97.100.20 气体加热器 标准查询与下载



共找到 330 条与 气体加热器 相关的标准,共 22

1.1 SCOPE 1.1.1 This standard applies to newly produced vented gas-fired space heating appliances (see Part XIV, Definitions), hereinafter referred to as appliance(s), constructed entirely of new, unused parts and materials: a. For use with natural gas; b. For use with manufactured gas; c. For use with mixed gas; d. For use with liquefied petroleum gases (propane) (also see 2.2-e); and e. For use with LP gas-air mixtures. The construction of vented gas-fired space heating appliances for use with the above-mentioned gases is covered under Part I. The performance of vented gas-fired space heating appliances for use with the above-mentioned gases is covered under Part II. 1.1.2 This standard applies only to the following appliance types, as defined in Part XIV, Definitions: a. Gravity vented wall furnace; b. Fan type vented wall furnace; c. Fan type vented wall furnace with cooling unit; d. Vented room heater; e. Gravity direct vent wall furnace; f. Fan-type direct vent wall furnace; and g. Floor furnace. 1.1.3 An appliance having a decorative flame which simulates a solid fuel fire, such as coal or wood, must also comply with the applicable construction provisions of the Standard for Vented Gas Fireplaces, ANSi Z21.50 ·CGA 2.22. (See sections, 1.2.17, 1.2.18, 1.2.19, 1.4 (Glass Fronts), 1.19.7, 1.19.8, 1.26.2-g, 1.26.3, 1.26.4, and 1.27.2-n.) 1.1.4 This standard covers the thermal efficiency and related markings of only those appliances whose efficiencies are not regulated in the U.S.A. by the Energy Policy and Conservation Act of 1975 and the National Energy Conservation Policy Act of 1978* or covered in Canada by Exhibit B, Items Unique to Canada. 1.1.5 If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.1.6 All references to psi throughout this standard are to be considered gage pressures unless otherwise specified. 1.1.7 All vented gas-fired space heating appliances shall conform with the applicable requirements under Part I and Part II. In addition, for requirements specific to product type also see: a. Vented Room Heaters - Construction, Part IIi Vented Room Heaters - Performance, Part IV; b. Direct Vent Wall Furnaces - Construction, Part v Direct Vent Wall Furnaces - Performance, Part VI; c. Gravity and Fan Type Wall Furnaces - Construction, Part VIi Gravity and Fan Type Wall Furnaces - Performance, Part VIII; and d. Floor Furnaces - Construction, Part Ix Floor Furnaces - Performance, Part X. 1.1.8 Exhibit A, Items Unique to the United States, contains provisions that are unique to the United States. 1.1.9 Exhibit B, Items Unique to Canada, contains provisions that are unique to Canada. 1.1.10 Special construction provisions applicable to vented space heating appliances designed for use with an optional design-certified conversion kit are outlined under Exhibit J, (Optional) Provisions for Listed Gas Appliance Conversion Kits. 1.1.11 Exhibit K, List of Reference Standards, contains a list of standards specifically referenced in this standard, and sources from which these reference standards may be obtained. * At the time of this printing, the above acts regulate the thermal efficiency (heating capacity) of vented appliances. For information, contact the U.S. Department of Energy, Conservation and Solar Applications, Consumer Products Efficiency Branch, 20 Massachusetts Avenue, N.W., Washington, DC 20545.

Vented Gas-Fired Space Heating Appliances

ICS
97.100.20
CCS
发布
1998-03-31
实施

Single burner gas fired overhead radiant tube heaters and non-domestic gas-fired overhead luminous radiant heaters. Requirements and test methods for establishing the rational use of energy. Radiometric method C

ICS
97.100.20
CCS
Q82
发布
1997-12-15
实施
1997-12-15

Single burner gas fired overhead radiant tube heaters and non-domestic gas-fired overhead luminous radiant heaters. Requirements and test methods for establishing the rational use of energy. Radiometric method B

ICS
97.100.20
CCS
Q82
发布
1997-06-15
实施
1997-06-15

Standard for Gas-Fired Unvented Catalytic Room Heaters for Use with Liquefied Petroleum (LP) Gases

ICS
97.100.20
CCS
Q83
发布
1997
实施

Specification for dedicated liquefied petroleum gas appliances. Domestic flueless space heaters (including diffusive catalytic combustion heaters).

ICS
97.100.20
CCS
Q82
发布
1996-07-01
实施
1996-07-20

この規格は,液化石油ガス又は都市ガス(以下,ガスという。)を燃料とする表示ガス消費量が,19kW以下の主として一般家庭用のガス暖房機器(以下,機器という。)について規定する。

Gas burning space heaters for domestic use

ICS
97.100.20
CCS
Q82
发布
1996-03-01
实施

Glazed ceramic wall tiles, Specification and test method

ICS
97.100.20
CCS
发布
1996
实施

Details test and examination criteria for direct gas-fired circulating heaters primarily intended for permanent installation in agricultural animal confinement buildings for use with natural, manufactured and mixed gases, liquefied petroleum gases and LP gas-air mixtures.

