33.120.20 导线和对称电缆 标准查询与下载



共找到 508 条与 导线和对称电缆 相关的标准,共 34

The blank detail specification determines the layout and style for detail specifications describingMulticore and symmetrical pair/quad filled drop cables for broadband digital communications.Detail specifications, based on the blank detail specification, may be prepared by a nationalorganization, a manufacturer, or a user.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 5-1: Filled drop cables - Blank detail specification

ICS
33.120.20
CCS
发布
2006-06-28
实施
2006-06-28

This sectional specification relates to IEC 62255-1.This standard is applicable to filled drop cables having a metallic screen over the cable core, athermoplastic jacket, copper conductors, and solid or cellular insulation. These cables aretypically available in 2 to 6 pair.These cables are intended primarily for direct burial in the ground.The cables covered by this specification are differentiated by bandwidth and are classified byhaving a maximum reference frequency of 30 MHz, 60 MHz, or 100 MHz.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 5: Filled drop cables - Sectional specification

ICS
33.120.20
CCS
发布
2006-06-28
实施
2006-06-28

This sectional specification relates to IEC 62255-1.This standard is applicable to unfilled cables having a metallic screen over the cable core, apolyethylene jacket, copper conductors, and solid or cellular insulation. An inner polyethylenejacket under the metallic screen may be provided. These cables are typically available in 6 to300 pair.These cables are suitable for installation into ducts or installed aerially by lashing to a supportstrand or by being self-supporting. The self-supporting properties may be achieved by utilizing agalvanized steel strength member or by an integral or multi-layers of glass or synthetic reinforcingmembers.The cables covere

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 2: Unfilled cables - Sectional specification

ICS
33.120.20
CCS
发布
2006-06-28
实施
2006-06-28

Cables, wires and flexible cords for power install - Part 605: Screened flexible cable with rubber insulation and PVC sheath nominal voltage U0/U 3,6/6 kV and 6/10 kV

ICS
33.120.20
CCS
J33
发布
2006-06
实施
2006-06-01

This standard is intended to define polyolefin-insulated cables for insertion into local outdoor networks. This standard is applicable to polyolefin insulated and moisture barrier polyolefin sheated telephone cables, filled or unfilled with copper conductors, and used as: a) Cables suitable for installation in ducts; b) Cables suitable for direct burial in the ground; c) Cables with integral suspension strand for aerial installations.

Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath (IEC 60708:2005); German version EN 60708:2005

ICS
33.120.20
CCS
G33
发布
2006-04
实施
2006-04-01

Multi-element metallic cables used in analogue and digital communication and control - Part 7: Sectional specification for instrumentation and control cables; German version EN 50288-7:2005

ICS
33.120.20
CCS
K13
发布
2006-03
实施
2006-03-01

Is intended to define polyolefin insulated cables for insertion into local outdoor networks.is applicable to polyolefin insulated and moisture barrier polyolefin sheathed telephone cables, filled or unfilled with copper conductors,includes general design details and requirements for dimensions and other constructional details as well as mechanical, electrical and environmental characteristics for all types of low-frequency cables with polyolefin insulation (solid or cellular), filled or unfilled

Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath

ICS
33.120.20
CCS
发布
2006-02-27
实施
2006-02-27

This sectional specification relates to IEC 62255-1. This standard is applicable to unfilled cables having a metallic screen over the cable core, a polyethylene jacket, copper conductors, and solid or cellular insulation. An inner polyethylene jacket under the metallic screen may be provided. These cables are typically available in 6 to 300 pair. These cables are suitable for installation into ducts or installed aerially by lashing to a support strand or by being self-supporting. The self-supporting properties may be achieved by utilizing a galvanized steel strength member or by an integral or multi-layers of glass or synthetic reinforcing members. The cables covered by this specification are differentiated by bandwidth and are classified by having a maximum reference frequency of 30 MHz, 60 MHz, or 100 MHz.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 2: Unfilled cables - Sectional specification

ICS
33.120.20
CCS
K13
发布
2006-01
实施

The blank detail specification determines the layout and style for detail specifications describing Multicore and symmetrical pair/quad unfilled cables for broadband digital communications. Detail specifications, based on the blank detail specification, may be prepared by a national organization, a manufacturer, or a user.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 2-1: Unfilled cables - Blank detail specification

ICS
33.120.20
CCS
K13
发布
2006-01
实施

This sectional specification relates to IEC 62255-1. This standard is applicable to filled cables having a metallic screen over the cable core, a polyethylene jacket, copper conductors, and solid or cellular insulation. These cables are typically available in 6 to 300 pair. These cables are suitable for direct burial, installation into ducts, or installed aerially by lashing to a support strand. They may also be self-supporting by incorporation of an integral suspension strand. The cables covered by this specification are differentiated by bandwidth and are classified by having a maximum reference frequency of 30 MHz, 60 MHz, or 100 MHz.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 3: Filled cables - Sectional specification

ICS
33.120.20
CCS
K13
发布
2006-01
实施

The blank detail specification determines the layout and style for detail specifications describing Multicore and symmetrical pair/quad filled cables for broadband digital communications. Detail specifications, based on the blank detail specification, may be prepared by a national organization, a manufacturer, or a user.

