The standard contains in addition to DIN EN 509:2000 appliances with a combustion products discharge safety device.

Decorative fuel-effect gas appliances; German version EN 509:1999/A2:2004

ICS
97.100.20
CCS
Q82
发布
2005-03
实施
2005-03-01

Specification for dedicated liquefied petroleum gas appliances - Mobile and portable non-domestic forced convection direct fired air heaters; German version EN 1596:1998 + A1:2004

ICS
97.100.20
CCS
Q82
发布
2005-01
实施
2005-01-01

Details test and examination criteria for gas unit heaters and gas-fired duct furnaces for use with nat, mfd. and mixed gases, LP gases, and LP gas-air mixtures. A unit heater may either be suspended or floor-mounted and may be of the low- or high-static

Gas Unit Heaters and Gas-Fired Duct Furnaces (same as CSA 2.6)

ICS
97.100.20
CCS
Q83
发布
2005
实施

1.1 Scope 1.1.1 This standard applies to newly produced, direct gas-fired industrial air heaters, hereinafter referred to as heaters, whose purpose is to offset building heat loss. Ventilation air to the heater shall be ducted directly from outdoors and the products of combustion generated by the heater are released into the air stream being heated. Heaters covered by this standard are intended for use in industrial and commercial applications. This standard applies to heaters designed for heated discharge air temperature of 160°F (71°C) or less. This standard is intended to cover only complete packaged heaters with integral air moving components, i.e., those which are designed by, cataloged by and built on a repetitive basis by the manufacturer. 1.1.2 Inside air may be introduced before or after the combustion zone. 1.1.3 Outside ventilation air is required to the heater. See 1.22.1-f, 1.22.1-n, and 1.23.2-u. 1.1.4 If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.1.5 All references to psi throughout this standard are to be considered gage pressure unless otherwise specified. 1.1.6 Exhibit A, Electrical Equipment and Wiring. 1.1.7 Exhibit B, List of Reference Standards, contains a list of standards specifically referenced in this Standard, and sources from which they may be obtained.

Recirculating Direct Gas-Fired Industrial Air Heaters

ICS
97.100.20
CCS
发布
2004-12-20
实施

This British Standard specifies the selection, installation and maintenance (see Note 1) of flued. gas-fired, ducted-air heaters of rated input not exceeding 70 kW, based on net calorific value, burning 2nd or 3rd family gases to heat one or more rooms or internal spaces in either domestic premises (see Note 2) or commercial premises. It is applicable to warm air heaters that incorporate a fan to circulate the warm air. It is also applicable to combined air heater/circulator installations and to the servicing and maintenance of heaters that distribute warm air by natural convection (see .Annex A). NOTE 1 For the purposes of this standard, installation includes design, inspection and commissioning. It is recognised that each of these tasks can be performed by the same person. NOTE 2 As well as normally constructed dwellings, domestic premises include any permanently sited leisure accommodation vehicles, residential park homes and permanently moored boats. Particular and additional requirements exist for these categories of premises and can be found in IGE/UP/8 [10]. Neither this standard nor IGE/UP/8 [10] applies to gas installations in towed or motorised caravans.

Installation and maintenance of gas-fired ducted air heaters of rated input not exceeding 70 kW net (2nd and 3rd family gases). Specification

ICS
97.100.20
CCS
P47
发布
2004-12-10
实施
2004-12-10

The change A1 of EN 461 concerns several technical amendments due to need for regulation appearing after ratification of the standard. The standard itself defines the safety characteristics, the test methods and the marking of small non-domestic flueless space heaters, including difussive catalytic combustion heaters, and greenhouse heaters, not exceeding 10 kW rated heat input burning 3rd family gas," referred to in the body of the text as ""appliances"".#",,#

Specifications for dedicated liquefied petroleum gas appliances - Flueless non-domestic space heaters not exceeding 10 kW; German version EN 461:1999 + A1:2004

ICS
97.100.20
CCS
Q83
发布
2004-11
实施
2004-11-01

Specification for dedicated liquefied petroleum gas appliances - Mobile and portable non-domestic forced convection direct fired air heaters.

ICS
97.100.20
CCS
J98
发布
2004-09-01
实施
2004-09-05

This standard defines, for the purpose of type examination, the construction, the safety characteristics, the test methods and the marking of mobile and portable non-domestic forced convection direct fired air heaters with a rated heat input not exceeding 180 kW (Hs) and burning 3rd family gases.

Specification for dedicated liquefied petroleum gas appliances - Mobile and portable non-domestic forced convection direct fired air heaters

ICS
97.100.20
CCS
发布
2004-08-13
实施
2004-06-10

This European Standard defines requirements and test methods concerning, in particular, the construction safety as well as classification and marking of non-domestic flueless space heaters (including greenhouse heaters and diffusive catalytic combustion heaters), having a nominal heat input not exceeding 10 kW (Hs) burning 3rd family gases at nominal operating pressure not exceeding 50 mbar. It covers the following types of appliance: a) Fixed heaters; b) Portable or mobile heaters including those that incorporate a compartment for a transportable refillable liquefied petroleum gas cylinder; c) Heaters intended for use in non domestic areas; d) Heaters inte

Specification for dedicated liquefied petroleum gas appliances - Flueless non-domestic space heaters not exceeding 10 kW

ICS
97.100.20
CCS
发布
2004-08-13
实施
2004-06-10

Specifies the uniform minimum requirements for manufacturers, designers, regulatory authorities, testing laboratories and similar organizations for the safety, performance and use of radiant gas heaters with a gas consumption not exceeding 70 MJ/h for ou

Radiant gas heaters for outdoor and non-residential indoor use

ICS
97.100.20
CCS
发布
2004-08-10
实施

Specification for dedicated liquefied petroleum gas appliances - Flueless non-domestic space heaters not exceeding 10 kW

ICS
97.100.20
CCS
发布
2004-07-15
实施
2004-07-15

Decorative fuel-effect gas appliances

ICS
97.100.20
CCS
发布
2004-07-15
实施
2004-07-15

Specification for dedicated liquefied petroleum gas appliances - Mobile and portable non-domestic forced convection direct fired air heaters

ICS
97.100.20
CCS
发布
2004-07-15
实施
2004-07-15

Scope 1.1.1 This standard applies to newly produced, direct gas-fired industrial air heaters of the nonrecirculating type, hereinafter referred to as heaters, whose purpose is to offset building heat loss. All air to the heater shall be ducted directly from outdoors and the products of combustion generated by the heater are released into the air stream being heated. Heaters covered by this standard are intended for use in industrial and commercial applications. Heaters covered by this standard are not intended for use in any area containing sleeping quarters. The installation shall conform with local codes, or in the absence of local codes, in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code,CSA B149.1. This standard applies to heaters designed for heated discharge air temperature of 160°F (71°C) or less. This standard is intended to cover only complete packaged heaters with integral air moving components, i.e., those which are designed by, cataloged by and built on a repetitive basis by the manufacturer. 1.1.2 If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.1.3 Items unique to the U.S. are shown in Exhibit A. 1.1.4 Items unique to Canada are shown in Exhibit B. 1.1.5 Exhibit C contains a list of standards specifically referenced in this standard, and sources from which these referenced standards may be obtained. 1.1.6 All references to p.s.i. through this standard are to be considered gage pressure unless other wise specified.

Non-Recirculating Direct Gas-Fired Industrial Air Heaters

ICS
97.100.20
CCS
发布
2004-03-01
实施

1.1 Scope 1.1.1 This standard applies to newly produced vented gas-fired space heating appliances (see PartXIV, Definitions), hereinafter referred to as appliance(s), constructed entirely of new, unused parts and materials, and having input ratings up to and including 400,000 Btu per hour. These appliances are: a. For use with natural gas; b. For use with manufactured gas; c. For use with mixed gas; d. For use with liquefied petroleum gases (propane) (also se2.2-e); and e. For use with LP gas-air mixtures. The construction of vented gas-fired space heating appliances for use with the abovementioned gases is covered under Part I. The performance of vented gas-fired space heating appliances for use with the above-mentioned gases is covered under Part II. 1.1.2 This standard applies only to the following appliance types, as defined in Part XIV,Definitions: a. Gravity vented wall furnace; b. Fan type vented wall furnace; c. Fan type vented wall furnace with cooling unit; d. Vented room heater; e. Gravity direct vent wall furnace; f. Fan-type direct vent wall furnace; and g. Floor furnace. 1.1.3 An appliance having a decorative flame which simulates a solid fuel fire, such as coal or wood, must also comply with the applicable construction provisions of the American National Standard/Canadian Standards Association Standard for Vented Gas Fireplaces, ANSI Z21.50 . CSA 2.22. [See sections 1.2.17 (General Instruction and Assembly), 1.2.18, 1.2.19,1.4 (Evaluation of Combustion/Venting Side Sealing Materials), 1.5,(Glass Fronts), 1.21.7(Vent/Air Intake Pipes), 1.21.8, 1.28.2-g (Instructions), 1.28.3, 1.28.4 and 1.29.2-o(Markings). 1.1.4 This standard covers the thermal efficiency and related markings of only those appliances whose efficiencies are not regulated in the U.S.A. by the Energy Policy and Conservation Act of 1975 and the National Energy Conservation Policy Act of 1978* or covered in Canada by Exhibit B, Items Unique to Canada. 1.1.5 If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.1.6 All references to psi throughout this standard are to be considered gage pressures unless otherwise specified. 1.1.7 All vented gas-fired space heating appliances shall conform with the applicable requirements under Part I and Part II. In addition, for requirements specific to product type also see: a. Vented Room Heaters - Construction, Part III Vented Room Heaters - Performance, Part IV; b. Direct Vent Wall Furnaces - Construction, Part V Direct Vent Wall Furnaces - Performance, Part VI; c. Gravity and Fan Type Wall Furnaces - Construction, Part VII Gravity and Fan Type Wall Furnaces - Performance, Part VIII; and d. Floor Furnaces - Construction, Part IX Floor Furnaces - Performance, Part X. 1.1.8 Exhibit A, Items Unique to the United States, contains provisions that are unique to the United States. 1.1.9 Exhibit B, Items Unique to Canada, contains provisions that are unique to Canada. 1.1.10 Special construction provisions applicable to vented space heating appliances designed for use with an optional design-certified conversion kit are outlined under Exhibit J, (Optional) Provisions for Listed Gas Appliance Conversion Kits. 1.1.11 Exhibit K, List of Reference Standards, contains a list of standards specifically referenced in this standard, and sources from which these reference standards may be obtained.

Vented Gas-Fired Space Heating Appliances

ICS
97.100.20
CCS
发布
2004-02-01
实施

Details test and examination criteria for gas unit heaters and gas-fired duct furnaces for use with nat, mfd. and mixed gases, LP gases, and LP gas-air mixtures. A unit heater may either be suspended or floor-mounted and may be of the low- or high-static pressure type. Duct furnaces are normally installed in distribution ducts of air conditioning systems to supply warm air for heating and depended for air circulation on a blower not furnished as a part of the furnace.

Gas Unit Heaters and Gas-Fired Duct Furnaces

ICS
97.100.20
CCS
Q83
发布
2004
实施

The certification program includes only Heat Pump Pool Heaters that are electrically driven, mechanical compression type systems as defined in the standard.

Performance Rating of Heat Pump Pool Heaters

ICS
97.100.20
CCS
Q82
发布
2004
实施

Open fronted gas-fired independent space heaters

ICS
97.100.20
CCS
发布
2003-12-31
实施
2003-12-31

This European Standard specifies the requirements and test methods for the construction, safety, and marking of decorative fuel effect gas appliances not exceeding a nominal heat input of 20 kW, (based on the net calorific value), thereafter referred to as appliances. This standard is applicable to appliances that are designed to simulate a solid fuel fire and incorporate a natural draught burner with or without an ignition burner. The appliances are for decorative purposes only and are not heating appliances.

Decorative fuel-effect gas appliances

ICS
97.100.20
CCS
发布
2003-11-07
实施
2003-09-30

The document is valid in addition to DIN EN 509:2000 - Decorative fuel-effect appliances. Requirements and testing form oxides of nitrogen were added.

Decorative fuel-effect gas appliances; Amendment A1; German version EN 509:1999/A1:2003

ICS
97.100.20
CCS
Q82
发布
2003-10
实施
2003-10-01