77.150.10 (Aluminium products) 标准查询与下载



共找到 221 条与 相关的标准,共 15

1.1 This practice establishes the controls required for hot rolling mill solution heat treatment of the 6xxx series aluminum alloy plate in Table 1 when ASTM material specifications allow use of this process in lieu of furnace solution heat treatment. For the alloys listed in Table 1, this practice is an alternate process to solution heat treatment in a furnace, such as specified in Practice B918 as the preliminary step for the attainment of T651-type tempers (see ANSI H35.1).TABLE 1 Ingot High Limit TemperatureA Alloy Ingot Upper Limit Temperature °F [°C] 6061 1050 [565] A8201;These upper limit temperatures avoid the possibility of eutectic melting due to overheating, and include a safety factor of approximately 25°F [15°C]. 1.2 This practice applies only to hot rolling mill solution heat treatment of plate for the listed aluminum alloys. Precipitation hardening (aging) processing and equipment calibration for aging shall meet the practice and requirements of Practice B918. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Hot Rolling Mill Solution Heat Treatment for Aluminum Alloy Plate

ICS
77.150.10 (Aluminium products)
CCS
J62
发布
2006
实施

1.1 This specification covers zirconium and zirconium-alloy castings for general corrosion-resistant and industrial applications.1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.

Standard Specification for Castings, Zirconium-Base, Corrosion Resistant, for General Application

ICS
77.150.10 (Aluminium products)
CCS
J31
发布
2006
实施

1.1 This specification covers aluminum-alloy investment castings designated as shown in Table 1.1.2 This specification is not intended for aluminum-alloy investment castings used in aerospace applications.1.3 Alloy and temper designations are in accordance with ANSI H35.1/H35.1(M). The equivalent Unified Numbering System alloy designations are in accordance with Practice E 527. 1.4 For acceptance criteria for inclusion of new aluminum and aluminum alloys and their properties in this specification, see Annex A1 and Annex A2.1.5 Units8212;The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units which are provided for information only and are not considered standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Aluminum-Alloy Investment Castings

ICS
77.150.10 (Aluminium products)
CCS
H61
发布
2006
实施

1.1 This specification covers aluminum and aluminum-alloy flat sheet, coiled sheet, and plate in the alloys (Note 1) and tempers shown in Table 2 and 3, and in the following finishes:1.1.1 Plate in all alloys and sheet in heat-treatable alloys: mill finish.1.1.2 Sheet in nonheat-treatable alloys: mill finish, one-side bright mill finish, standard one-side bright finish, and standard two-sides bright finish.Note 18212;Throughout this specification, use of the term alloy in the general sense includes aluminum as well as aluminum alloy.Note 28212;See Specification B 632/B 632M for tread plate.Note 38212;See Specification B 928/B 928M for marine sheet and plate. Due to additional corrosion testing required, it is not intended that Specification B 209 be used for marine sheet and plate.1.2 Alloy and temper designations are in accordance with ANSI H35.1/H35.1(M). The equivalent Unified Numbering System alloy designations are those of Table 1 preceded by A9, for example, A91100 for aluminum 1100 in accordance with Practice E 527.1.3 A complete metric companion to Specification B 209 has been developed-Specification B 209M; therefore, no metric equivalents are presented in this specification.1.4 For acceptance criteria for inclusion of new aluminum and aluminum alloys in this specification, see Annex A2.

Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate

ICS
77.150.10 (Aluminium products)
CCS
H61
发布
2006
实施

1.1 This specification covers zirconium and zirconium-alloy castings for general corrosion-resistant and industrial applications. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Standard Specification for Castings, Zirconium-Base, Corrosion Resistant, for General Application

ICS
77.150.10 (Aluminium products)
CCS
J31
发布
2006
实施

1.1 This specification covers two grades of wrought hafnium and hafnium alloy strip, sheet, and plate as follows:1.1.1 Grade R1 for nuclear applications, and1.1.2 Grade R3 for commercial applications.1.2 Unless a single unit is used, for example corrosion mass gain in mg/dm2, the values stated in either inch-pound or SI units are to be regarded separately as standard. The values stated in each system are not exact equivalents; therefore each system must be used independently of the other. SI values cannot be mixed with inch-pound values.The following precautionary caveat pertains only to the test method portions of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Hafnium and Hafnium Alloy Strip, Sheet, and Plate

