33.100.01 电磁兼容性综合 标准查询与下载



共找到 698 条与 电磁兼容性综合 相关的标准,共 47

Ground-based VHF hand-held, mobile and fixed radio transmitters, receivers and transceivers for the VHF aeronautical mobile service using amplitude modulation; Part 2: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive

ICS
33.100.01
CCS
发布
2010-05-31
实施
2010-05-31

This part of CISPR 16 specifies the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition, requirements are provided for specialized equipment for discontinuous disturbance measurements.NOTE In accordance with IEC Guide 107, CISPR 16-1-1 is a basic EMC standard for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular EMC tests for specific products.The sp

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus

ICS
33.100.01
CCS
发布
2010-05-25
实施
2010-05-25

This Technical Report addresses exposure evaluation techniques for the overall exposure level caused by the simultaneous exposure to multiple narrowband EM sources. Throughout the Report, it is assumed that the exposure evaluation occurs under static conditions, i.e., the source position and transmit-mode characteristics (e.g. emitted power, modulation scheme, etc.) of the device(s) under test do not vary significantly over the time required to carry out the evaluation using the chosen evaluation technique (e.g., field measurements). The vast majority of wireless communication systems world wide employ signalling schemes featuring narrowband waveforms, here

Guidance for evaluating exposure from multiple electromagnetic sources

ICS
33.100.01
CCS
发布
2010-05-12
实施
2010-05-12

Electromagnetic compatibility (EMC) - Part 3-13: Limits - Assessment of emission limits for the connection of unballanced installations to MV, HV and EHV power systems

ICS
33.100.01
CCS
L06
发布
2010-04
实施

Electromagnetic compatibility (EMC). Limits. Limitation of voltage fluctuations and flicker in low-voltage power supply systems for equipment with rated current greater than 75 A

ICS
33.100.01
CCS
发布
2010-02-28
实施
2010-02-28

Electromagnetic compatibility (EMC) - Limits - Limitation of voltage fluctuations and flicker in low-voltage power supply systems for equipment with rated current greater than 75 A

ICS
33.100.01
CCS
L06
发布
2010-02-28
实施
2010-02-28

This part of CISPR 18, which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception. The scope of this publication includes the causes, measurement and effects of radio interference, design aspects in relation to this interference, methods and examples for establishing limits and prediction of tolerable levels of interference from high voltage overhead power lines and associated equipment, to the reception of radio broadcast services. The frequency range covered is 0,15 MHz to 300 MHz. Radio frequency interference caused by the pantograph of overhead railway traction systems is not considered in this technical report.

Radio interference characteristics of overhead power lines and high-voltage equipment - Part 1: Description of phenomena

ICS
33.100.01
CCS
L06
发布
2010-01-01
实施
2010-06-01

This part of CISPR 18, which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception. The frequency range covered is 0,15 MHz to 300 MHz. A general procedure for establishing the limits of the radio noise field from the power lines and equipment is recommended, together with typical values as examples, and methods of measurement. The clause on limits concentrates on the low frequency and medium frequency bands and it is only in these bands where ample evidence, based on established practice, is available. No examples of limits to protect radio reception in the frequency band 30 MHz to 300 MHz have been given, as measuring methods and certain other aspects of the problems in this band have not yet been fully resolved. Site measurements and service experience have shown that levels of noise from power lines at frequencies higher than 300 MHz are so low that interference is unlikely to be caused to television reception. The values of limits given as examples are calculated to provide a reasonable degree of protection to the reception of broadcasting at the boundary of the recognized service areas of the appropriate transmitters in the radio frequency bands used for a.m. broadcasting, in the least favourable conditions likely to be generally encountered. These limits are intended to provide guidance at the planning stage of the line and national standards or other specifications against which the performance of the line may be checked after construction and during its useful life. The measuring apparatus and methods used for checking compliance with limits should comply with the respective CISPR specifications, as e.g. the basic standards series CISPR 16, see [1]*. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050-161, International Electrotechnical Vocabulary (IEV) – Chapter 161: Electromagnetic compatibility IEC 60060-2, High-voltage test techniques – Part 2: Measuring systems

Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits

ICS
33.100.01
CCS
L06
发布
2010-01-01
实施
2010-06-01

This part of CISPR 18, which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception, excluding the fields from power line carrier signals. The frequency range covered is 0,15 MHz to 300 MHz.

Radio interference characteristics of overhead power lines and high-voltage equipment - Part 3: Code of practice for minimizing the generation of radio noise

ICS
33.100.01
CCS
L06
发布
2010-01-01
实施
2010-06-01

This part of CISPR 18, which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception, excluding the fields from power line carrier signals. The frequency range covered is 0,15 MHz to 300 MHz.