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 3-1: Filled cables - Blank detail specification

ICS
33.120.20
CCS
K13
发布
2006-01
实施

This sectional specification covers multi-element cables suitable for connecting instruments and control systems for analogue or digital signal transmission. They may or may not be screened and optionally may incorporate armouring and/ar moisture or environmental protection layers.

Multi-element metallic cables used in analogue and digital communication and control -- Part 7: Sectional specification for instrumentation and control cables

ICS
33.120.20
CCS
发布
2005-12-09
实施
2005-12-09

1.1 This specification covers ACSR Twisted Pair Conductor (ACSR/TP) for use as overhead electric conductors (see Note 0Note 0).Note 0The conductor is fabricated from two component ACSR conductors of the same size twisted helically around each other. This conductor is identified by the code name of the component ACSR conductor followed by /TP or the size and type of the component ACSR conductor followed by /TP.Note 0There are registered trademark symbols that are also used to identify the twisted pair notation. Consult cable manufacturers for additional details.1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. Each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. For conductor sizes designated by AWG or kcmil, the requirements in SI units have been numerically converted from corresponding values stated or derived in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units.1.2.1 For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for ACSR Twisted Pair Conductor (ACSR/TP)

ICS
33.120.20
CCS
发布
2005-10-01
实施

Communication cables. Specifications for test methods. Part 1 12: Electrical test methods. Inductance

ICS
33.120.20
CCS
发布
2005-07-15
实施
2005-07-15

This Part 1-12 of EN 50289 details the test methods to determine the inductance characteristics of cables used in analogue and digital communication systems. It is to be read in conjunction with EN 50289-1-1, which contains essential provisions for its application.

Communication cables - Specifications for test methods -- Part 1-12: Electrical test methods - Inductance

ICS
33.120.20
CCS
发布
2005-06-27
实施
2005-06-27

This standard is intended to define polyolefin-insulated cables for insertion into local outdoor networks. This standard is applicable to polyolefin insulated and moisture barrier polyolefin sheathed telephone cables, filled or unfilled with copper conductors, and used as: a) Cables suitable for installation in ducts. b) Cables suitable for direct burial in the ground. c) Cables with integral suspension strand for aerial installations. This standard is in accordance with ITU-T Recommendations. This standard includes general design details and requirements for dimensions and other constructional details as well as mechanical, electrical and environmental characteristics for all types of low-frequency cables with polyolefin insulation (solid or cellular), filled or unfilled, and moisture barrier polyolefin sheath (with integral suspension strand).

Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath

ICS
33.120.20
CCS
K13
发布
2005-06
实施
2005-06-27

Establishes generic technical requirements that may be referenced by individual telecommunications cable specifications covering products intended for normal indoor premises use in the wiring systems of communications users.

Riser Cable

ICS
33.120.20
CCS
K13
发布
2005-03-11
实施

This European Standard defines outdoor multi-pair cables for use in high bit rate digital telecommunication networks with their relative definitions and requirements. It covers water tight cables, with an overall screen, for applications up to 10 MHz, to be used in outdoor networks (for example in the subscriber access loop). The electrical, mechanical, transmission performance characteristics of the screened cables, related to their reference test methods, are detailed.#,,#

Multi-pair cables used in high bit rate digital access telecommunication networks - Part 1: Outdoor cables; German version EN 50407-1:2004

ICS
33.120.20
CCS
K13
发布
2005-02
实施
2005-02-01

End user multi-pair cables used in high bit rate telecommunication networks - Part 2: Duct and buried cables; German version EN 50406-2:2004

ICS
33.120.20
CCS
K13
发布
2005-02
实施
2005-02-01

This European Standard defines outdoor multi-pair/quad cables for use in high bit rate telecommunication networks with their relative definitions and requirements. It covers radially water blocked cables, with an overall screen, with performances up to 60 MHz, to be used in outdoor networks intended to connect the broadband outside plant to the individual customer premises with a maximum recommended length of connection of 1 km.#,,#

End user multi-pair cables used in high bit rate telecommunication networks - Part 1: Aerial cables; German version EN 50406-1:2004

ICS
33.120.20
CCS
K13
发布
2005-02
实施
2005-02-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved