Photography-Direct-exposing medical and dental radiographic film/process systems- Determination of ISO speed and ISO average gradient
이 규격은 유방 뢴트겐선 조영법이 아닌 의료 및 치과용 방사선학에서 사용되는 필름/처리
Photography-Direct-exposing medical and dental radiographic film/process systems- Determination of ISO speed and ISO average gradient
Photography-Intra-oral dental radiographic film-Specification
이 규격은 의료용 방사선 카세트, 스크린 및 필름에 대한 호칭 크기, 허용 오차를 가진
Photography-Medical radiographic cassettes/screens/films and hard-copy imaging films-Dimensions and specifications
Photography-Direct-exposing medical and dental radiographic film/process systems- Determination of ISO speed and ISO average gradient
This International Standard specifies methods for determining sensitometric curve shape, ISO speed, ISO average gradient and ISO gradients G2 and 64 for industrial radiographic systems consisting of film and film processing when exposed directly to X-rays and γ-rays. The measurement of characteristics of film systems used in industrial radiography with fluorescent intensifying screens is not specified in this International Standard. NOTE Units of measured energy are given for information in annex A.
Photography. Industrial radiographic films. Determination of ISO speed, ISO average gradient and ISO gradients G2 and G4 when exposed to X- and gamma-radiation
This International Standard specifies methods for determining sensitometric curve shape, ISO speed, ISO average gradient and ISO gradients G2 and 64 for industrial radiographic systems consisting of film and film processing when exposed directly to X-rays and γ-rays. The measurement of characteristics of film systems used in industrial radiography with fluorescent intensifying screens is not specified in this International Standard. NOTE Units of measured energy are given for information in annex A.
Photography - Industrial radiographic films - Determination of ISO speed, ISO average gradient and ISO gradients G2 and 64 when exposed to X- and gamma-radiation
This International Standard specifies the nominal sizes, aim dimensions with tolerances, weights, and certain tests for medical radiographic cassettes, screens, and films. It includes medical hard-copy imaging films in the form of sheets, such as laser films and video. This International Standard also includes information regarding the appropriate marking of these products, and special attention is given to cassettes/screens/films used for mammography. This International Standard does not include films in roll format (see informative annex A).
Photography - Medical radiographic cassettes/screens/films and hard-copy imaging films - Dimensions and specifications
This International Standard specifies the nominal sizes, aim dimensions with tolerances, weights, and certain tests for medical radiographic cassettes, screens, and films. It includes medical hard-copy imaging films in the form of sheets, such as laser films and video. This International Standard also includes information regarding the appropriate marking of these products, and special attention is given to cassettes/screens/films used for mammography. This International Standard does not include films in roll format (see informative annex A).
Photography - Medical radiographic cassettes/screens/films and hard-copy imaging films - Dimensions and specifications
This International Standard specifies the nominal sizes, aim dimensions with tolerances, weights, and certain tests for medical radiographic cassettes, screens, and films. It includes medical hard-copy imaging films in the form of sheets, such as laser films and video. This International Standard also includes information regarding the appropriate marking of these products, and special attention is given to cassettes/screens/films used for mammography. This International Standard does not include films in roll format (see informative annex A).
Photography - Medical radiographic cassettes/screens/films and hard-copy imaging films - Dimensions and specifications
Photography. Industrial radiographic films (roll and sheet) and metal intensifying screens. Dimensions
This International Standard specifies the preferred and recognized sizes and cutting dimensions of industrial radiographic roll and sheet films and metal intensifying screens. It also specifies package markings. The shaping of the corners of screens is not specified.
Photography - Industrial radiographic films (roll and sheet) and metal intensifying screens - Dimensions
Настоящий стандарт распространяется на рентгенографические кассеты и сменщики пленки, используемые в прямой рентгенографии для регистр
Evaluation and routine testing in medical imaging departments. Part 2-2. Constancy tests. Radiographic cassettes and film changers. Film-screen contact and relative sensitivity of the screen-cassette assembly
This International Standard specifies the preferred and recognized sizes and cutting dimensions of industrial radiographic roll and sheet films and metal intensifying screens. It also specifies package markings. The shaping of the corners of screens is not specified.
Photography - Industrial radiographic films (roll and sheet) and metal intensifying screens - Dimensions
The document describes methods for the determination of the sensitometric curve shape, of the average gradient and of the speed of radiographic systems containing film, intensifying screens, film holding device and film processing as used in mammography.#,,#
Sensitometry of screen-film systems for medical radiography - Part 3: Method for determination of sensitometric curve shape, speed and average gradient for mammography
This part of ISO 9236 specifies methods for determination of the sensitometric curve shape, average gradient and speed of a single sample of a screen/film/filmholder/processing system in mammography. The filmholder may be any means which ensures close screen/film contact and prevents the film from being exposed to ambient light. In particular, the filmholder may be a light-tight vacuum bag, as often used in the laboratory, or a radiographic cassette as used in mammography. NOTE—Hereafter, screen/film/filmholder combinations will be referred to as "combinations", and will be referred to as "systems" when the processing is included.
Photography - Sensitometry of screen/film systems for medical radiography - Determination of sensitometric curve shape, speed and average gradient for mammography
This part of ISO 9236 specifies methods for determination of the sensitometric curve shape, average gradient and speed of a single sample of a screen/film/filmholder/processing system in mammography. The filmholder may be any means which ensures close screen/film contact and prevents the film from being exposed to ambient light. In particular, the filmholder may be a light-tight vacuum bag, as often used in the laboratory, or a radiographic cassette as used in mammography. NOTE — Hereafter, screen/film/filmholder combinations will be referred to as "combinations", and will be referred to as "systems" when the processing is included.
Photography - Sensitometry of screen/film systems for medical radiography - Part 3: Determination of sensitometric curve shape, speed and average gradient for mammography
Настоящий стандарт распространяется на кассеты для общей рентгенографии и маммографии, предназначенные для использования с рентгеногра
Cassettes for medical X-ray diagnosis. Radiographic and mammographic cassettes
Specifies dimensions for the commonly used range of cassettes for radiographic and mammographic procedures. This Standard is identical with and has been reproduced from IEC 60406:1997.
Cassettes for medical X-ray diagnosis - Radiographic cassettes and mammographic cassettes
この規格は,工業用放射線フィルムにおけるフィルムシステムクラスの定義並びに階調度及び粒状度の求め方について規定する。
Non-destructive testing -- Industrial radiographic films -- Part 1: Classification of film systems for industrial radiography