33.120.20 导线和对称电缆 标准查询与下载



共找到 508 条与 导线和对称电缆 相关的标准,共 34

1 This standard applies to 60-250°C single- or multiple-conductor jacketed or unjacketed, integral or nonintegral cables and single or multiple coaxial cables for telephone and other communication circuits such as voice, data, and audio for on-premise customer systems. These cables ale not prohibited from containing one or more optical fibre members. For the purpose of this standard, a coaxial cable or coaxial member conductor is a single conductor with a shield. For the purpose of this standard, a single- or multiple-conductor unjacketed cable is a cross-connect wire. 2 This standard applies to communications cables that are intended primarily for installation in accordance with Section 60 of the Canadian Electrical Code (CEC), Part 1, and Article 800 of the National Electrical Code (NEC) . They are rated for 300 V applications but are not so marked.

Communications cables

ICS
33.120.20
CCS
K13
发布
2002-03-29
实施

This sectional specification relates to IEC 61156-1: Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification. The cables described herein are specifically intended for horizontal floor wiring in class D, E and F channels, as defined in ISO/IEC 11801:2000, Information technology - Generic cabling for customer premises (see Table 1). It covers individually screened (STP), common screened (FTP) and unscreened (UTP) pairs or quads having a pair count of four pairs or less. The transmission characteristics of the cables are specified at 20 ℃. See Annex A for a discussion of cable performance at temperatures higher than 20 ℃. The designation "Category 5e" is used herein to describe an enhanced Category 5 cable and is used in the same context as "Category 5" in ISO/IEC 11801. This enhanced cable is designated Category 5e to differentiate it from the Category 5 cables described in IEC 61156-2, 61156-3, and 61156-4. Although both Category 5 and 5e cables are characterized to 100 MHz and can be used in Class D channels, Category 5e has additional requirements, as compared to Category 5, which make it preferred for use in systems utilizing four pairs transmitting simultaneously in both directions. These cables can be used for various communication systems that are under development and which use as many as four pairs simultaneously. In this sense, this sectional specification provides the cable characteristics required by system developers to evaluate new systems. The cables covered by this sectional specification are intended to operate with voltages and currents normally encountered in communication systems. These cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains. Though the recommended temperature range during installation is 0 ℃ +50 ℃, the actual temperature range during installation should be indicated in the detail specification.

Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables with transmission characteristics up to 600 MHz; Horizontal floor wiring; Sectional specification

ICS
33.120.20
CCS
K13
发布
2002-03
实施
2009-02-26

This sectional specification relates to IEC 61156-1: Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification. The cables described herein are specifically intended to construct patch, equipment, and work area cords for class D, E arid F channels, as defined in IEC 11801:2000, Information technology - Generic cabling for customer premises (see Table 1). It covers individually screened (STP), common screened (FTP) and unscreened (UTP) pairs or quads having a pair count of four pairs or less. The transmission characteristics of the cables are specified at 20 ℃. See Annex A of IEC 61156-5 for a discussion of cable performance at temperatures higher than 20 ℃. The designation "Category 5e" is used herein to describe an enhanced Category 5 cable and is used in the same context as "Category 5" in ISO/IEC 11801. This enhanced cable is designated Category 5e to differentiate it from the Category 5 cables described in IEC 61156-2, 61156-3, and 61156-4. Although both Category 5 and 5e cables are characterized to 100 MHz and can in used for Class D channels, Category 5e has additional requirements, as compared to Category 5, which make it preferred for use in systems utilizing four pairs transmitting simultaneously in both directions. These cables are intended for various new communication systems that are under development and which use as many as four pairs simultaneously. In this sense, this sectional specification provides the cable characteristics required by system developers to evaluate new systems. The cables covered by this sectional specification are intended to operate with voltages and currents normally encountered in communication systems. These cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains. Though the recommended temperature range during installation is 0 ℃ +50 ℃, the actual temperature range during installation should be indicated in the detail specification.

