共找到 513 条与 外部污水排放系统 相关的标准,共 35 页
VACUUM SEWERAGE SYSTEMS OUTSIDE BUILDINGS. (EUROPEAN STANDARD EN 1091).
This European Standard is applicable to drain and sewer systems, which operate essentially under gravity, from the point where the sewage leaves a building or roof drainage system, or enters a road gully, to the point where it is discharged into a treatment works or receiving water. Drains and sewers below buildings are included provided that they do not form part of the drainage system of the building. This Part sets out the performance requirements to be taken into account when planning, designing, installing and operating drain and sewer systems that operate essentially under gravity.
Drain and sewer systems outside buildings - Performance requirements
This European Standard is applicable to drain and sewer systems, which operate essentially under gravity, from the point where the sewage leaves a building or roof drainage system, or enters a road gully, to the point where it is discharged into a treatment works or receiving water. Drains and sewers below buildings are included provided that they do not form part of the drainage system of the building. This Part sets out the principles to follow when planning drain and sewer systems that operate essentially under gravity.
Drain and sewer systems outside buildings - Planning
The document specifies the performance requirements of negative pressure driven sewerage systems carrying domestic waste water independent of their material. It also covers additional performance characteristics that are of importance to the specifiers, designers, constructors and operators of vacuum sewerage systems.
Vacuum sewerage systems outside buildings; German version EN 1091:1996
Vitrified clay pipes and fittings and pipe joints for drains and sewers. Part 1 : requirements.
Drain and sewer systems outside buildings. Part 2 : performance requirements.
Drain and sewer systems outside buildings. Part 3 : planning.
This European Standard applies to drain and sewer systems, which operate essentially under gravity, from the point where the sewerage leaves a building or roof drainage system, or enters a road gully, to the point where it is discharged into a treatment works or receiving water. Drains and sewers below buildings are included provided that they do not form part of the drainage system of the building. This Part covers general matters and sets out definitions of terms that relate to the functional requirements of drain and sewer systems outside buildings. These definitions are not intended to be legal definitions.
Drain and sewer systems outside buildings - Generalities and definitions
This Standard specifies the requirements for components for vitrified clay manholes and inspection shafts. These are for use with flexibly jointed vitrified clay pipes and fittings manufactured to EN 295-1 and where appropriate the components are specified to EN 295-1. Where this standard provides for different systems of jointing, different heights, different strength classes and different channels, the specifiers/purchasers may select according to their requirements. NOTE Where reference is made to clauses in EN 295-1:1991, EN 295-2:1991 or EN 295-3:1991 this is clearly stated.
Vitrified clay pipes and fittings and pipe joints for drains and sewers - Requirements for vitrified clay manholes
This Part of this European Standard specifies requirements for flexibly jointed vitrified clay pipes for the construction of pipelines by pipe jacking techniques including micro-tunnelling, pipe-eating, pipe bursting and where appropriate for slip-lining. Where this standard provides for different strength classes the specifiers/purchasers may select according to their requirements.
Vitrified clay pipes and fittings and pipe joints for drains and sewers - Requirements for vitrified clay pipes and joints for pipe jacking
Drain and sewer systems outside buildings. Part 1 : generalities and definitions.
Vitrified clays pipes and fittings and pipe joints for drains and sewers. Part 7 : requirements for vitrified clay pipes and joints for pipe jacking.
Vitrified clay pipes and fittings and pipe joints for drains and sewers. Part 6 : requirements for vitrified clay manholes.
This European Standard specifies the performance requirements of negative pressure driven sewerage systems carrying domestic waste water independent of their material. It also covers additional performance characteristics that are of importance toThe specifiers, designers, constructors and operators of vacuum sewerage systems.
Vacuum Sewerage Systems Outside Buildings
The document lays down brick bases for manholes and inspection chambers for buried drains and sewers. Manhole bases for this document will be in priority employment, if suitable individual manufactury of prefabricated parts for DIN 4034-1 makes necessary disproportionate high expense.#,,#
Prefabricated concrete and reinforced concrete manholes and inspection chambers - Part 10: Brick manhole bases for buried drains and sewers; requirements and testing
This Standard specifies the requirements for special fittings, adaptors and compatible accessories made from vitrified clay and/or other suitable materials for use with vitrified clay pipes and fittings in drainage and sewerage systems. It does not apply to items which are specified in other Parts of EN 295. Any additional requirements for particular items are given in the annexes to this Part of the standard. Where this Standard provides for different systems of jointing dimensions, different lengths and different types of fittings, the specifiers/purchasers may select according to their requirements. NOTE 1. The wide diversity of ranges and numbers of special fittings, adaptors and compatible accessories offered by manufacturers and required by specifiers and purchasers throughout Europe cannot be fully listed within this standard. Manufacturers' product range lists and specifications provide the necessary information. NOTE 2. Where reference is made to clauses in EN 295-1 : 1991 , EN 295-2 : 1991 or EN 295-3 : 1991 this is clearly stated.
Vitrified clay pipes and fittings and pipe joints for drains and sewers - Requirements for special fittings, adaptors and compatible accessories
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Joints for buried non-pressure applications — Test method for the long-term sealing performance of joints with elastomeric seals by estimating the sealing pressure
Vitrified clay pipes and fittings and pipe joints for drains and sewers. Part 4 : requirements for special fittings, adaptors and compatible accessories.
Perforated pipes and compatible fittings for the construction of french drains, land drains and drainage of waste tips.
Vitrified clay pipes and fittings and pipe joints for drains and sewers - Requirements for perforated vitrified clay pipes and fittings
Vitrified clay pipes and fittings and pipe joints for drains and sewers. Part 5 : requirements for perforated vitrified clay pipes and fittings.
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved