97.100.20 气体加热器 标准查询与下载



共找到 330 条与 气体加热器 相关的标准,共 22

Domestic gas-fired forced convention air heaters for space heating not exceeding a net heat input of 70kW,without a fan to assist transportation of combustion air and/or combustion products

ICS
97.100.20
CCS
发布
2001-01
实施
2001-01

Direct gas-fired hot air blowers for use in greenhouses and supplementary non-domestic space heating.

ICS
97.100.20
CCS
J98
发布
2000-11-01
实施
2000-11-20

1.1 Scope 1.1.1 This Standard applies to newly produced gas-fired unvented room heaters and gas-fired unvented decorative room heaters for connection to the house fuel supply system (see Part IV, Definitions), hereinafter referred to as room heaters or appliances, constructed entirely of new, unused parts and materials, having input ratings up to and including 40,000 Btu per hour (11 723 W) except: 1. Unvented room heaters suitable for installation in bedrooms shall have input ratings of 10,00 Btu per hour (2 931 W) or less; 2. Unvented room heaters suitable for installation in bathrooms shall have input ratings of 6,000 Btu (1 758 W) or less. Unvented room heaters are: a. For sale with natural gas; b. For use with manufactured gas; c. For use with mixed gas; d. For use with liquefied petroleum gases; e. For use with LP gas-air mixtures; and f. For manufactured (mobile) home aftermarket installation for use with natural gas only or for use with liquefied petroleum gases only. Unvented room heaters for installation in bathrooms shall be wall-mounted. Unvented room heaters for installation in bedrooms shall be wall mounted or for installation in solid-fuel burning fireplaces. The construction of unvented room heaters for use with the above-mentioned gases is covered under part I. The performance of unvented room heaters for use with the above gases is covered under part II. 1.1.2 Special construction provisions applicable to room heaters for manufactured (mobile) home aftermarket installation are outlined under 1.1.1-f, 1.19.4-t and 1.20.2-i. 1.1.3 If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification 1.1.4 All references to psi throughout this standard are to be considered gage pressure unless otherwise specified. 1.1.5 Exhibit D, List of Reference Standards, contains a list of standards referenced in this standard, and sources from which these reference standards may be obtained.

Gas-Fired Room Heaters - Volume II, Unvented Room Heaters

ICS
97.100.20
CCS
发布
2000-11-01
实施

Domesitic and non-domestic gas-fired air heaters Suplementary requirements for condensing air heaters

ICS
97.100.20
CCS
发布
2000-11
实施
2000-11

A presente Norma Europeia define os requisitos e os métodos de ensaio relativos à seguran?a e ao rendimento dos geradores de ar quente de convec??o for?ada e de aquecimento n?o doméstico directo que utilizam sistemas de comando totalmente automáticos, a seguir designados por "aparelhos". Esta Norma Europeia aplica-se aos aparelhos dos tipos A2 e A3 cujo caudal térmico é igual ou inferior a 300 kW equipados com queimadores integrados, a serem utilizados que n?o em instala??es domésticas. Também se aplica aparelhos destinados a instala??o exterior. A alimenta??o do ar quente pode ser feita através de condutas. Esta Norma Europeia n?o contém todos os requisitos necessários aos : - aparelhos destinados a uso doméstico; - aparelhos de convec??o for?ada portáteis ou móveis; - aparelhos equipados com supressores de gás; - aparelhos equipados com sistema de regula??o da mistura ar/gás; - aparelhos que incorporem um queimador principal com mais de uma sec??o sob um mesmo comando de queimador, das quais uma ou mais podem ser extintas enquanto outra sec??o se mantém em funcionamento. Esta Norma Europeia é aplicável a aparelhos destinados a ser submetidos a ensaios de tipo. NOTA: Poderá ser necessário reexaminar os requisitos para os aparelhos n?o sujeitos aos ensaios de tipo.