Multicore and symmetrical pair/quad cables for digital communications - Part 6: Symmetrical pair/quad cables with transmission characteristics up to 600 MHz; Work area wiring; Sectional specification

ICS
33.120.20
CCS
K13
发布
2002-03
实施
2007-06-07

Mounting cable with PVC insulation and PVC sheath for excange equipment,type TC 44

ICS
33.120.20
CCS
发布
2002
实施

The cables referenced in this technical specification are intended for generic cabling systems, having solid conductors and with a pair count of four pairs or less. Their electrical performance requirements are laid out such that a margin of 3 dB is guaranteed for the channel, which approximately corresponds to 10 dB per 100 m of cable, if the connecting hardware and the patch cords are taken into account. The cables may be provided without a screen, with a common screen or with individual screens over the pairs. These cables are intended for various new communication systems, which are under development, and which may use as many as four pairs simultaneously. In this sense, the present specification is intended as a working document for system developers, to allow the evaluation of complete systems from a technical and also from an economic point of view. The cables covered by this specification are intended to operate with the voltage and current levels normally encountered in communication systems. These cables are not intended to be used in conjunction with low impedance sources, for example the electric power supplies of public utility mains. The recommended temperature range during installation may be indicated in the detail specification. The operating temperature range is at least -20 ℃ to +60 ℃ in order to ensure that a connected link remains operational under normal temperature variations. (The output and receive amplifiers go, upon power-up, through a training which takes the line condition into account and compensates for it. After training, the amplifiers are locked, to maintain the established parameters. If the line conditions are changed beyond the specified level, then the bit error rate of the linecard exceeds the permissible threshold and the link is interrupted.)

State of the art for symmetrical pair/quad cables with transmission characteristics beyond category 5

ICS
33.120.20
CCS
K13
发布
2001-02
实施

This part of IEC 61156 which is a generic specification applies to Capability Approval requirements for multicore and symmetrical pair/quad cables for digital communications as specified in IEC 61156-1 series. It specifies the requirements for a manufacturer seeking approval of his capability to design (if applicable), manufacture, inspect, test and release multicore and symmetrical pair/quad cables for digital communications as defined in his Capability Manual. The manufacturer's approval, which embodies all the relevant requirements of ISO 9001 and ISO 9002, is a prerequisite for granting Capability Approval but a manufacturer may apply for manufacturer's approval and Capability Approval concurrently. NOTE 1 This standard was written, to be used in case of a third party certification. However, it may be used as the basis for a second party or for self-certification. NOTE 2 When certification is required, Capability Approval should be used according to that which is indicated below. It may also be used for a second party or for self-certification.

Multicore and symmetrical pair/quad cables for digital communications - Part 1-1: Capability approval; Generic specification

ICS
33.120.20
CCS
K13
发布
2001-02
实施
2001-03-15

This part of IEC 61156, which is a sectional specification applies to Capability Approval requirements for cables for digital communications in horizontal floor wiring according to IEC 61156-1 and IEC 61156-2. Clause 2 is related to the content of the Capability Manual. Clause 3 is related to the Quality Plans. Clause 4 is related to the maintenance of Capability Approval. NOTE Quality assessment depends on the negotiation between customers and manufacturers. The following clause intends to be a guide when there is a request for a third party Capability Approval. However, it may be used also as the basis for second party or self-certification.

Multicore and symmetrical pair/quad cables for digital communications - Part 2-2: Horizontal floor wiring; Capability approval; Sectional specification

ICS
33.120.20
CCS
K13
发布
2001-02
实施
2001-03-15

This part of IEC 61156 which is a sectional specification applies to Capability Approval requirements for cables for digital communications in work area wiring according to IEC 61156-1 and IEC 61156-3. Clause 2 is related to the content of the Capability Manual. Clause 3 is related to the Quality Plans. Clause 4 is related to the maintenance of Capability Approval. NOTE Quality assessment belongs to the negotiation between customers and manufacturers. The following clause intends to be a guide when there is a request for a third party Capability Approval. However, it may be used also as the basis for second party or self-certification.

