfahrensweise für und Anforderungen an Konstruktion, Bau, Prüfung und Kennzeichnung von nicht-elektrischen Ex-Geräten, Ex-Bauteilen, Schutzsystemen, Geräten und Baugruppen dieser Produkte fest, die eigene potentielle Zündquellen aufweisen und für den Einsatz in explosionsfähigen Atmosphären vorgesehen sind. Handwerkzeuge und handbetätigte Geräte ohne Energiespeicherung sind vom Anwendungsbereich dieser Norm ausgeschlossen. Diese Norm befasst sich nicht mit der Sicherheit von statischen autonomen Prozessanlagen, wenn sie kein Teil von Geräten sind, auf die in der vorliegenden Norm verwiesen wird. ANMERKUNG 1 Zu statischen autonomen Prozessanlagen gehören zum Beispiel Tanks, Behälter, fest installierte Rohrleitungen und handbetätigte Ventile ohne eigene Energiequelle, die im laufenden Betrieb eine potentielle Zündquelle entstehen lassen könnten. Diese Norm legt keine Anforderungen an die Sicherheit fest, außer wenn sie sich direkt auf das Zündrisiko beziehen, das dann zu einer Explosion führen könnte. Die üblichen atmosphärischen Bedingungen (in Bezug auf die Explosionskenngrößen der Atmosphäre), unter denen davon ausgegangen werden kann, dass Anlagen betrieben werden können, sind:- Temperaturbereich -20 °C bis +60 °C; - Druck 80 kPa (0,8 bar) bis 110 kPa (1,1 bar); und; - Luft mit üblichem Sauerstoffgehalt, gewöhnlich 21 % (v/v). Derartige Atmosphären können auch im Innern des Geräts vorhanden sein. Zudem kann die externe Atmosphäre durch natürlichen Austausch als Folge von Schwankungen des Betriebsdrucks im Innern des Geräts und/oder der Temperatur in das Gerät eingesaugt werden. ANMERKUNG 2 Obwohl die obenstehend aufgeführten üblichen atmosphärischen Bedingungen einen Temperaturbereich für die Atmosphäre von -20 °C bis +60 °C angeben, liegt der übliche Umgebungstemperaturbereich für das Gerät bei -20 °C bis +40 °C, sofern nichts anderes festgelegt und gekennzeichnet ist. Es wird davon ausgegangen, dass -20 °C bis +40 °C für die meisten Geräte angemessen ist; eine Fertigung aller Ex-Geräte für eine Eignung in üblicher Atmosphäre im oberen Temperaturbereich von +60 °C würde zu unnötigen Konstruktionsbeschränkungen führen. ANMERKUNG 3 Die Anforderungen der vorliegenden Norm können auch für Konstruktion, Bau, Prüfung und Kennzeichnung von Geräten von Nutzen sein, die für den Einsatz in Atmosphären außerhalb des oben festgelegten Geltungsbereichs der vorliegenden Norm vorgesehen sind. In diesem Fall müssten jedoch die Zündgefahrenbewertung, die vorgesehene Zündschutzart, zusätzliche Prüfungen (falls erforderlich), die technische Dokumentation des Herstellers und Anweisungen für den Benutzer eindeutig die Eignung des Geräts für die anzutreffenden Bedingungen nachweisen.

Explosive atmospheres - Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements

ICS
29.260.20
CCS
K35
发布
2016-04
实施

Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation (IEC 60079-28:2015); German version EN 60079-28:2015

ICS
29.260.20
CCS
K35
发布
2016-04
实施

Method for determining minimum ignition energy of dust/air mixtures

ICS
29.260.20
CCS
发布
2016-03-22
实施

This part of ISO/IEC 80079 specifies the requirements for the design and construction of non- electrical equipment, intended for use in explosive atmospheres, protected by the types of protection constructional safety “c”, control of ignition source “b” and liquid immersion “k”. This part of ISO/IEC 80079 supplements and modifies the requirements in ISO 80079-36. Where a requirement of this standard conflicts with the requirement of ISO 80079-36 the requirement of this standard takes precedence. Types of Protection “c”, “k” and “b” are not applicable for Group I, EPL Ma without additional protective precautions. The types of ignition protection described in the standard can be used either on their own or in combination with each other to meet the requirements for equipment of Group I, Group II, and Group III depending on the ignition hazard assessment in ISO 80079-36.