Non-domestic direct gas-fires forced convection air heaters for space heating not exceeding a net heat input of 300kW

ICS
97.100.20
CCS
发布
2000-10
实施
2000-10

A presente Norma Europeia define os requisitos e os métodos de ensaio relativos à seguran?a e ao rendimento dos geradores de ar quente para usos n?o domésticos que utilizam combustíveis gasosos e de caudal térmico, referido ao poder calorífico inferior, inferior ou igual a 300kW, munidos de queimador(es) atmosférico(s) e sem ventilador para alimenta??o do ar comburente e/ou evacua??o dos produtos da combust?o, a seguir designados por "aparelhos". Esta Norma Europeia aplica-se aos aparelhos dos tipos Bn, Cn e C3i destinados a ser utilizados em locais n?o domésticos. A distribui??o do ar quente pode ser feita através de condutas ou directamente nos espa?os a aquecer. Esta Norma Europeia n?o contém todos os requisitos necessários aos : Aparelhos destinados a ser utilizados num apartamento residencial individual; -aparelhos com condensa??o; -aparelhos destinados a ser instalados no exterior; -de climatiza??o com dupla fun??o (aquecimento e arrefecimento do ar); -aparelhos onde o ar é aquecido por um fluido intermédio; -aparelhos com queimadores de ventila??o; -aparelhos comportando meios de regula??o manuais ou automáticos de alimenta??o de ar comburente ou de evacua??o dos produtos da combust?o (incluindo as borboleta das chaminés); -aparelhos de convec??o for?ada portáteis ou móveis; -aparelhos munidos de vários módulos de aquecimento associados a um único dispositivo anti-retorno de tiragem; -aparelhos munidos de várias cúpulas de evacua??o. Esta Norma Europeia apenas diz respeito aos ensaios de tipo. NOTA: Requisitos para aparelhos aos quais n?o v?o ser efectuados ensaios de tipo deviam ser sujeitos a estudos suplementares.

Domestic gas-fired force convection air heaters for space heating not exceeding a net heat input of 300kW,without a fan to assist transportation of combustion air and/or combustion products

ICS
97.100.20
CCS
发布
2000-10
实施
2000-10

This European Standard specifies the requirements and test methods for the safety of direct gas-fired hot air blowers for greenhouses, agriculturalized or supplementary space heating, hereinafter called "appliances". "Supplementary" in this standard means to make up a deficiency, i.e. for the temporary heating of spaces intended for agricultural or commercial use: - workshops, sheds, stables, poultry houses, barns, cattle pens, etc.; - factories, workshops, warehouses, storage sheds, mills, hangers, drying of buildings, temporary site accommodation, etc. This standard applies to appliances of type A3 with heat input 180 kW or less, based on the net calorific value, fitted with integral burners, including appliances designed for outdoor installation. Provision of the heated air will be directly into the heated space. This standard does not apply to: - appliances intended for use in residential dwellings; - appliances fitted with gas boosters; - appliances fitted with air/gas ratio controls; - appliances fitted with forced draught package burners; - appliances which incorporate a main burner having more than one section under a common burner control, of which one or more sections may be extinguished whilst another section remains in operation; - mobile and transportable dedicated LPG appliances. This standard does not cover the requirements relating to third family gas cylinders, their regulators and their connection. This European Standard is applicable to appliances which are intended to be type tested.

Direct gas-fired hot air blowers for use in greenhouses and supplementary non-domestic space heating

ICS
97.100.20
CCS
Q83
发布
2000-08-15
实施
2000-08-15

1.1この規格は,都市ガス又は液化石油ガスを燃料(以下,ガスという。)とするガスエンジン(以下,エンジンという。)で蒸気圧縮冷凍サイクルの圧縮機を駆動するヒートポンプ式の冷暖房機(以下,ガスヒートポンプという。)のうち,分離形で凝縮器(蒸発器)が空冷(空気熱源)式のダクト接続形ガスヒートポンプで,定格冷房能力ガて28 kW以下のものについて,各種の定格性能を決定するための標準条件及び試験方法について規定する。この規格は,単一冷凍サイクルでーつの凝縮器とーつの蒸発器をもつシステムにだけ適用する。

Gas engine driven heat pump air conditioners -- Part 3: Ducted gas engine driven heat pump air conditioners -- Testing and rating for performance

ICS
97.100.20
CCS
P48
发布
2000-07-20
实施

Gas engine driven heat pump air conditioners -- Part 1: General requirements

ICS
97.100.20
CCS
P48
发布
2000-07-20
实施

1.1この規格は,都市ガス又は液化石油ガス(以下,ガスという。)を燃料とするガスエンジン(以下,エンジンという。)で蒸気圧縮冷凍サイクルの圧縮機を駆動するヒートポンプ式の冷暖房機(以下,ガスヒートポンプという。)のうち,分離形で凝縮器(蒸発器)が空冷(空気熱源)式の直吹き形ガスヒートポンプであって,定格冷房能力が28 kW以下のものについて,各種の定格性能を決定するための標準条件及び試験方法について規定する。この規格は,単一冷凍サイクルでーつの凝縮器とーつの蒸発器をもつシステムにだけ適用する。

Gas engine driven heat pump air conditioners -- Part 2: Non-ducted gas engine driven heat pump air conditioners -- Testing and rating for performance

ICS
97.100.20
CCS
P48
发布
2000-07-20
实施

1.1 Scope 1.1.1 This standard applies to newly produced, direct gas-fired industrial air heaters, hereinafter referred to as heaters, whose purpose is to offset building heat loss. Ventilation air to the heater shall be ducted directly from outdoors and the products of combustion generated by the heater are released into the air stream being heated. Heaters covered by this standard are intended for use in industrial and commercial applications. This standard applies to heaters designed for heated discharge air temperature of 160°F (71°C). This standard is intended to cover only complete packaged heaters with integral air moving components, i.e., those which are de signed by, cataloged by and built on a repetitive basis by the manufacturer. 1.1.2 Inside air may be introduced before or after the combustion zone. 1.1.3 Outside ventilation air is required to the heater. See 1.22-f, 1.22-n, and 1.23.2-u. 1.1.4 If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.1.5 All references to psi throughout this standard are to be considered gage pressure unless otherwise specified. 1.1.6 Exhibit A, Electrical Equipment and Wiring, formerly 1.18. 1.1.7 Exhibit B, List of Reference Standards, contains a list of standards specifically referenced in this Standard, and sources from which they may be obtained.

Recirculating Direct Gas-Fired Industrial Air Heaters

ICS
97.100.20
CCS
发布
2000-06-22
实施

This European Standard specifies the requirements and test methods forThe safety of direct gas-fln,d hot airblowers for greenhouses, agriculturalized or supplementary space heating, hereinafter called "appliances".

Direct Gas-Fired Hot Air Blowers for Use in Greenhouses and Supplementary Non-Domestic Space Heating

ICS
97.100.20
CCS
发布
2000-06-01
实施

This European Standard specifies the requirements and test methods for the construction, safety, and marking of decorative fuel effect gas appliances not exceeding a nominal heat input of 20 kW, (based on the net calorific value), thereafter referred to as appliances. This standard is applicable to appliances that are designed to simulate a solid fuel fire and incorporate a natural draught burner with or without an ignition burner. The appliances are for decorative purposes only and are not heating appliances.

Decorative fuel-effect gas appliances

ICS
97.100.20
CCS
发布
2000-04-07
实施
2000-02-21

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead luminous radiant heaters for environmental comfort, incorporating an atmospheric burner system referred to in the body of the text as "appliances". This European Standard is applicable to Type A1 and Type B11 appliances only (see 4.3). This European Standard is not applicable to: appliances designed for use in domestic dwellings; outdoor appliances; appliances of heat input in excess of 120 kW (based on the net calorific value of the appropriate reference gas); appliances having fully pre-mixed gas and air burners in which: either the gas and all the combustion air are brought together just before the level of the combustion zone; or the pre-mixing of the gas and all combustion air is carried out in a part of the burner upstream of the combustion zone; appliances in which the supply of combustion air and/or the removal of the products of combustion is achieved by integral mechanical means. This standard is applicable to appliances which are intended to be type tested. Requirements for appliances which are not intended to be type tested would need to be subject to further consideration. Requirements concerning the rational use of energy have not been included in this European Standard.

Non-domestic gas-fired overhead luminous radiant heaters - Safety

ICS
97.100.20
CCS
Q83
发布
2000-03-15
实施
2000-03-15

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead radiant tube heaters incorporated into a multi-burner system (called system F and referred to in the body of the text as the "system") with each burner unit under the control of an automatic burner control system. This standard is applicable to type B22x and type B23x systems (see 4.3) intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means. This standard is not applicable to: — systems designed for use in domestic dwellings; — outdoor systems; — systems in which the heat input of an individual burner unit exceeds 120 kW (based on the net calorific value of the appropriate reference test gas); — systems having a draught diverter incorporated between the exhaust fan and the flue duct; — systems having fully pre-mixed gas and air burners in which: — either the gas and all the combustion air are brought together just before the level of the combustion zone; — or the pre-mixing of the gas and all combustion air is carried out in a part of the burner upstream of the combustion zone. This European Standard is applicable to systems which are intended to be type tested. Requirements for systems which are not intended to be type tested would need to be subject to further consideration. Requirements concerning the rational use of energy have not been included in this European Standard.

Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - System F, safety

ICS
97.100.20
CCS
Q83
发布
2000-02-15
实施
2000-02-15

This European Standard specifies the requirements and test methods for the construction, safety, and marking of decorative fuel effect gas appliances not exceeding a nominal heat input of 20 kW, (based on the net calorific value), thereafter referred to as appliances. This standard is applicable to appliances that are designed to simulate a solid fuel fire and incorporate a natural draught burner with or without an ignition burner. The appliances are for decorative purposes only and are not heating appliances. This standard is applicable to type BAS, as described in 4.2.2, decorative fuel effect gas appliances that are designed to be installed within a non-combustible builder's opening or a non-combustible fireplace recess. In addition, this standard is applicable to decorative fuel-effect gas appliances that are designed to be installed under a non-combustible canopy which may be independent or integral with a flue box, for which additional requirements are specified in annex C. This standard is not applicable to: - catalytic combustion appliances; - appliances in which the supply of combustion air and/or the evacuation of products of combustion is achieved by mechanical means. This standard is only applicable to appliances which are intended to be type tested. Matters related to quality assurance systems, tests during production and to certificates of conformity of auxiliary devices are not dealt with by this standard. Requirements concerning the rational use of energy have not been included in this European Standard because the appliances are for decorative purposes.

Decorative fuel-effect gas appliances

ICS
97.100.20
CCS
Q83
发布
2000-02-15
实施
2000-02-15

This European Standard defines, for the purpose of type examination, the requirements, the test methods and the marking of non-domestic flueless space heaters (including greenhouse heaters and diffusive catalytic combustion heaters), having a nominal heat input not exceeding 10 kW (Hs) burning 3rd family gases at nominal operating pressure not exceeding 50 mbar.

Specification for dedicated liquefied petroleum gas appliances - Flueless non-domestic space heaters not exceeding 10 kW

ICS
97.100.20
CCS
发布
2000-02-08
实施
1999-11-16

Decorative fuel-effect gas appliances; German version EN 509:1999

ICS
97.100.20
CCS
Q82
发布
2000-02
实施
1999-02-01

This standard applies to water-cooled singleeffect steam and hot water operated water chilling units, water-cooled double-effect steam and hot water operated water chilling units, and double-effect Direct-Fired (natural gas, oil, LP gas) water chilling/heating units. Water is the refrigerant and LiBr (lithium bromide) the absorbent. See definitions in Section 3.

Absorption Water Chilling and Water Heating Packages

ICS
97.100.20
CCS
Q82
发布
2000-01-01
实施

Details test and examination criteria for construction heaters for use with natural and liquefied petroleum gases. A construction heater is primarily intended for temporary use in heating buildings or structures under construction, alteration or repair.

American National Standard/CSA Standard for Gas Fired Construction Heaters (same as CSA 2.14)

ICS
97.100.20
CCS
Q83
发布
2000
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号