Flued oil stoves with vaporizing burners

ICS
97.100.40
CCS
发布
2007-09-17
实施
2007-09-17

EN 1:1998/A1 covers all points to fulfil the requirements of mandate M/129 under the CPD given from the EC to CEN.

Flued oil stoves with vaporizing burners

ICS
97.100.40
CCS
发布
2007-07-30
实施
2007-07-30

Heating boilers - Special requirements for oil fired room sealed units up to 70 kW

ICS
97.100.40
CCS
发布
2007-05-31
实施
2007-05-31

JIS S 2019:2002を,次のように改正する。

Open type natural ventilating oil burning space heaters (Amendment 1)

ICS
97.100.40
CCS
Q83
发布
2007-05-20
实施

JIS S 2039:2002を,次のように改正する。

Semi closed type oil burning space heaters (Amendment 1)

ICS
97.100.40
CCS
Q83
发布
2007-05-20
实施

JIS S 2036:2002を,次のように改正する。

Open type forced ventilating oil burning space heaters (Amendment 1)

ICS
97.100.40
CCS
Q83
发布
2007-05-20
实施

Heating boilers - Condensing heating boilers for fuel oil

ICS
97.100.40
CCS
发布
2007-05-15
实施
2007-05-15

Heating boilers - Condensing heating boilers for fuel oil.

ICS
97.100.40
CCS
J98
发布
2007-05-01
实施
2007-05-20

This European Standard applies to type Cxs central heating boilers as specified in 4.1, equipped with atomizing oil burners: — type C_13, type C_33 and type C_53 boilers, including their combustion air supply and combustion products evacuation ducts and their terminals; — type C_43 boilers including their connection ducts but without the chimney which is erected as a shared duct system and which is part of the building; — type Ce3 boilers, including the connecting piece as specified in 3.7, if not integrated into the boiler; — type Cg3 boilers, including their connection ducts but without the chimney which is part of the building; — that have a nominal useful heat output below or equal to 70 kW; — where the temperature of the water does not exceed 100 °C during normal operation; — where the maximum water-side operating pressure does not exceed 8 bar. This European Standard is intended to establish specific requirements and test methods for type C atomizing oil burning central heating boilers with respect to construction, safety, fitness for purpose, rational use of energy, classification and marking. This European Standard covers only standard tests. For boilers that produce domestic hot water by a drum or a heat exchanger, integrated or juxtaposed, (by accumulation of instant production), this standard only applies to hot water reheating system components that are not subject to operating conditions applicable to the boiler heating system. This European Standard covers units consisting of boilers equipped with burners that meet the requirements of EN 267, with the following exceptions: — maximum NO and CO emission values, estimated for boilers according to the classes defined in EN 303-2; — air factor value, defined by the manufacturer and stated in the boiler's technical specifications; — marking and/or burner data plate which may provide information for the boiler data plate; — installation recommendations for installing the burner on the boiler included in the boiler operating instructions. This European Standard modifies EN 303-1, EN 303-2, EN 304 and specifies supplementary requirements only for room sealed operations.

Heating boilers - Special requirements for oil fired room sealed units up to 70 kW; English version of DIN EN 15035:2007-05

ICS
97.100.40
CCS
J98
发布
2007-05
实施

この規格は,灯油を燃料とし,燃料消費量が,2200g/h以下の密閉式石油ストープ(以下,ストーブという。)について規定する。

Closed type oil burning space heaters

ICS
97.100.40
CCS
Q83
发布
2007-03-20
实施

Heating boilers - Special requirements for oil fired room sealed units up to 70 kW

ICS
97.100.40
CCS
发布
2007-01-31
实施
2007-01-31

This European Standard applies to type CX3 central heating boilers as specified in 4.1, equipped with atomizing oil burners:  type C13, type C33, and type C53 boilers, including their combustion air supply and combustion products evacuation ducts and their terminals;  type C43 boilers including their connection ducts but without the chimney which is erected as a shared duct system and which is part of the building;  type C63 boilers, including the connecting piece as specified in 3.7, if not integrated into the boiler;  type C83 boilers, including their connection ducts but without the chimney which is part of the building;  that have a nominal useful heat output below or equal to 70 kW;  where the temperature of the water does not exceed 100 °C during normal operation;  where the maximum water-side operating pressure does not exceed 8 bar. This European Standard is intended to establish specific requirements and test methods for type C atomizing oil burning central heating boilers with respect to construction, safety, fitness for purpose, rational use of energy, classification and marking. This European Standard covers only standard tests. For boilers that produce domestic hot water by a drum or a heat exchanger, integrated or juxtaposed, (by accumulation of instant production), this standard only applies to hot water reheating system components that are not subject to operating conditions applicable to the boiler heating system. This European Standard covers units consisting of boilers equipped with burners that meet the requirements of EN 267, with the following exceptions:  maximum NOx and CO emission values, estimated for boilers according to the classes defined in EN 303-2;  air factor value, defined by the manufacturer and stated in the boiler’s technical specifications;  marking and/or burner data plate which may provide information for the boiler data plate;  installation recommendations for installing the burner on the boiler included in the boiler operating instructions. This European Standard modifies EN 303-1, EN 303-2, EN 304 and specifies supplementary requirements only for room sealed operations.

Heating boilers — Special requirements for oil fired room sealed units up to 70 kW

ICS
97.100.40
CCS
J98
发布
2007-01-31
实施
2007-01-31

This European Standard applies to oil-fired heating boilers, which are declared by the manufacturer to be condensing boilers up to a nominal heat output of 1 000 kW supplied as a unit with an atomizing oil burner which meets the requirements of EN 267. NOTE This European Standard defines three classes of oil fired boilers with efficiency requirements higher than those given for low temperature boilers in the Boiler Efficiency Directive (BED) 94/42/EEC. This European Standard completes/modifies EN 303-1, EN 303-2 and EN 304 and specifies supplementary requirements for condensing boilers.

Heating boilers - Condensing heating boilers for fuel oil; English version of DIN EN 15034:2007-01

ICS
97.100.40
CCS
J98;Q83
发布
2007-01
实施

This European Standard applies to oil-fired heating boilers, which are declared by the manufacturer to be condensing boilers up to a nominal heat output of 1 000 kW supplied as a unit with an atomizing oil burner which meets the requirements of EN 267. This European Standard completes/modifies EN 303-1, EN 303-2 and EN 304 and specifies supplementary requirements for condensing boilers.

Heating boilers - Condensing heating boilers for fuel oil

ICS
97.100.40
CCS
Q83;J98
发布
2006-11-30
实施
2006-11-30

1 Domaine d'application 1.1 Cette norme s'applique aux appareils de chauffage à air chaud pulsé devant être installés dans des logements mobiles et des véhicules de camping, quels que soient leur puissance calorifique et le type de brûleur utilisé. 1.2 Cette norme s'applique aux appareils dont l'alimentation en combustible peut être distante ou intégrée à l'appareil. 1.3 Dans les normes CSA, le terme «doit» indique une exigence, c'est-à-dire une prescription que l'utilisateur doit respecter pour assurer la conformité à la norme ; «devrait» indique une recommandation ou ce qu'il est conseillé mais non obligatoire de faire et «peut», une possibilité ou un conseil. Les notes qui accompagnent les articles ne comprennent pas de prescriptions ni de recommandations. Elles servent à séparer du texte les explications ou les renseignements qui ne font pas proprement partie de la norme. Les notes au bas des figures et des tableaux font partie de ceux-ci et peuvent être rédigées comme des prescriptions. Les légendes des figures et des équations font également partie de celles-ci. Les annexes peuvent être normatives (obligatoires) ou informatives (facultatives). 1.4 Dans cette norme, les valeurs sont exprimées en unités SI (métriques). Les valeurs entre parenthèses ne sont fournies qu'à titre de renseignement.

Hot air oil heaters for mobile homes and RVs

ICS
97.100.40
CCS
发布
2006-07-01
实施

This European Standard applies to type CX3 central heating boilers as specified in 4.1, equipped with atomizing oil burners: type C13, type C33, and type C53 boilers, including their combustion air supply and combustion products evacuation ducts and their terminals; type C43 boilers including their connection ducts but without the chimney which is erected as a shared duct system and which is part of the building; type C63 boilers, including the connecting piece as specified in 3.7, if not integrated into the boiler;type C83 boilers, including their connection ducts but without the chimney which is part of the building;that have a nominal useful heat output

Heating boilers - Special requirements for oil fired room sealed units up to 70 kW

ICS
97.100.40
CCS
发布
2006
实施

This European Standard applies to oil-fired heating boilers, which are declared byThe manufacturer to becondensing boilers up to a nominal heat output of 1 000 kW supplied as a unit with an atomizing oil burner whichmeetsThe requirements of EN 267.

Heating boilers - Condensing heating boilers for fuel oil

ICS
97.100.40
CCS
发布
2006
实施

These requirements apply to oil-burning flue-connected room heaters and ranges as defined herein. They may be used where a competent attendant will not be constantly on duty in the room where the appliance is located, while the appliance is in operation. They are required to be equipped with automatic primary safety controls to prevent abnormal discharge of oil at the burner in case of ignition failure or flame failure. They are not intended for use in spaces in which flammable vapors or gases may be present.

Standard for Safety for Oil-Burning Stoves

ICS
97.100.40
CCS
Q83
发布
2005-01-01
实施

These requirements apply to oil-fired floor furnaces.Requirements for the installation and use of oil-burning equipment are included in the Standard for the Installation of Oil-Burning Equipment, ANSI/NFPA 31. Requirements for the installation of oil-burning equipment are also included in codes such as the BOCA Basic National Mechanical Code, the Standard Mechanical Code, and the Uniform Mechanical Code.

CSDS 11/4/05 (6p)

ICS
97.100.40
CCS
发布
2005-01-01
实施

These requirements cover air-heating appliances of the central furnace and unit heater types intended for burning waste oil fuels and having fuel inputs rated no more than 20 gallons/hour (75.7 liters/hour) or approximately 3, 000, 000 Btu/hour (3, 160, 000 kj/hour). These requirements also cover automatically-lighted, mechanical-atomizing type burners that typically are used with these appliances. The burner is to be factory-installed on or provided with each appliance