This standard deals with the safety of electrically heated gullies for de-icing the inlet of the drainage system of flat roofs, balconies, and similar structures, their rated voltage being not more than 250 V. As far as practicable, this standard deals with the common hazards presented by appliances which are encountered by all persons in and around the home. However, in general, it does not take into account - the use of appliances by young children or infirm persons without supervision; - playing with the appliance by young children.

Household and similar electrical appliances - Safety - Part 2-83: Particular requirements for heated gullies for roof drainage

ICS
91.060.20
CCS
发布
2003-01-08
实施
2002-12-17

This Standard establishes minimum design requirements for roof drains, including general purpose, gutter and cornice, parapet and promenade, balcony, or deck types, which convey rainwater from the roof area of building structures. It includes definitions, nomenclature, outlet types and connections, dome or grate-free area, top loading classifications, materials and finishes, and accessories.

Roof, Deck, and Balcony Drains

ICS
91.060.20
CCS
Q81;P41
发布
2003-01-01
实施

1.1 This test method provides impact resistance data for the evaluation of prepared roof covering materials. For purposes of this Standard prepared roof covering materials are considered to be small units, sheets or panels designed for installation with multiple layers of such materials installed in overlapping rows normally on inclines exceeding 25 percent. 1.2 The test evaluates the effect of impact from the steel ball at locations on the assembly selected to be most vulnerable, such as (but not limited to) edges, corners, unsupported sections and joints. 1.3 Deleted January 25, 2002. 1.4 This test method does not evaluate the effect of weathering, temperature, aging or similar effects on the impact resistance of prepared roof covering materials. These and other factors, including time, roof slope, roof system configuration and application influence the performance of roofing materials in the field. It is not the objective of this test to address all of these factors.

2/21/2003 (66p)

ICS
91.060.20
CCS
发布
2003-01-01
实施

Covers the wind resistance of sheet roofing, asphalt shingles, formed metal shakes and shingyles, fire-retardent-treated wood shakes and shingles, and other prepared roof covering materials. These materials are intended, when properly installed, to resist damage when subjected to winds in the Beaufort Scale N. 10 range (55-63 mph).

Wind Resistance of Prepared Roof-Covering Materials

ICS
91.060.20
CCS
Q17
发布
2003-01-01
实施

The following items are subject to comments: 1.) Proposed requirements based on comments received to ANSI canvass 2.) Miscellaneous proposed revision

12/1/2003 (10p)

ICS
91.060.20
CCS
发布
2003
实施

Establishes minimum design requirements for roof drains including general purpose, gutter and cornice, parapet and promenade, balcony or deck types, which convey rainwater from the roof area of building structures. It includes definitions, nomenclature outlet types and connections, dome or grate free area, top loading classifications, materials and finishes, and accessories. This standard was listed for public review in the 4/21/2000 issue of Standards Action. It is being resubmitted due to substantive changes to the text.

Roof, Deck, and Balcony Drains

ICS
91.060.20
CCS
P41
发布
2003
实施

1.1 This specification covers concrete tiles intended for the use as roof covering where durability and appearance are required to provide a weather-resistant surface of specified design. 1.2 Tiles are manufactured from portland cement, water, and mineral aggregates with or without the inclusion of other materials. 1.3 Tiles are shaped during manufacturing by molding, pressing, or extrusion. The shaping method can be used to describe the tile. 1.4 Other constituents, such as chemical and mineral admixtures established as suitable for use in concrete, shall conform to ASTM standard specifications where applicable, or shall be shown by tests or experience not to be detrimental to the durability of concrete. 1.5 Tiles are generally planar or undulating rectangular shapes available in a variety of cross-sectional areas profiles, shapes, sizes, surface textures, and colors. Note 1: Concrete roof tiles covered by this specification are made from lightweight or normal weight aggregates, or both. Note 2: When particular features are desired, such as color, surface texture for appearance, or other special features, such properties should be specified by the purchaser. However. the local sellers should be consulted as to the availability of concrete roof tile having a desired feature. 1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Standard Specification for Concrete Roof Tile

ICS
91.060.20
CCS
Q17
发布
2003
实施

To be read in conjunction with BS EN 60335-1:2002

Specification for safety of household and similar electrical appliances - Particular requirements - Heated gullies for roof drainage

ICS
91.060.20
CCS
P20
发布
2002-11-25
实施
2002-11-25

This clause of part 1 is replaced by: This international standard deals with the safety of electrically heated gullies for de-icing the inlet of the drainage system of flat roofs, balconies, and similar structures, their rated voltage being not more than 250 V. As far as is practicable, this standard deals with the common hazards presented by appliances which are encountered by all persons in and around the home. However, in general, it does not take into account

Household and similar electrical appliances - Safety Part 2-83: Particular requirements for heated gullies for roof drainage

