共找到 169 条与 黑色金属合金综合 相关的标准,共 12 页
This test is intended to evaluate in an accelerated manner, the resistance of component parts to deterioration resulting from high humidity and heat conditions typical of tropical environments.
Passive Electronic Component Parts, Test Methods for; Method 2: Moisture Resistance (Cycling)
The salt spray test is performed for the purpose of determining the adequacy of protective coatings or finishes, and has been widely used to evaluate the resistance of metals to corrosion in marine service or in exposed shore.locations. This test has prov
Passive Electronic Component Parts, Test Methods for; Method 5: Salt Spray (Corrosion)
This Standard is intended to be a guide to the selection of contact dimensions and tolerances in the early design phase of an electrical connector.
Electrical Connectors, Small Contact Standard for
This Test Method forms a part of the EIA Standard RS-186 which contains test guidance, definitions and standard test conditions.
Passive Electronic Component Parts, Test Methods for; Method 7: Vibration Fatigue Test (Low Frequency, 10 to 55 Hertz)
This Standard establishes uniform methods for testing electronic component parts. In case of conflict between this Standard and any individual component standards or detail specifications, the requirements of the individual component standard or detail sp
Passive Electronic Component Parts, Test Methods for; General Instructions and Index of Tests
This standard provides procedures for inspecting and testing trical, and environmental requirements of individual relay specifications.
Testing Procedures for Relays for Electrical and Electronic Equipment
This standard defines a test for solderability of solid lead wires, terminals, and conductive accessories of component parts which are to be joined b a soldering operation involving the use of rosin type wires not greater than 0.045 inch (1.14 mm) in diam
Passive Electronic Component Parts, Test Methods for; Method 9: Solderability
This Test Method forms a part of the EIA Standard RS-186 which contains test guidance, definitions and standard test conditions.
Passive Electronic Component Parts, Test Methods for; Method 6: Mechanical Robustness of Terminals
This Test Method forms a part of the EIA Standard RS-186 which contains test guidance, definitions and standard test conditions.
Passive Electronic Component Parts, Test Methods for; Method 3: Humidity (Steady State-Sealed Container)
This Test Method forms a part of the EIA Standard RS-186 which contains test guidance, definitions and standard test conditions.
Passive Electronic Component Parts, Test Methods for; Method 4: Dielectric Test (Withstanding Voltage)
This test is performed to determine the effect of normal soldering operations on component parts.
Passive Electronic Component Parts, Test Methods for; Method 10: Effect of Soldering
This Test Method forms a part of the EIA Standard RS-186 which contains test guidance, definitions and standard test conditions.
Passive Electronic Component Parts, Test Methods for; Method 13: Insulation Resistance Test
This Test Method forms a part of the EIA Standard RS-186 which contains test guidance, definitions and standard test conditions.
Passive Electronic Component Parts, Test Methods for; Method 12: Heat-Life Test
This Test Method forms a part of the EIA Standard RS-186 which contains test guidance, definitions and standard test conditions.
Passive Electronic Component Parts, Test Methods for; Method 11: Thermal Shock in Air
This test is intended to evaluate the effect of absorption and diffusion of moisture and moisture vapor on component parts. The test in an artificial environmental test, accelerated to shorten the testing time.
Passive Electronic Component Parts, Test Methods for; Method 1: Humidity (Steady State)
Radioactive isotopes are, on occasion, intentionally added by manufacturers of electron tubes to improve tube performance may be required to determine the total radioactivity in microcuries per tube (pc/tube) to comply with existing Federal regulations. I
Electron Tube Radioactivity Calculations in Microcuries/Tube
This Standard covers iron-core. power filter inductors for use in electronic equipment where long life,reliability and continuity of operation are essential.
Power Filter Inductors for Electronic Equipment
The demand for higher power output from microwave tubes has lead the tube designer to the use of higher voltages and currents to achieve these demands and currents makes it possible for the device to generate unwanted x-radiation.The use of high voltages
X-Radiation Detection and Measurements for Microwave Tubes, Recommended Practice on
Cross-section-The cross-section shall be square 0.750” tr .005” measured inside.
Midget I.F. Shields (.75 inch Square) (Reaffirmation of REC-144)
The nomenclature and symbols listed below refer to a generalized tube of the display storage type as shown in the accompanying diagram.