ANSI/IAS LC 2, Direct Gas-Fired Circulating Heaters for Agricultural Animal Confinement Buildings

ICS
97.100.20
CCS
B92
发布
1996
实施

This is a searchable PDF. 1.1 Scope 1.1.1 This standard applies to newly produced unvented catalytic room heaters (see Part IV, Definitions), hereinafter referred to as heaters, constructed entirely of new, unused parts and materials, having input ratings up to and including 40,000 Btu per hour (11 723 W) for use with liquefied petroleum (LP) gases. The construction of unvented catalytic room heaters for use with LP gase s is covered under Part I. The performance of unvented catalytic room heaters for use with LP gases is covered under Part II. 1.1.2 If a value for measurement as given in this standard is f ollowed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.1.3 All references to psi throughout this standard are to be considered gage pressure unless otherwise specified. 1.1.4 Exhibit C contains a list of standards specifically referenced in this standard, and sources from which these reference standards may be obtained.

Gas-Fired Unvented Catalytic Room Heaters for Use With Liquefied Petroleum (LP) Gases

ICS
97.100.20
CCS
发布
1994-12-05
实施

This standard is concerned with the methods of test for gas fired domestic radiant type portable heaters for use with liquefied petroleum gases (LPG).

METHODS OF TEST FOR GAS FIRED DOMESTIC RADIANT TYPE PORTABLE HEATERS

ICS
97.100.20
CCS
发布
1994-11-16
实施

Independent gas-fired convection heaters with a natural draught burner and a permanent pilot.

ICS
97.100.20
CCS
Q83
发布
1994-06-01
实施
1994-06-20

Details test and examination criteria for unvented catalytic room heaters having input ratings up to and including 40,000 Btu per hour (11 723 W) for use with liquefied petroleum (LP) gases.

Gas-Fired Unvented Catalytic Room Heaters for Use with Liquefied Petroleum (LP) Gases

ICS
97.100.20
CCS
J96
发布
1994
实施

Details test and examination criteria for infrared heaters for use with natural, manufactured and mixed gases, liquefied petroleum gases, and LP gas-air mixtures. These heaters are intended for the heating of outdoor spaces or nonresidential indoor spaces and are intended for location where flammable gases or vapors are not generally present.

Gas-Fired Infrared Heaters

ICS
97.100.20
CCS
Q83
发布
1992
实施

Sauna-heating-appliances with atmospheric burners

ICS
97.100.20
CCS
Y63
发布
1991-05
实施
1991-05-01

Direct gas-fired door heaters; Addenda

ICS
97.100.20
CCS
Q82
发布
1991
实施

Thermal efficiency requirements and associated methods of test for appliances of rated heat input not exceeding 60 kW combined with a circulator of rated heat input not exceeding 8 kW and burning 1st, 2nd and 3rd family gases.

Thermal performance of domestic gas appliances - Specification for thermal performance of combined appliances: fanned-circulation ducted-air heater/circulator

ICS
97.100.20
CCS
Q82
发布
1990-06-30
实施
1990-06-30

This British Standard gives detailed requirements, including safety and performance requirements and methods of test, for direct gas fired forced convection air heaters having heat inputs up to 2 MW, intended for industrial and commercial applications. Appliances covered by this standard are not intended for installation in domestic dwellings. The scope of this standard includes direct gas fired forced convection air heaters for use both with and without ducting, and intended primarily for space heating applications. It therefore includes air heaters designed to provide make-up air, door curtain heaters, spray booth heaters, portable air heaters and direct fired air heaters capable of providing full space heating. This standard specifies the requirements for direct gas fired forced convection air heaters designed for permanent outdoor installation. It also specifies the requirements for transportable direct gas fired forced convection air heaters. This standard applies to appliances designed to operate on normal low pressure district supplies of 2nd family gas. For appliances fitted with gas boosters, additional requirements may apply. NOTE. The titles of the publications referred to in this standard are listed on the inside back cover.

Specification for direct gas-fired forced convection air heaters with rated heat inputs up to 2 MW for industrial and commercial space heating: safety and performance requirements (excluding electrical requirement) (2nd family gases)

ICS
97.100.20
CCS
Q83
发布
1990-03-30
实施
1990-03-30

Specification for indirect gas fired forced convection air heaters with rated heat inputs up to 2 MW for industrial and commercial space heating: safety and performance requirements (excluding electrical requirements (2nd family gases)

ICS
97.100.20
CCS
Q83
发布
1990-02-28
实施
1990-02-28

Safety requirements and associated methods of test for heaters either combined with, or designed to be fitted with, circulators. Covers appliances burning 1st, 2nd and 3rd family gases of rated heat inputs of the air heater and circulator not exceeding 60 kW and 8 kW, respectively.

Safety of domestic gas appliances - Specification for combined appliances: fanned-circulation ducted-air heaters/circulators

ICS
97.100.20
CCS
Q82;Q83
发布
1989-10-31
实施
1989-10-31

Gas appliances; radiant heaters with fan-assisted burners for heating

ICS
97.100.20
CCS
Q82
发布
1988-12
实施
1988-12-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号