33.100.01 电磁兼容性综合 标准查询与下载



共找到 697 条与 电磁兼容性综合 相关的标准,共 47

Electromagnetic compatibility(EMC) — Part 5-6: Installation and mitigation guidelines — Mitigation of external EM influences

ICS
33.100.01
CCS
发布
2021-12-09
实施

Electromagnetic compatibility(EMC) — Part 5-3: Installation and mitigation guidelines — HEMP protection concepts

ICS
33.100.01
CCS
发布
2021-12-09
实施

Electromagnetic compatibility (EMC) - Part 2-10: Environment - Description of HEMP environment - Conducted disturbance

ICS
33.100.01
CCS
发布
2021-11-18
实施

1.1 This practice covers simplified methods for addressing High-Intensity Radiated Fields (HIRF) and the Indirect Effects of Lightning (IEL) on aircraft. The material was developed through open consensus of international experts in general aviation. This information was created by focusing on Aircraft Certification Level 1, Level 2, and Level 3 Normal Category aeroplanes. The content may be more broadly applicable. It is the responsibility of the applicant to substantiate broader applicability as a specific means of compliance. The topics covered within this practice are: Overview; Minimum Design Requirements; Aeroplane Assessment Level; HIRF and IEL Safety Analysis; HIRF Compliance; IEL Compliance. 1.2 An applicant intending to propose this information as Means of Compliance for a design approval must seek guidance from their respective oversight authority (for example, published guidance from applicable CAA) concerning the acceptable use and application thereof. For information on which oversight authorities have accepted this practice (in whole or in part) as an acceptable Means of Compliance to their regulatory requirements (hereinafter “the Rules”), refer to the ASTM Committee F44 web page (www.astm.org/ COMMITTEE/F44.htm). 1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Simplified Methods for Addressing High-Intensity Radiated Fields (HIRF) and Indirect Effects of Lightning on Aircraft

ICS
33.100.01
CCS
发布
2021-11-01
实施

Metallic communication cable test methods. Part 4-5: Electromagnetic compatibility (EMC) – Screening or coupling attenuation – Absorbing clamp method

ICS
33.100.01
CCS
K13
发布
2021-10-11
实施
2021-10-11

Metallic cables and other passive components test methods. Electromagnetic compatibility (EMC). Test method for measuring of transfer impedance Z<sub>T</sub> and screening attenuation a<sub>S</sub> or coupling a...

ICS
33.100.01
CCS
发布
2021-10-07
实施
2021-10-07

Metallic cables and other passive components test methods. Electromagnetic compatibility (EMC). Test method for measuring transfer impedance and screening attenuation. or coupling attenuation with triaxial cell

ICS
33.100.01
CCS
发布
2021-09-21
实施
2021-09-21

Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus (english version)

ICS
33.100.01
CCS
发布
2021-09-01
实施
2021-09-01

Railway applications - Electromagnetic compatibility - Part 3-1: Rolling stock - Train and complete vehicle (english version)

ICS
33.100.01
CCS
发布
2021-09-01
实施
2021-09-01

This document corrects DIN EN 12895 (VDE 0117-895):2020-03, \

Industrial trucks - Electromagnetic compatibility; German version EN 12895:2015+A1:2019; Corrigendum 2

ICS
33.100.01
CCS
发布
2021-08-00
实施

This standard contains the German version of EN IEC 55016-1-4:2019 + A1:2020 and is identical with the International Standard CISPR 16-1-4 (edition January 2019) and its Amendment A1:2020. The standard specifies requirements for antennae and measuring sites that are used for the

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements (CISPR 16-1-4:2019 + A1:2020); German version E

ICS
33.100.01
CCS
发布
2021-08-00
实施
2021-08-01

This technical report provides the guidelines for emission levels within the bands designated by the International Telecommunication Union (ITU) for industrial, scientific and medical (ISM) application.

Industrial, scientific and medical equipment (ISM) - Guidelines for emission levels within the bands designated by the ITU

ICS
33.100.01
CCS
发布
2021-07-01
实施

CISPR 17:2011 specifies methods to measure the radio interference suppression characteristics of passive EMC filtering devices used in power and signal lines, and in other circuits. The defined methods may also be applied to combinations of over-voltage protection devices and EMC filtering devices. The measurement method covers the frequency range from 9 kHz to several GHz depending on the device and test circuit. The standard describes procedures for laboratory tests (type tests) as well as factory tests. The suppression characteristics of EMC filters and components used for the suppression of EM disturbances, are a function of numerous variables such as impedance of the circuits to which they connect, operating voltage and current, and ambient temperature. This standard specifies uniform test methods that will enable comparison of filtering and suppression characteristics determined by test laboratories or specified by manufacturers. Measurement procedures are provided for unbiased and bias conditions. Measurements under bias conditions are performed to determine potential non-linear behaviour of the EMC filtering devices such as saturation effects in inductors with magnetic cores. This testing serves to show the usability in a specific application (such as frequency converters that produce high amplitudes of common mode pulse current and thus may drive inductors into saturation). Measurement under bias conditions may be omitted if the non-linear behaviour can be determined by other methods (e.g. separate saturation measurement of the inductors used). The first edition of CISPR 17 (1981) prescribed the measurement methods of insertion loss mainly for power-line filters. Today, however, many types of sophisticated EMC filters and suppression components can be found in various electronic devices. Those filters need to be characterized using standardized measurement methods. New methods for measurement of impedance and S-parameters for such EMI devices are included in this second edition.

Methods of measurement of the suppression characteristics of passive EMC filtering devices

ICS
33.100.01
CCS
发布
2021-07-01
实施

IEC/TR 60725:2012, which is a technical report, records the information that was available and the factors that were taken into account in arriving at the reference impedances that were incorporated in IEC 60555 and which are now incorporated in some parts of IEC 61000-3. In addition, information is given on the impedances of public supply networks associated with service current capacities ≤100 A per phase. The third edition includes brings two mainly significant technical changes with respect to the previous edition: - a new survey and other data from countries with public supply networks operating at 60 Hz have been included; and - recommendations that were applicable to 50 Hz systems are now mirrored by new recommendations that are relevant to 60 Hz systems.

Consideration of reference impedances and public supply network impedances for use in determining the disturbance characteristics of electrical equipment having a rated current ≤75 A per phase

ICS
33.100.01
CCS
发布
2021-07-01
实施

CISPR 18-1:2010(E), which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception. The scope of this publication includes the causes, measurement and effects of radio interference, design aspects in relation to this interference, methods and examples for establishing limits and prediction of tolerable levels of interference from high voltage overhead power lines and associated equipment, to the reception of radio broadcast services. The frequency range covered is 0,15 MHz to 300 MHz. Radio frequency interference caused by the pantograph of overhead railway traction systems is not considered in this technical report. This second edition cancels and replaces the first edition published in 1982. It is a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - while the first edition of CISPR 18-1 only covered the direct distance D0 for the establishment of standard profiles for the lateral radio noise field emanating from HV overhead power lines, - this second edition now also allows for use of the lateral distance y0 for these purposes. This way it allows for the establishment of standard profiles for the lateral radio noise field also from modern HV overhead power line constructions with tall suspension towers.

Radio interference characteristics of overhead power lines and high-voltage equipment - Part 1: Description of phenomena

ICS
33.100.01
CCS
发布
2021-07-01
实施

CISPR 18-2:2010(E), which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception. The frequency range covered is 0,15 MHz to 300 MHz. A general procedure for establishing the limits of the radio noise field from the power lines and equipment is recommended, together with typical values as examples, and methods of measurement. The clause on limits concentrates on the low frequency and medium frequency bands and it is only in these bands where ample evidence, based on established practice, is available. No examples of limits to protect radio reception in the frequency band 30 MHz to 300 MHz have been given, as measuring methods and certain other aspects of the problems in this band have not yet been fully resolved. Site measurements and service experience have shown that levels of noise from power lines at frequencies higher than 300 MHz are so low that interference is unlikely to be caused to television reception. The values of limits given as examples are calculated to provide a reasonable degree of protection to the reception of broadcasting at the boundary of the recognized service areas of the appropriate transmitters in the radio frequency bands used for a.m. broadcasting, in the least favourable conditions likely to be generally encountered. These limits are intended to provide guidance at the planning stage of the line and national standards or other specifications against which the performance of the line may be checked after construction and during its useful life. The measuring apparatus and methods used for checking compliance with limits should comply with the respective CISPR specifications, as e.g. the basic standards series CISPR 16. This second edition cancels and replaces the first edition published in 1986. It is a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - while the first edition of CISPR 18-2 only considered the direct distance D0 for the establishment of standard profiles for the lateral radio noise field emanating from HV overhead power lines, - this second edition now also allows for use of the lateral distance y0 for these purposes. This way it allows for conduction of on-site measurements and simplified recording and use of measurement data obtained at lateral distances y slant to the pathway of modern HV and UHV overhead power line constructions with tall suspension towers.

Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits

ICS
33.100.01
CCS
发布
2021-07-01
实施

CISPR 18-3:2010(E), which is a technical report, applies to radio noise from overhead power lines and high-voltage equipment which may cause interference to radio reception, excluding the fields from power line carrier signals. The frequency range covered is 0,15 MHz to 300 MHz. This second edition cancels and replaces the first edition published in 1986. It is a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - while the first edition of CISPR 18-3 only covered recommendations for minimizing the generation of radio noise emanating from high-voltage (HV) power systems, - this second edition now also covers a new clause providing formulae for predetermination of the radio noise field strength levels from HV overhead power lines with large conductor bundles. Furthermore, Annex A was accomplished with a collation of predetermination formulae developed and used by several institutions around the world. The tables also contain typical examples of radio noise field strength levels obtained during some measurements campaigns at several HV overhead power line constructions.

Radio interference characteristics of overhead power lines and high-voltage equipment - Part 3: Code of practice for minimizing the generation of radio noise

ICS
33.100.01
CCS
发布
2021-07-01
实施

IEC TR 61000-1-7:2016(E) provides definitions of various electrical power quantities and the relationship between them under non-sinusoidal conditions, in order to give clear information on both components in the power factor: - the fundamental power factor, which is due to the phase difference between the voltage and current at the fundamental frequency, and - the non-fundamental power factor, which is related to the distortion of the voltage and/or current. This Technical Report is applicable only to single-phase systems.

Electromagnetic compatibility (EMC) - Part 1-7: General - Power factor in single-phase systems under non-sinusoidal conditions

ICS
33.100.01
CCS
发布
2021-07-01
实施

Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteria - Part 1: General EMC requirements (ISO/DIS 14982-1:2021)

ICS
33.100.01
CCS
发布
2021-06-01
实施
2021-06-01

Agricultural and forestry machinery - Electromagnetic compatibility - Part 2: Additional EMC requirements for functional safety (ISO/DIS 14982-2:2021)

ICS
33.100.01
CCS
发布
2021-06-01
实施
2021-06-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号