Explosive atmospheres — Part 37: Non-electrical equipment for explosive atmospheres — Non-electrical type of protection constructional safety ''c'', control of ignition sources ''b'', liquid immersion

ICS
29.260.20
CCS
发布
2016-03-09
实施

Explosive atmospheres — Part 36: Non-electrical equipment for explosive atmospheres — Basic method and requirements

ICS
29.260.20
CCS
发布
2016-03-09
实施

为引导我国爆炸性环境用LED防爆照明应用的健康快速发展,规范产品技术要求,真正体现LED照明产品的节能减排效果,特制定《爆炸性气体环境用LED防爆灯 性能要求》标准。 本标准规定了LED防爆灯的术语和定义、分类与命名、技术要求、试验方法、标志、使用说明、包装、储存、运输和检验规则。

LED Explosion Proof Luminaires Apparatus for Explosive Gas Atmospheres- Performance Specifications

ICS
29.260.20
CCS
C3872
发布
2016-03-02
实施
2016-12-10

Dieser Teil von ISO/IEC 80079 beschreibt die Prüfverfahren für die Identifizierung von brennbarem Staub und Ablagerungen brennbarer Stäube, um die Klassifizierung von Bereichen, in denen solche Stoffe vorkommen, zum Zweck der Auswahl und Montage von elektrischen und mechanischen Ausrüstungen, die für die Verwendung in Gegenwart von brennbarem Staub geeignet sind, zu ermöglichen. Die atmosphärischen Normzustände zur Bestimmung der Eigenschaften von brennbaren Stäuben sind: Temperatur -20 °C bis +60 °C; Druck 80 kPa (0,8 bar) bis 110 kPa (1,1 bar) und; Luft mit normalem Sauerstoffgehalt, typischerweise 21 % v/v. Die definierten Prüfverfahren sind nicht anwendbar auf: anerkannte Sprengstoffe, Treibstoffe (z. B. Schießpulver, Dynamit) oder auf Stoffe und Stoffgemische, die sich unter Umständen ähnlich verhalten können oder; Stäube von Sprengstoffen und Treibstoffen, die keinen atmosphärischen Sauerstoff zur Verbrennung benötigen oder auf pyrophore Stoffe.

Explosive atmospheres - Part 20-2: Material characteristics - Combustible dusts test methods

ICS
29.260.20
CCS
K35
发布
2016-03
实施

Explosive atmospheres - Part 38: Equipment and components in explosive atmospheres in underground mines

ICS
29.260.20
CCS
发布
2016-02-18
实施

Explosive atmospheres - Part 6 : equipment protection by liquid immersion "o"

ICS
29.260.20
CCS
K35
发布
2016-02-13
实施
2016-02-13

本标准规定了YBX3系列高效率隔爆型三相异步电动机的型式、基本参数与尺寸、技术要求、试验方法、检验规则、标志、包装及保用期。 本标准适用于YBX3系列高效率隔爆型三相异步电动机(机座号63~355)(以下简称电动机)。凡属本系列电动机派生的其他要求的电动机也可参照本标准执行。

YBX3 series flameproof three-phase asynchronous motor.Specification (frame size 63 to 355)

ICS
29.260.20
CCS
K25
发布
2016-01-15
实施
2016-06-01

Explosive atmospheres - Part 14: Electrical installations design, selection and erection; Corrigendum 1

ICS
29.260.20
CCS
K35
发布
2016-01
实施
2016-01-30

Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p" (IEC 60079-2:2014); German version EN 60079-2:2014, Corrigendum to DIN EN 60079-2 (VDE 0170-3):2015-05; (IEC-Cor.:2015 to IEC 60079-2:2014)

ICS
29.260.20
CCS
K35
发布
2016-01
实施

Explosive atmospheres. Part 32-2. Electrostatics hazards. Tests

ICS
29.260.20
CCS
发布
2016-00-00
实施
2018-01-01

Explosive atmospheres. Part 18. Equipment protection by encapsulation "m"

ICS
29.260.20
CCS
发布
2016-00-00
实施
2018-01-01

Explosive atmospheres. Part 26. Equipment with equipment protection level (EPL) Ga

ICS
29.260.20
CCS
发布
2016-00-00
实施
2018-01-01

Mining equipment. Multipurpose safety systems and automated control systems for technological processes in the mine. Requirements to information support

ICS
29.260.20
CCS
发布
2016
实施
2017-08-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved