共找到 433 条与 天花板、地板、楼梯 相关的标准,共 29 页
1.1 This test method covers the evaluation of ceramic floor tile installation systems, using the Robinson2 -type floor tester. 1.2 This test method is intended solely for evaluating complete ceramic floor tile installation systems for failure under dynamic loads and not for evaluating particular characteristics of ceramic tile, such as abrasion resistance. This test method does not claim to provide meaningful results for other than evaluating complete ceramic floor tile installation systems. 1.3 The values stated in inch-pound units are to be regarded as the standard. The metric (SI) units in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Standard Test Method for Evaluating Ceramic Floor Tile Installation Systems Using the Robinson-Type Floor Tester
This standard applies in addition to DIN EN 14975 to loft ladders, which are supposed to be installed in ceilings with a high thickness and for which additional treads are necressary. This standards applies furthermore to loft ladders with a maximum total load higher than 150 kg.
Loft ladders - Special constructions for ceilings with a high thickness and for an increased maximum total load
Standard Practice for Design, Construction, and Material Requirements for Direct Hung Suspended T-bar Type Ceiling Systems Intended to Receive Gypsum Panel Products in Areas Subject to Earthquake Grou
Standard Specification for Glass-Fiber Reinforced Polyester Wall and Ceiling Panels
Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring
Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions
This draft standard applies in addition to DIN EN 14975 to loft ladders, which are supposed to be installed in ceilings with a high thickness and for which additional treads are necressary. This draft standards applies furthermore to loft ladders with a maximum total load higher than 150 kg.
Loft ladders - Special constructions for ceilings with a high thickness and for an increased maximum total load
1.1 This practice covers the installation requirements of direct hung suspended t-bar type ceiling systems intended to receive gypsum panel products constructed as flat, single level, surrounded on all sides by a wall, bulk head, or soffit braced to the building structure to resist the effects of earthquake ground motions. 1.2 Ceiling assembly shall not be intended to support live loads. 1.3 This standard addresses ceiling systems with dead loads up to 10 lbs/ft2 (48.8 kg/m2 ). 1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.5 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate standard safety and health practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Standard Practice for Design, Construction, and Material Requirements for Direct Hung Suspended T-bar Type Ceiling Systems Intended to Receive Gypsum Panel Products in Areas Subject to Earth
本标准规定了集成吊顶的术语和定义、基本要求、技术要求、检验、试验方法、检验规则、标志、包装、运输和贮存以及质量承诺的内容和要求。 本标准适用于家用和类似用途集成吊顶。
Integrated ceiling
1.1 This specification covers concrete floor tile (CFT) for application as interior and exterior flooring. The units described by this specification are manufactured from cementitious materials, mineral aggregates (normal weight, lightweight, or both), water, and additives that are cast into various textures and shapes, often simulating natural stone, brick, terracotta, saltillo, and others. 1.2 This specification is limited to requirements for the physical attributes for the CFT units. 1.3 The use of results from testing installed CFT units that have been removed from use for determining conformance or nonconformance to the requirements of this specification is beyond the scope of this specification. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Specification for Concrete Floor Tile
Steel flights of steps, stair landings and railings. Specifications
Scope is not provided for this standard
Building construction -- Modular coordination -- Modular floor plane for vertical dimensions
Scope is not provided for this standard
Building construction -- Modular co-ordination -- Stairs and stair openings -- Co-ordinating dimensions
本标准规定了具有太阳能转换功能的阳台护栏术语和定义、分类和标记、材料和部件、要求、试验方法、检验规则、产品标志、随行文件、包装、运输和贮存。 本标准适用于栏板为太阳能光伏组件、太阳能光热组件和太阳能光伏光热一体化组件的阳台护栏。
Solar balcony guardrail
Floor screeds in building construction - Part 1: General requirements, testing and construction