C48 医用卫生用品 标准查询与下载



共找到 424 条与 医用卫生用品 相关的标准,共 29

This part of EN 455 specifies requirements for the evaluation of biological safety for medical gloves for single use. It gives requirements for labelling and the disclosure of information relevant to the test methods used.

Medical gloves for single use — Part 3: Requirements and testing for biological evaluation

ICS
11.140
CCS
C48
发布
2007-01-31
实施
2007-01-31

1.1 This test method is used to evaluate the resistance of medical face masks to penetration by the impact of a small volume (~2 mL) of a high velocity stream of synthetic blood. Medical face mask pass/fail determinations are based on visual detection of synthetic blood penetration.1.2 This test method does not apply to all forms or conditions of blood-borne pathogen exposure. Users of the test method must review modes for face exposure and assess the appropriateness of this test method for their specific application.1.3 This test method primarily addresses the performance of materials or certain material constructions used in medical face masks. This test method does not address the performance of the medical face masks design, construction, or interfaces or other factors with the potential to affect the overall protection offered by the medical face mask and its operation (such as filtration efficiency and pressure drop). Procedures for measuring these properties are contained in Test Methods F 2101 and MIL-M-36954C.1.4 This test method does not address breathability of the medical face mask materials or any other properties affecting the ease of breathing through the medical face mask. This test method evaluates medical face masks as an item of protective clothing. This test method does not evaluate the performance of medical face masks for airborne exposure pathways or in the prevention of the penetration of aerosolized body fluids deposited on the medical face mask.1.5 The values stated in SI units or inch-pound units are to be regarded separately as standard. The pressure values stated in each system are not exact equivalents. However, as the corresponding velocities are within 1 % of each other, (see X1.4.2), reporting of the results in either units is permitted.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Resistance of Medical Face Masks to Penetration by Synthetic Blood (Horizontal Projection of Fixed Volume at a Known Velocity)

ICS
11.120.20 (Wound dressings. Compresses)
CCS
C48
发布
2007
实施

1.1 This test method is designed to evaluate the potential of glove materials under test to induce and elicit Type IV skin sensitization reactions (that is, allergic contact dermatitis) in humans.1.2 This test method should be used by individuals experienced in or under the supervision of those experienced in the use of good clinical practice procedures.1.3 During the performance of the Human Repeat Insult Patch Test (RIPT) for determining sensitization, investigators are confronted with skin responses that represent skin irritation (non-immunologic responses) or allergic contact dermatitis (ACD). The numerical scoring system for grading the intensity of both are similar and test facilities may vary in their scores that describe intensities of allergic and irritant skin responses. The hallmark of a mild allergic contact dermatitis is a sustained palpable erythematous reaction. Delayed-type allergic contact reactions from patch tests have intensity characteristics that favor scores of higher values for longer periods of time and typically do not produce a minimal score (score of 1, a just-perceptible erythema) for short durations (less than 48 h). It is the responsibility of the investigator to evaluate the scores in light of irritant reactions so that the responses are allergic in nature and not irritant. The investigator should denote a final score as either due to contact allergy or irritation. Paragraphs 9.5-9.5.5 describe a commonly used scoring system and discuss allergic and irritant responses in detail.1.4 The Draize RIPT was published in 1944 as an attempt to decrease the frequency ACD. The test techniques at that time were just being validated and this experimental design was largely empiric. The principle of the test is as follows:1.4.1 Multiple inductions of the study material at relatively non or low irritancy levels,1.4.2 Approximately a two-week rest period, and1.4.3 A standard diagnostic challenge of approximately 48 h and a delayed reading at approximately 96 h after patch application.1.5 In the intervening years, with further experimentation added to this empiric approach, three additional principles have been learned:1.5.1 Increasing the concentration of the study material,1.5.2 Defining a no effect level (this is possible with only individual ingredients and not the final study material), and 1.5.3 The enhanced sensitivity and the use of occlusion (where occlusion would not ordinarily be present).1.6 In 1945, Henderson and Riley demonstrated that a test panel sample size of 30 000 subjects would have to be employed to ensure statistically that there would be no more than 0.1 % sensitization. If there are no allergic responses in a test panel of 200 subjects with exposures comparable to those of the population, then there could be as many as 1.5 allergic reactions per 100 users.1.7 All medical devices must be safe and effective for their intended use. Since medical devices such as gloves come in contact with human tissue, they should be tested for biocompatibility in animals first. The human repeat insult patch test (RIPT) is one test that can be used to test rubber gloves for skin sensitization to chemicals used in the manufacture of gloves.1.7.1 Since various forms of the RIPT exist, a single standardized test method that outlines the testing protocol, scoring system, and the criteria for skin sensitization should be developed.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Human Repeat Insult Patch Testing of Medical Gloves

ICS
11.140 (Hospital equipment)
CCS
C48
发布
2007
实施

이 규격은 의료용으로 사용하는 봉합침(이하 봉합침이라 한다.)에 대하여 규정한다.

Surgical needles suture

ICS
11.040.40
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 환자에게 투여하는 가스 중의 산소 농도 또는 환자가 호출하는 가스 중의 산소

Oxygen analyzers for medical use

ICS
11.040.10
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 병원의 수술실에서 사용하는 무영등에 대하여 규정한다.

Shadowless lamp

ICS
11.040.01
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 의료용으로 사용하는 붕대에 대하여 규정한다.

Bandage

ICS
11.120.20
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 병원, 구급차, 학교, 공장 등에서 환자의 구급을 위한 운반에 사용하는 들것(이

Holding stretchers

ICS
13.340.00
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 의료용으로 사용하는 동맥류 침에 대하여 규정한다.

Aneurism needles

ICS
11.040.20
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 의료용으로 사용하는 결찰사 유도기에 대하여 규정한다.

Ligature carrier

ICS
11.040.20
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 안과에서 사용하는 퍼셉스(이하 퍼셉스라 한다.)에 대하여 규정한다.

Eye forceps

ICS
11.040.70
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 장선 봉합사(이하 장선이라 한다.)에 대하여 규정한다.

Surgical sutures catgut

ICS
11.040.00
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 의료용 설압자에 대하여 규정한다.

Tongue depressors

ICS
29.060.10
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 의료용으로 사용하는 비후용 세정관(이하 세정관이라 한다.)에 대하여 규정한다.

Cannula for maxillary antrum and frontal sinus

ICS
11.040.20
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 소식자에 대하여 규정한다.

Probes

ICS
11.040.00
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 유아용 보육에 사용하는 포유병에 대하여 규정한다.

Feeding bottles

ICS
11.040.40
CCS
C48
发布
2006-12-29
实施
2006-12-29

이 규격은 세균 배양에 사용하는 세균 배양기(의료용 배양기, 이하 배양기라 한다.)에 대하

Incubator

ICS
11.100
CCS
C48
发布
2006-12-08
实施
2006-12-08

이 규격은 환자가 공기를 자연스럽게 코로 호흡했을 때 비강에 생기는 압력 및 유량을 검출해

Rhinomanometers

ICS
11.040.10
CCS
C48
发布
2006-12-08
实施
2006-12-08

이 규격은 산소 결핍의 우려가 있는 우물, 입갱, 굴, 잠함, 피트, 맨홀, 정화조, 암거

Oxygen indicator/alarm

ICS
11.040.10
CCS
C48
发布
2006-11-01
实施
2006-11-01

이 규격은 사무실, 공장, 지하 거리 등의 자연 환기 및 인공 환기에서의 공기 흐름의 속도

Anemometer for general use

ICS
13.320
CCS
C48
发布
2006-11-01
实施
2006-11-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号