ICS
77.150.10 (Aluminium products)
CCS
H63
发布
2006
实施

1.1 This specification covers commercial aluminum alloys in ingot form for remelting and molten form for the manufacture of castings. The specific gravity of these alloys does not exceed 3.0 and they are designated as shown in Table 1.Note 1Throughout this specification the use of "ingot" in a general sense includes sow, T-bar, T-ingot, and pig.1.2 Alloy designations are in accordance with ANSI H35.1/H35.1(M). The equivalent Unified Numbering System alloy designations are in accordance with Practice E 527.Note 2Supplementary data pertaining to the alloys covered by this specification when used in the form of castings are given in Specifications B 26/B 26M, B 85, B 108, B 618, and B 686.1.3 For acceptance criteria for inclusion of new aluminum and aluminum alloys in this specification, see Annex A1.1.4 The values stated in inch-pound units are to be regarded as the standard.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Aluminum Alloys in Ingot and Molten Forms for Castings from All Casting Processes

ICS
77.150.10 (Aluminium products)
CCS
H61
发布
2006
实施

empers shown in , and in those standard sizes shown in , as well as in other nonstandard sizes as agreed upon between the purchaser and supplier. Such pipe and tube is intended for use in structural applications such as highway and bridge rails, chain-link fence posts, handrails, sign structures, awning supports, lighting brackets, etc. Structural pipe and tube is not intended for fluid-carrying applications involving pressure.Note 1For drawn seamless tube used in pressure applications see Specifications B 210 and B 210M, for seamless pipe and seamless extruded tube used in pressure applications see Specifications B 241/B 241M, and for drawn tube and pipe for general purpose applications see Specification B 483/B 483M.1.2 Alloy and temper designations are in accordance with ANSI H35.1. The equivalent Unified Numbering System alloy designations are those of preceded by A9, for example, A96061 for alloy 6061 in accordance with Practice E 527.1.3 For acceptance criteria for inclusion of new aluminum and aluminum alloys in this specification, see .1.4 UnitsThe values stated in either inch-pound units or SI units are to be regarded separately as standard. SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the specification.1.4.1 While this standard is a combined SI and inch-pound standard, standard pipe sizes are not applicable to SI units, therefore non-rationalized SI units (soft conversions) are shown for reader convenience. Rationalized [hard converted] SI units are shown in brackets while non-rationalized (soft converted) SI units are shown in parentheses.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Aluminum-Alloy Extruded Structural Pipe and Tube

ICS
77.150.10 (Aluminium products)
CCS
发布
2006
实施

1.1 This specification covers aluminum and aluminum-alloy extruded bar, rod, wire, profile, and tube in the aluminum alloys (Note 0) and tempers shown in . Note 0Throughout this specification, the use of the term alloy in the general sense includes aluminum as well as aluminum alloy.Note 2For rolled or cold-finished bar and rod refer to Specification B 211, for drawn seamless tube used in pressure applications, Specification B 210, for structural pipe and tube, Specification B 429, and for seamless pipe and tube used in pressure applications, Specification B 241/B 241M.Note 3Structural pipe and tube produced in accordance with B 221 is not intended for fluid-carrying applications involving pressure. Refer to either Specification B 210 or B 241/B 241M, as appropriate, for seamless pipe and tube used in fluid-carrying applications involving pressure.1.2 Alloy and temper designations are in accordance with ANSI H35.1. The equivalent Unified Numbering System alloy designations are those of preceded by A9; for example, A91100 for Aluminum 1100 in accordance with Practice E 527.1.3 For acceptance criteria for inclusion of new aluminum and aluminum alloys in this specification, see .1.4 A complete metric companion to B 221 has been developed-B 221M; therefore, no metric equivalents are presented in this specification.

Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes

ICS
77.150.10 (Aluminium products)
CCS
H61
发布
2006
实施

1.1 This specification covers aluminum-alloy permanent mold castings designated as shown in .1.2 This specification is not intended for aluminum-alloy permanent mold castings used in aerospace applications.1.3 Alloy and temper designations are in accordance with ANSI H35.1. The equivalent unified numbering system alloy designations are in accordance with Practice E 527.1.4 For acceptance criteria for inclusion of new aluminum and aluminum alloys and their properties in this specification, see and .1.5 The values stated in inch-pound units are to be regarded as the standard. The SI values given in parentheses are for information only.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Aluminum-Alloy Permanent Mold Castings

ICS
77.150.10 (Aluminium products)
CCS
H61
发布
2006
实施

1.1 This specification covers aluminum-alloy sand castings designated as shown in .1.2 This specification is not intended for aluminum-alloy sand castings used in aerospace applications.1.3 Alloy and temper designations are in accordance with ANSI H35.1 and H35.1M. Unified Numbering System alloy designations are in accordance with Practice E 527.1.4 Unless the order specifies the "M" specification designation, the material shall be furnished to the inch-pound units.1.5 For acceptance criteria for inclusion of new aluminum and aluminum alloys and their properties in this specification, see and .1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Aluminum-Alloy Sand Castings

ICS
77.150.10 (Aluminium products)
CCS
发布
2005
实施

1.1 This specification covers aluminum alloy sheets used in the fabrication of corrugated aluminum pipe intended for use for storm water drainage, underdrains, culverts, and similar uses. The material is furnished corrugated in cut lengths, and uncorrugated in coils and cut lengths. 1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Aluminum Alloy Sheet for Corrugated Aluminum Pipe

ICS
77.150.10 (Aluminium products)
CCS
H61
发布
2005
实施

1.1 This specification covers a rigid wall, two-side expandable shelter constructed of aluminum-faced, nonmetallic honeycomb sandwich panels and meeting the International Organization for Standardization (ISO) cargo container specification in the transport mode. Nominal dimensions when closed (container mode) are: height 8 ft, width 8 ft, and length 20 ft (2.4 by 2.4 by 6.1 m). Approximate dimensions when expanded (shelter mode) are: height 8 ft, width 22 ft, and length 20 ft (2.4 by 6.7 by 6.1 m).1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Shelter, Tactical, Expandable, Two-Side

ICS
77.150.10 (Aluminium products)
CCS
H61
发布
2005
实施

1.1 These digital reference images illustrate the types and degrees of discontinuities that may be found in aluminum-alloy castings. The castings illustrated are in thicknesses of 1/ 4 in. [6.35 mm] and 3/4 in. [19.1mm].1.2 All areas of this standard may be open to agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization. These items should be addressed in the purchase order or the contract.1.3 The values stated in inch-pound units are to be regarded as standard.1.4 These digital reference images are not intended to illustrate the types and degrees of discontinuities found in aluminum-alloy castings when performing film radiography. If performing film radiography of aluminum-alloy castings, refer to Reference Radiographs E 155.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.5 Only licensed copies of the software and images shall be utilized for production inspection. A copy of the ASTM/User license agreement shall be kept on file for audit purposes.Note 1The set of digital reference images consists of 13 digital files, software to load the desired format and specific instructions on the loading process. The 13 reference images illustrate eight grades of severity and contain an image of a step wedge and two line pair gauges. Refer to Practice E 2002 for line pair gauge details.Note 2Reference radiographs applicable to aluminum and magnesium die castings up to 1 in. [25 mm] in thickness are contained in Reference Radiographs E 505.

Standard Digital Reference Images for Inspection of Aluminum Castings

ICS
77.150.10 (Aluminium products)
CCS
H61
发布
2005
实施

1.1 This specification covers a rigid wall, one-side expandable shelter constructed of aluminum-faced, nonmetallic honeycomb sandwich panels, and meeting the International Organization for Standardization (ISO) Cargo Container specification in the transport mode. Nominal dimensions when closed (container mode) are: height 8 ft, width 8 ft, and length 20 ft. (2.4 by 2.4 by 6.1 m) Approximate dimensions, when expanded (shelter mode) are: height 8 ft, width 15 ft, and length 20 ft (2.4 by 4.6 by 6.1 m).1.2 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are for information only.1.3The following precautionary statement pertains to the test method portion only. Section 7, of this specification; This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determines the applicability of regulatory limitations prior to use.

Standard Specification for Shelter, Tactical, Expandable, One-Side

ICS
77.150.10 (Aluminium products)
CCS
H61
发布
2005
实施

1.1 This specification covers aluminum and aluminum-alloy drawn seamless tubes in straight lengths and coils for general purpose and pressure applications in alloys (Note 2), tempers, and thicknesses shown in Table 2. Coiled tubes are generally available only as round tubes with a wall thickness not exceeding 2.00 mm and only in nonheat-treatable alloys.1.2 Alloy and temper designations are in accordance with ANSI H35.1M. The equivalent Unified Numbering System alloy designations are those of Table 1 preceded by A9, for example, A91100 for aluminum 1100 in accordance with Practice E 527.1.3 Preferred metric sizes are in accordance with ANSI B 32.5. Note 18212;See Specification B 483M for aluminum and aluminum-alloy drawn tubes for general purpose applications, Specification B 234M for aluminum-alloy drawn seamless tubes for condensers and heat exchangers, and Specification B 241/B 241M for aluminum-alloy seamless pipe and seamless extruded tube.Note 18212;Throughout this specification use of the term alloyin the general sense includes aluminum as well as aluminum alloy.1.4 This specification is the metric counterpart of Specification B 210.1.5 For acceptance criteria for inclusion of new aluminum and aluminum alloys in this specification, see Annex A2. 1.6 The values stated in SI units are to be regarded as standard. No other units of measure are included in this standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Aluminum and Aluminum-Alloy Drawn Seamless Tubes [Metric]

ICS
77.150.10 (Aluminium products)
CCS
H61
发布
2005
实施

1.1 This specification establishes the requirements for Copper Alloy UNS Nos. C61300 and C61400 aluminum bronze sheet, strip, and rolled bar.1.2 The products made to this specification are commonly used for drawing, forming, stamping, and bending applications and are not intended for electrical applications.Note 1The products produced under this general specification may be used in many applications in which the individual requirements may be too specific to be determined by normal physical or mechanical testing. Therefore, it may be advisable for the purchaser to submit samples or drawings to the manufacturer to be assured that the product furnished is suitable for the intended application.Note 2Refer to Specification B 171/B 171M for plate product. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