Multicore and symmetrical pair/quad cables for digital communications - Part 3-2: Work area wiring; Capability approval; Sectional specification

ICS
33.120.20
CCS
K13
发布
2001-02
实施
2001-03-15

This part of IEC 61156 which is a sectional specification applies to Capability Approval requirements for multicore and symmetrical pair cables for digital communication riser cables according to IEC 61156-1 and 61156-4. Clause 2 is related to the content of the Capability Manual. Clause 3 is related to the Quality Plans. Clause 4 is related to the maintenance of Capability Approval. NOTE Quality assessment belongs to the negotiation between customers and manufacturers. The following clause intends to be a guide when there is a request for a third party Capability Approval. However, it may be used also as the basis for second party or self-certification.

Multicore and symmetrical pair/quad cables for digital communications - Part 4-2: Riser cables; Capability approval; Sectional specification

ICS
33.120.20
CCS
K13
发布
2001-02
实施
2001-03-15

Copper-clad aluminum wire

ICS
33.120.20
CCS
L91
发布
2000-10-01
实施
2000-10-01

Provides the requirements used in the design of the telecommunications pathways and spaces, and the cabling installed between buildings or points in a customer-owned campus environment.

Customer-Owned Outside Plant Telecommunications Cabling

ICS
33.120.20
CCS
K13
发布
1999
实施

1.1 This specification covers “iron” wire with Class A, Class B, and Class C zinc coatings, suitable for use in telephone, telegraph, and signal transmission. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are for information only.

Standard Specification for Zinc-Coated (Galvanized) “Iron” Telephone and Telegraph Line Wire

ICS
33.120.20
CCS
K11
发布
1999
实施

Specifies minimum requirements for customer-owned OSP telecommunications facilities in a campus environment. The standard specifies the cabling, and the pathways and spaces to support the cabling. This standard was listed in the April 24, 1998 and August 14, 1998 issues of Standards Action. It is being resubmitted due to substantive changes to the text.

Customer-Owned Outside Plant Telecommunications Cabling

ICS
33.120.20
CCS
K13
发布
1999
实施

Low-frequency cables and wires with p.v.c. insulation and p.v.c. sheath - Part 2: Cables in pairs, triples, quads and quintuples for inside installations; Amendment 2

ICS
33.120.20
CCS
K12
发布
1996-11
实施

This sectional specification covers the equipment cables used for internal and external interconnections of electronic devices in networks for digital and analogue communications.

Sectional specification for equipment cables to be used for digital and analogue communication

ICS
33.120.20
CCS
发布
1996-05-24
实施
1996-02-14

Informs and familiarizes the reader with shielding practice. An overview of shielding practice, systems and test methods is provided.

IEEE Guide on shielding practice for low voltage cables

ICS
33.120.20
CCS
发布
1994-09-22
实施
1995-04-13

Informs and familiarizes the reader with shielding practice. An overview of shielding practice, systems and test methods is provided.

Guide on Shielding Practice for Low Voltage Cables

ICS
33.120.20
CCS
K13
发布
1994-09-22
实施
1995-04-13

Data-processing cable

ICS
33.120.20
CCS
K13
发布
1993-12
实施
1993-12-28

This amendment forms apart of MIL-F-85744(AS), dated 4 March 1987, and is approved for use by the Naval Air Systems Command, Department of the Navy and is available for use by all Departments and Agencies of the Department of Defense.

FUZE, PROXIMITY, DISPENSER FMU-140/B

ICS
33.120.20
CCS
M64
发布
1993-05-07
实施

This standard is Low-frequency cables and wires with PVC insulation and PVC sheath; part 5: equipment wires and cables with solid or stranded conductors, PVC insulated, screened, single or one pair; amendment 2.

Low-frequency cables and wires with PVC insulation and PVC sheath; part 5: equipment wires and cables with solid or stranded conductors, PVC insulated, screened, single or one pair; amendment 2

ICS
33.120.20
CCS
K12
发布
1992-04-01
实施
2014-12-17



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved