This part of IEC 61156 is applicable to communication systems such as ISDN, local area networks and data communication systems and specifies the definitions, requirements and test methods of multicore, symmetrical pair and quad cables.This standard is also applicable to cables used for customer premises wiring.

Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification

ICS
33.120.20
CCS
发布
2007-11-19
实施
2007-11-19

This part 2-22 of EN 50290 gives specific requirements for PVC sheathing compounds used for communication cables. It is to be read in conjunction with Part 2-20 of EN 50290.

Communication cables - Part 2-22: Common design rules and construction - PVC sheathing compounds

ICS
33.120.20
CCS
发布
2007-11-12
实施
2007-11-12

This standard applies to the materials, constructions, and testing of weather-resistant polyethylene covered conductors rated at 75?C and 90?C normal service temperatures. Conductors covered under this standard are intended for the distribution of electrical energy under normal overhead (aerial) conditions and installations.

Weather-Resistant Polyethylene Covered Conductors

ICS
33.120.20
CCS
K12
发布
2007-09-27
实施

This part of IEC61156 is applicable to communication systems such as ISDN, local area networks and data communication systems and specifies the definitions, requirements and test methods of multicore, symmetrical pair and quad cables. This standard is also applicable to cables used for customer premises wiring.

Multicore and symmetrical pair/quad cables for digital communication - Part 1: Generic specification

ICS
33.120.20
CCS
K13
发布
2007-06
实施
2009-10-16

This part of IEC 61156 relates to IEC 61156-1. The cables described herein are intended for work area wiring as defined in I SO/I EC 11801. It covers individually screened, common screened and unscreened pairs or quads. The transmission characteristics and the frequency range (see Table 1) of the cables are specified at20°C. These cables can be used for various communication channels which use as many as four pairs simultaneously. In this sense, this sectional specification provides the cable characteristics required by system developers to evaluate new systems. The cables covered by this standard are intended to operate with voltages and currents normally encountered in communication systems. These cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains.

Multicore and symmetrical pair/quad cables for digital communications - Part 6: Symmetrical pair/quad cables with transmission characteristics up to 600 MHz - Work area wiring - Sectional specification

ICS
33.120.20
CCS
K13
发布
2007-06
实施
2010-01-25

This part of IEC 61156 describes symmetrical pair/quad cables intended for horizontal floor cabling in class D, E, EA, F and FA channels (Cat 5e, Cat 6, Cat 6, Cat 7, Cat 7) as defined in ISO/IEC 11801 and ISO/IEC 24702. NOTE Cabling for various severities of industrial environments is specified in ISO/IEC 24702. Environmental classifications are presented in ISO/IEC 24702 with three levels of severity in four areas: mechanical, ingress, climatic, and electromagnetic; thus, in tabular form, they are referred to as the "MICE table". This blank detail specification includes additional recommended environmental characteristics and severities, which are derived from the environmental classifications that are specified for cabling for industrial environments. The blank detail specification determines the layout and style for detail specifications describing symmetrical pair/quad cables with transmission characteristics up to 1 000 MHz for digital communications. Detail specifications, based on the blank detail specification, may be prepared by a national organization, a manufacturer, or a user.

Multicore and symmetrical pair/quad cables for digital communications - Part 5-1: Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz - Horizontal floor wiring - Blank detail specification

ICS
33.120.20
CCS
K13
发布
2007-06
实施
2009-10-16

This paart of IEC 61156 describes symmetrical pair/quad cables intended for working area cabling in class D, E, E, F and F channels (Cat 5e, Cat 6, Cat 6, Cat 7, Cat 7) as defined in ISO/IEC 11801 and ISO/IEC 24702. This blank detail specification includes additional recommended environmental characteristics and severities, which are derived from the environmental classifications that are specified for cabling for industrial environments. NOTE Cabling for various severities of industrial environments is specified in ISO/IEC 24702. Environmental classifications are presented in ISO/IEC 24702 with three levels of severity in four areas: mechanical, ingress, climatic, and electromagnetic: thus. in tabular form, they are referred to as the "MICE table". The blank detail specification determines the layout and style for detail specifications describing symmetrical pair/quad cables with transmission characteristics up to 1 000 MHz for digital communications. Detail specifications, based on the blank detail specification, may be prepared by a national organization, a manufacturer, or a user.

Multicore and symmetrical pair/quad cables for digital communications - Part 6-1: Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz - Work area wiring - Blank detail specification

ICS
33.120.20
CCS
K13
发布
2007-06
实施
2009-10-16

Cables for indoor residential telecommunication installations - Part 3: Screened cables - Grade 3; German version EN 50441-3:2006

ICS
33.120.20
CCS
K13
发布
2007-01
实施
2007-01-01

Cables for indoor residential telecommunication installations - Part 1 : un-screened cables - Grade 1.

ICS
33.120.20
CCS
K13
发布
2006-12-01
实施
2006-12-05

Cables for indoor residential telecommunication installations - Part 2 : screened cables - Grade 2.

ICS
33.120.20
CCS
K13
发布
2006-12-01
实施
2006-12-05

These cables are for installation in indoor Residential Cabling Systems. They are specified up to 100 MHz. Their design is based on the requirements of the EN 50290-2-1. They are specifically designed for cabling in residential environment supporting ICT and BCT applications. (Telephone, Computer and TV services). This specification defines the constructional details as well as the specific performances of the cables. Unless otherwise specified, all cables covered by this standard may be subjected to voltages not more than 300 V a.c. or 450 V d.c. and shall meet the essential requirements of the low voltage directive. Due to current limitation related to the conductor cross sectional area, they are not intended for direct connection to mains electricity supply. The maximum current rating per conductor is less than or equal to 3 A/mm? unless otherwise specified in the relevant detail specification.

Cables for indoor residential telecommunication installations - Unscreened cables - Grade 1

ICS
33.120.20
CCS
K13
发布
2006-09-29
实施
2006-09-29

These cables are for installation in indoor Residential Cabling Systems. They are specified up to 1 000 MHz. Their design is based on the requirements of the EN 50290-2-1. They are specifically designed for cabling in residential environment supporting ICT and BCT applications. (Telephone, Computer and TV services). This specification defines the constructional details as well as the specific performances of the cables. Unless otherwise specified, all cables covered by this standard may be subjected to voltages not more than 300 V a.c. or 450 V d.c. and shall meet the essential requirements of the low voltage directive. Due to current limitation related to the conductor cross sectional area, they are not intended for direct connection to mains electricity supply. The maximum current rating per conductor is less than or equal to 3 A/mm² unless otherwise specified in the relevant detail specification.

Cables for indoor residential telecommunication installations - Screened cables - Grade 3

ICS
33.120.20
CCS
K13
发布
2006-09-29
实施
2006-09-29

These cables are for installation in indoor Residential Cabling Systems. They are specified up to 100 MHz. Their design is based on the requirements of the EN 50290-2-1. They are specifically designed for cabling in residential environment supporting ICT and BCT applications. (Telephone, Computer and TV services). This specification defines the constructional details as well as the specific performances of the cables. Unless otherwise specified, all cables covered by this standard may be subjected to voltages not more than 300 V a.c. or 450 V d.c. and shall meet the essential requirements of the low voltage directive. Due to current limitation related to the conductor cross sectional area, they are not intended for direct connection to mains electricity supply. The maximum current rating per conductor is less than or equal to 3 A/mm? unless otherwise specified in the relevant detail specification.

Cables for indoor residential telecommunication installations - Screened cables - Grade 2

ICS
33.120.20
CCS
K13
发布
2006-09-29
实施
2006-09-29

This guide covers the diagnostic testing of new or service-aged installed shielded power cable systems, which include cable, joints, and terminations, using partial discharge (PD) detection, measurement, and location. Partial discharge testing, which is a useful indicator of insulation degradation, may be carried out on-line or off-line by means of an external voltage source. This guide does not include the testing of compressed gas insulated systems or continuous on-line monitoring at normal service voltage.

IEEE Guide for Partial Discharge Testing of Shielded Power Cable Systems in a Field Environment

ICS
33.120.20
CCS
K13
发布
2006-09-15
实施

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 1: Generic specification

ICS
33.120.20
CCS
K13
发布
2006-07
实施

The blank detail specification determines the layout and style for detail specifications describingMulticore and symmetrical pair/quad unfilled cables for broadband digital communications. Detailspecifications, based on the blank detail specification, may be prepared by a nationalorganization, a manufacturer, or a user.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 2-1: Unfilled cables - Blank detail specification

ICS
33.120.20
CCS
发布
2006-06-28
实施
2006-06-28

This sectional specification relates to IEC 62255-1.This standard is applicable to filled cables having a metallic screen over the cable core, apolyethylene jacket, copper conductors, and solid or cellular insulation. These cables are typicallyavailable in 6 to 300 pair.These cables are suitable for direct burial, installation into ducts, or installed aerially by lashing toa support strand. They may also be self-supporting by incorporation of an integral suspensionstrand.The cables covered by this specification are differentiated by bandwidth and are classified byhaving a maximum reference frequency of 30 MHz, 60 MHz, or 100 MHz.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 3: Filled cables - Sectional specification

ICS
33.120.20
CCS
发布
2006-06-28
实施
2006-06-28

The blank detail specification determines the layout and style for detail specifications describingMulticore and symmetrical pair/quad filled cables for broadband digital communications. Detailspecifications, based on the blank detail specification, may be prepared by a nationalorganization, a manufacturer, or a user.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 3-1: Filled cables - Blank detail specification

ICS
33.120.20
CCS
发布
2006-06-28
实施
2006-06-28

This sectional specification relates to IEC 62255-1.This standard is applicable to aerial drop cables with or without a metallic screen over the cablecore, a thermoplastic jacket, copper conductors, and solid or cellular insulation. These cables aretypically available in 2 to 6 pair.These cables are intended for aerial applications and are self-supporting.The cables covered by this specification are differentiated by bandwidth and are classified byhaving a maximum reference frequency of 30 MHz, 60 MHz, or 100 MHz.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 4: Aerial drop cables - Sectional specification

ICS
33.120.20
CCS
发布
2006-06-28
实施
2006-06-28

The blank detail specification determines the layout and style for detail specifications describingMulticore and symmetrical pair/quad aerial drop cables for broadband digital communications.Detail specifications, based on the blank detail specification, may be prepared by a nationalorganization, a manufacturer, or a user.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 4-1: Aerial drop cables - Blank detail specification

ICS
33.120.20
CCS
发布
2006-06-28
实施
2006-06-28