Radio interference characteristics of overhead power lines and high-voltage equipment – Part 3: Code of practice for minimizing the generation of radio noise TR

ICS
33.100.01
CCS
L06
发布
2010-01-01
实施
2010-06-01

This part of CISPR 18, which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception. The frequency range covered is 0,15 MHz to 300 MHz. A general procedure for establishing the limits of the radio noise field from the power lines and equipment is recommended, together with typical values as examples, and methods of measurement. The clause on limits concentrates on the low frequency and medium frequency bands and it is only in these bands where ample evidence, based on established practice, is available. No examples of limits to protect radio reception in the frequency band 30 MHz to 300 MHz have been given, as measuring methods and certain other aspects of the problems in this band have not yet been fully resolved. Site measurements and service experience have shown that levels of noise from power lines at frequencies higher than 300 MHz are so low that interference is unlikely to be caused to television reception. The values of limits given as examples are calculated to provide a reasonable degree of protection to the reception of broadcasting at the boundary of the recognized service areas of the appropriate transmitters in the radio frequency bands used for a.m. broadcasting, in the least favourable conditions likely to be generally encountered. These limits are intended to provide guidance at the planning stage of the line and national standards or other specifications against which the performance of the line may be checked after construction and during its useful life. The measuring apparatus and methods used for checking compliance with limits should comply with the respective CISPR specifications, as e.g. the basic standards series CISPR 16, see [1]*. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050-161, International Electrotechnical Vocabulary (IEV) – Chapter 161: Electromagnetic compatibility IEC 60060-2, High-voltage test techniques – Part 2: Measuring systems

Radio interference characteristics of overhead power lines and high-voltage equipment – Part 2: Methods of measurement and procedure for determining limits TR

ICS
33.100.01
CCS
L06
发布
2010-01-01
实施
2010-06-01

This part of CISPR 18, which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception. The scope of this publication includes the causes, measurement and effects of radio interference, design aspects in relation to this interference, methods and examples for establishing limits and prediction of tolerable levels of interference from high voltage overhead power lines and associated equipment, to the reception of radio broadcast services. The frequency range covered is 0,15 MHz to 300 MHz. Radio frequency interference caused by the pantograph of overhead railway traction systems is not considered in this technical report.

Radio interference characteristics of overhead power lines and high-voltage equipment – Part 1: Description of phenomena TR

ICS
33.100.01
CCS
L06
发布
2010-01-01
实施
2010-06-01

Electromagnetic compatibility of technical equipment. Safety of household and similar electrical appliances when subjected to electromagnetic disturbances. Requirements and test methods

ICS
33.100.01
CCS
发布
2010
实施
2011-03-01

Electromagnetic compatibility of technical equipment. Specification for radio disturbance and immunity measuring apparatus and methods. Part 2-4. Methods of measurement of disturbances and immunity. Immunity parameters measurement

ICS
33.100.01
CCS
发布
2010
实施
2011-01-01

Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements (IEC/CISPR 16-2-1:2008); German version EN 55016-2-1:2009

ICS
33.100.01
CCS
发布
2009-12
实施
2009-12-01

Deals with the limitation of harmonic currents injected into the public supply system. Applies to equipment intended to be connected to low-voltage systems interfacing with the public supply at the low-voltage level.

Electromagnetic compatibility (EMC) Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and <=75 A per phase

ICS
33.100.01
CCS
发布
2009-10-23
实施
2009-10-23

Covers guidelines for the mitigation of external electromagnetic influences impinging upon a facility, aimed at ensuring electromagnetic compatibility (EMC) among electrical and electronic apparatus or systems. Is particularly concerned with the arrange

Electromagnetic compatibility (EMC) Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences

ICS
33.100.01
CCS
L06
发布
2009-10-23
实施

Electromagnetic compatibility techniques and requirements for instruments measuring quasi-peak, peak, rms, and average values for electrical and electronic equipment for various applications are provided.

American National Standard for Electromagnetic Noise and Field Strength Instrumentation, 10 Hz to 40 GHz Specifications

ICS
33.100.01
CCS
A42
发布
2009-10-20
实施

Specifies detailed test configurations, operational conditions and performance criteria for equipment with test and measurement circuits (both internal and/or external to the equipment) that are not EMC protected for operational and/or functional reasons

Electrical equipment for measurement, control and laboratory use - EMC requirements Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected a

ICS
33.100.01
CCS
L06
发布
2009-10-09
实施

Specifies detailed test configurations, operational conditions and performance criteria for equipment which is used for testing, measuring or monitoring of protective measures in low-voltage distribution systems, is powered by battery and/or from the cir

Electrical equipment for measurement, control and laboratory use - EMC requirements Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-

ICS
33.100.01
CCS
L06
发布
2009-10-09
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号