ICS
91.060.20
CCS
Q81
发布
2002-11-25
实施
2002-11-25

이 규격은 유리 섬유를 펠트 모양으로 짜서 건조시켜 만든 보강 심재(이하 심재라 한다.)의

Asphalt shingles

ICS
91.060.20
CCS
B70
发布
2002-09-30
实施
2002-09-30

This British Standard specifies the requirements for cast iron rainwater systems for use on buildings. The sizes of the rainwater system extend from DN 50 to DN 150. This standard specifies the requirements for the materials, dimensions, tolerances, mechanical properties, surface condition, primary coatings, jointing methods and marking for the following components of the rainwater system: —rainwater pipes, fittings and components used for assembly or support; —gutters, including half-round, ogee and beaded, fittings and components used for assembly or support.

Cast iron rainwater goods - Specification

ICS
91.060.20
CCS
Q81
发布
2002-09-09
实施
2002-09-09

This British Standard specifies the requirements for cast iron rainwater systems for use on buildings.The sizes of the rainwater system extend from DN 50 to DN 150. This standard specifies the requirements for the materials, dimensions, tolerances, mechanical properties, surface condition, primary coatings, jointing methods and marking for the following components of the rainwater system: - rainwater pipes, fittings and components used for assembly or support; -gutters, including half-round, ogee and beaded, fittings and components used for assembly or support; - gutters, including half-round, ogee and beaded, fittings and components used for assembly or support.

Cast iron rainwater goods - Specification

ICS
91.060.20
CCS
Q73
发布
2002-09-09
实施
2002-09-09

This European Standard specifies requirements for roofing products used for assembly into coverings for pitched roofs, made from copper sheet. The standard establishes general characteristics, definitions, and labelling for the products, together with requirements for the materials from which the products can be manufactured. It is intended to be used either by manufacturers to ensure that their products conform to the requirements or by purchasers to verify that the products conform to the requirements before they are dispatched from the factory. It specifies the requirements for products which enable them to meet all normal servic conditions. Products can

Roofing products from metal sheet - Specification for fully supported roofing products of copper sheet

ICS
91.060.20
CCS
发布
2002-02-08
实施
2001-09-21

This European Standard specifies requirements for roofing products used for assembly into coverings for pitched roofs, made from aluminium sheet with or without additional organic coatings. The standard establishes the general characteristics, definitions and labelling of the products, together with requirements for the materials from which the products can be manufactured. It is intended to be used either by manufacturers to ensure that their products comply with the requirements or by purchasers to verify that the products comply before they are dispatched from the factory. It specifies the requirements for products which enable them to meet all normal se

Roofing products from metal sheet - Specification for fully supported products of aluminium sheet

ICS
91.060.20
CCS
发布
2002-01-10
实施
2001-09-21

1.1 This test method provides impact resistance data for the evaluation of prepared roof covering materials. For purposes of this Standard prepared roof covering materials are considered to be small units, sheets or panels designed for installation with multiple layers of such materials installed in overlapping rows normally on inclines exceeding 25 percent. 1.2 The test evaluates the effect of impact from the steel ball at locations on the assembly selected to be most vulnerable, such as (but not limited to) edges, corners, unsupported sections and joints. 1.3 Deleted January 25, 2002. 1.4 This test method does not evaluate the effect of weathering, temperature, aging or similar effects on the impact resistance of prepared roof covering materials. These and other factors, including time, roof slope, roof system configuration and application influence the performance of roofing materials in the field. It is not the objective of this test to address all of these factors.

1/31/2002 (28p)

ICS
91.060.20
CCS
发布
2002-01-01
实施

Covers the wind resistance of sheet roofing, asphalt shingles, formed metal shakes and shingyles, fire-retardent-treated wood shakes and shingles, and other prepared roof covering materials. These materials are intended, when properly installed, to resist damage when subjected to winds in the Beaufort Scale N. 10 range (55-63 mph)

Wind Resistance of Prepared Roof-Covering Materials

ICS
91.060.20
CCS
Q17
发布
2002
实施

Amdt 1 29 May 2009 (ISBN 0-7337-9096-8)

Household and similar electrical appliances - Safety - Particular requirements for heated gullies for roof drainage (IEC 60335-2-83:2001, IDT)

ICS
91.060.20
CCS
发布
2002
实施

Methods for fire tests of roof coverings

ICS
91.060.20
CCS
发布
2001-12-26
实施

Methods for fire tests of roof coverings

ICS
91.060.20
CCS
发布
2001-12-26
实施

이 규격은 건물 외부 연소에 의한 지붕재의 화재 특성 측정 방법을 규정한다. 가연성 또는

Methods for fire tests of roof coverings

ICS
91.060.20
CCS
Q15
发布
2001-12-26
实施
2001-12-26