Standard Specification for Aluminum Bronze Sheet, Strip, and Rolled Bar

ICS
77.150.10 (Aluminium products)
CCS
发布
2005
实施

The test method was developed for use with high strength aluminum alloys (2XXX and Cu containing 7XXX) that are normally tested in 3.5 weight % NaCl by alternate immersion. However, the concept which uses residual strength as a measure of damage evolution (in this case environmentally-assisted cracking) can, in principle, be applied to any alloy and environmental system. This test method has been developed for research studies of alloys and tempers with improved resistance to SCC. The test results permit different material variants to be compared with a high degree of confidence and with much more precision than the results of pass/fail tests. Thus, it is particularly useful for comparing materials with similar levels of resistance to stress-corrosion cracking. The procedure could be modified for use as a quality assurance tool but this has not been a primary purpose during its development. The exposure periods and conditions that are described in this test method apply specifically to high strength aluminum alloys, but the statistical techniques should be valid for other alloy systems with different exposure conditions. Although this particular procedure was primarily intended for testing products in the short-transverse stressing direction, it is useful for other stressing directions, particularly the long-transverse direction in sheet and thin plate products. Determination of the actual serviceability of a material requires stress-corrosion testing performed in the intended service environment, under conditions relating to the end use, including protective measures such as coatings and inhibitors and is outside the scope of this test method. There is no good way to compare test environments to actual service because most service environments have large inherent variability with respect to a single structure that may experience many different environments or with respect to two identical structures that serve in different locations. Unless a sample can be tested in the actual service environment for the expected life of the component, no conclusive determination can be made about the suitability of a particular material for a particular application. Designers must therefore make judgments on the suitability of particular materials for applications based on knowledge of the material and of the service environment. To avoid service failures, the environment used for preliminary evaluations is often chosen based on a worst case scenario leading to intentional overestimations of corrosion damage.1.1 This test method covers procedures for evaluation of stress corrosion cracking (SCC) resistance by the breaking load test method, a concept which uses residual strength as the measure of damage evolution (in this case environmentally assisted cracking). 1.2 This test method covers specimen type and replication, test environment, stress levels, exposure periods, final strength determination, and statistical analysis of the raw residual strength data. 1.3 The test method was developed for use with heat-treatable aluminum alloys, that is, 2XXX alloys and 7XXX with 1.2 to 3.0 % Cu, and test specimens oriented in the short-transverse direction relative to grain structure (1, 2). However, the residual strength measurements and the statistics used to analyze the data are not specific to heat-treatable aluminum alloys and can be used for other specimen orientations and different types of materials. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Determining Stress-Corrosion Cracking Resistance of Heat-Treatable Aluminum Alloy Products Using Breaking Load Method

ICS
77.150.10 (Aluminium products)
CCS
H25
发布
2005
实施

1.1 This specification covers heat resistant aluminum-zirconium alloy round wire for electrical purposes. There is a family of aluminum-zirconium alloys that are used for heat-resistance (i.e. resist annealing), which differ by zirconium content, tensile strength, electrical conductivity, and maximum use temperature. This standard covers one currently commercially applicable alloy from this family.1.2 The values stated in inch-pound units are standard. The SI equivalents of inch-pound units may be approximate.

Standard Specification for Heat Resistant Aluminum-Zirconium Alloy Wire for Electrical Purposes

ICS
77.150.10 (Aluminium products)
CCS
H61
发布
2005
实施

1.1 This specification covers aluminum and aluminum-alloy extruded bar, rod, wire, profile, and tube in the aluminum alloys (Note 1) and tempers shown in Table 2. 8212;Throughout this specification the use of the term alloy in the general sense includes aluminum as well as aluminum alloy.Note 28212;For rolled or cold-finished bars and rods refer to Specification B 211M, for drawn tube, Specification B 210M, for structural pipe and tube, Specification B 429M, and for seamless pipe and tube, Specification B 241/B 241M. 1.2 Alloy and temper designations are in accordance with ANSI H35.1M. The equivalent Unified Numbering System alloy designations are those of preceded by A9, for example, A91100 for Aluminum 1100 in accordance with Practice E 527.1.3 For acceptance criteria for inclusion of new aluminum and aluminum alloys in this specification, see .1.4 This specification is the metric counterpart of Specification B 221.1.5 The values stated in SI are to be regarded as standard. No other units of measurement are included in this specification.

Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes [Metric]

ICS
77.150.10 (Aluminium products)
CCS
H61
发布
2005
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号